Indledning
The Renogy Monitoring Screen is a high-precision meter designed specifically for the Renogy Smart Lithium Iron Phosphate Battery Series. It provides accurate and real-time data by communicating directly with the battery management system (BMS), eliminating the need for a traditional shunt. This manual provides detailed instructions for the setup, operation, and maintenance of your monitoring screen.

Image: The Renogy Monitoring Screen connected to a Smart Lithium Iron Phosphate Battery, illustrating its primary function.
Produkt overview
The monitoring screen features a clear LCD display and intuitive controls for easy access to battery information.

Image: Diagram illustrating the key components of the Renogy Monitoring Screen, including the LCD, control buttons, and communication port.
- LCD skærm: Displays various battery parameters.
- Side ned-knap: Navigates through display pages.
- Side op-knap: Navigates through display pages.
- Power knap: Used for power control and shelf mode activation.
- Front Cover Plate: Beskyttende casing.
- RJ45 Communication Port: Connects to the battery's BMS.
Opsætning
The Renogy Monitoring Screen is designed for plug-and-play operation, requiring no complex system configuration or calibration.
Installationstrin
- Forbered monteringsoverfladen: Choose a flat, stable surface near your Smart Lithium Iron Phosphate Battery.
- Fjern frontdæksel: Carefully detach the front cover plate from the monitoring screen.
- Markér borepunkter: Use the monitoring screen as a template to mark the four screw holes on your chosen surface.
- Sikr skærmen: Mount the monitoring screen to the surface using the provided M2.9 x 13 screws.
- Reattach Front Cover: Snap the front cover plate back onto the secured monitoring screen.

Image: Step-by-step visual guide for mounting the monitoring screen.
Tilslutning til batteri
Connect the monitoring screen directly to your Renogy Smart Lithium Iron Phosphate Battery using the included RJ45 communication cable.
- Insert one end of the RJ45 communication cable into the RJ45 Communication Port on the back of the monitoring screen.
- Insert the other end of the RJ45 communication cable into the RS485 Up Communication Port on your Renogy Smart Lithium Iron Phosphate Battery.

Image: Illustration of the simple plug-and-play connection between the monitoring screen and the battery using an RJ45 cable.
Betjeningsvejledning
Once connected, the monitoring screen will automatically power on and begin displaying battery information. Use the Page Up and Page Down buttons to navigate through different display screens.
Vis information
The screen provides comprehensive data about your battery bank's status:

Image: Visual representation of the detailed battery information available on the monitoring screen.
- Nuværende Voltage: Nuværende voltage af batteribanken.
- Present Current: Current flowing in or out of the battery bank.
- Remaining Capacity (AH): Tilgængelig amp-hours in the battery bank.
- State of Charge (SoC%): Procenttage tilbageværende.
- Resterende tid: Estimated time until the battery is fully discharged or charged at current load/charge rate.
- Advarselskode: Displays codes for abnormal conditions (see Troubleshooting section).
- Number of Paralleled Batteries: Indicates how many batteries are connected in parallel.
- Batteriniveau: Graphical representation of battery charge.
- Selvopvarmningsfunktion: Indication for compatible batteries.
Battery Bank Monitoring
The screen monitors the charging and discharging process of parallel battery banks with inter-battery communication enabled.

Image: The monitoring screen actively displaying data from a setup with two parallel Renogy Smart Lithium Iron Phosphate Batteries.
Særlige funktioner
Battery Shelf Mode
To preserve power when the battery or battery bank is not in use for an extended period, you can switch it to shelf mode.
- To activate shelf mode, press and hold the Power Button for 3 seconds.
- The screen will indicate when shelf mode is active.
- To exit shelf mode, press the Power Button again.

Image: Demonstrates how to activate the battery shelf mode by holding the power button for three seconds.
Opretholdelse
The Renogy Monitoring Screen requires minimal maintenance. Keep the screen clean and free from dust and moisture. Use a soft, dry cloth for cleaning. Do not use abrasive cleaners or solvents.
- Ensure the RJ45 communication cable is securely connected at all times.
- Periodically check for any physical damage to the screen or cable.
- Opbevar enheden et tørt sted, når den ikke er i brug i længere perioder.
Fejlfinding
The monitoring screen provides warning codes to help identify and address potential issues with your battery bank. Refer to the table below for common warning codes and their meanings.

Image: A comprehensive table detailing various error codes displayed on the monitoring screen and their corresponding battery status descriptions.
| Fejlkode | Batteristatus |
|---|---|
| 01 | Battery High Temp Warning (Charge / Discharge) |
| 02 | Battery Low Temp Warning (Charge) |
| 03 | Battery Low Temp Warning (Discharge) |
| 04 | Over-bindtage Protection (Battery / Battery Cell) |
| 05 | Batteri Under-Voltage Advarsel |
| 06 | Advarsel om opladning for overstrøm |
| 07 | Advarsel om afladning for overstrøm |
| 08 | Battery High Temp Protection (Charge) |
| 09 | Battery Low Temp Protection (Charge) |
If you encounter a warning code, refer to this table to understand the issue. For persistent problems or issues not listed, please contact Renogy customer support.
Specifikationer
| Parameter | Værdi |
|---|---|
| Mærke | Renogy |
| Model | RMS-LFPS-US |
| Produktdimensioner | 7.01 x 11 x 3.18 cm |
| Varens vægt | 63.5 g (0.14 pund) |
| Voltage | 12 Volts (DC Min. Operating) |
| Farve | Sort |
| Måletype | Voltmeter |
| Øverste temperaturvurdering | 113 grader Fahrenheit |
| UPC | 810009714323 |

Image: The monitoring screen displaying voltage, highlighting its primary measurement capability.
Garanti og support
For garantioplysninger og teknisk support henvises til den officielle Renogy website or contact their customer service directly. Ensure you have your product model number (RMS-LFPS-US) and purchase details available when seeking support.
Renogy is committed to providing reliable renewable energy products and support for energy independence.
Renogy Officiel Webwebsted: www.renogy.com