OJ Electronics UDG4-4999-B

OJ Microline UDG4-4999 Termostat Brugermanual

Programmable Thermostat for Radiant Floor Heating Systems

1. Introduktion

This manual provides detailed instructions for the installation, operation, and maintenance of your OJ Microline UDG4-4999 Touch Screen Programmable Thermostat. Designed for electric radiant floor heating systems, this thermostat features dual voltage (120V/240V) and dual sensing (air/floor) capabilities, along with a built-in Class A GFCI for enhanced safety. Please read this manual thoroughly before installation and use to ensure proper function and safety.

OJ Microline UDG4-4999 Thermostat front view

Figur 1: Forside view of the OJ Microline UDG4-4999 Thermostat, displaying its intuitive touch screen interface.

2. Sikkerhedsoplysninger

ADVARSEL: Risk of electric shock. Installation must be performed by a qualified electrician in accordance with local electrical codes. Disconnect power at the circuit breaker before installing or servicing the thermostat.

3. Opsætning og installation

The UDG4-4999 thermostat is designed for easy installation in a standard electrical box. It supports both 120V and 240V systems and includes a floor sensor for precise temperature control.

3.1 Udpakning og komponenter

Carefully remove the thermostat and its components from the packaging. The package should include:

3.2 Ledningsinstruktioner

Follow the wiring diagram below for correct installation. Ensure all connections are secure and comply with local electrical codes. The thermostat requires a dedicated circuit.

Wiring diagram for OJ Microline UDG4-4999 Thermostat

Figure 2: Technical specifications and wiring diagram for the UDG4-4999 Thermostat. Note the connections for Neutral, Hot from power source, and House Ground.

  1. Sluk for strømmen ved hovedafbryderen.
  2. Connect the power supply wires (Line/Load) to the appropriate terminals on the thermostat as indicated in the wiring diagram.
  3. Connect the floor heating cable wires to the designated heating load terminals.
  4. Connect the floor sensor wires to the sensor terminals. Ensure the sensor is properly placed in the floor according to heating system manufacturer guidelines.
  5. Fastgør termostaten til elboksen med de medfølgende skruer.
  6. Gendan strømmen ved afbryderen.

4. Betjeningsvejledning

The UDG4-4999 thermostat features an intuitive 3.5" responsive touch color screen for easy operation and programming.

4.1 Initial Setup and Install Wizard

Upon first power-up, the thermostat will guide you through an Install Wizard to set basic parameters such as date, time, temperature units, and floor type.

4.2 Basic Temperature Adjustment

From the main screen, you can easily adjust the setpoint temperature using the up and down arrows. The thermostat will temporarily override any active program until the next scheduled event.

Hand adjusting temperature on thermostat screen

Figure 3: A hand interacting with the thermostat screen to adjust the temperature setpoint.

4.3 Programming the Thermostat

The thermostat offers a 7-day programmable schedule with multiple events per day to optimize comfort and energy savings. Access the programming menu via the main screen's menu button.

4.4 Avancerede funktioner

5. Vedligeholdelse

The OJ Microline UDG4-4999 thermostat requires minimal maintenance.

6. Fejlfinding

Hvis du oplever problemer med din termostat, kan du se følgende almindelige problemer og løsninger:

ProblemMulig årsagLøsning
Termostatens skærm er blank.No power, tripped circuit breaker, or loose wiring.Check circuit breaker. Ensure wiring connections are secure. Contact a qualified electrician if problem persists.
Varmesystemet tænder ikke.GFCI tripped, thermostat in OFF mode, or wiring issue.Press the GFCI 'Reset' button. Check thermostat mode. Verify wiring.
Temperaturen er unøjagtig.Floor sensor issue or improper placement.Ensure floor sensor is correctly installed and not damaged.
Cannot turn the thermostat completely OFF for summer.Thermostat may not have a dedicated 'OFF' button for the heating function, or it's in a continuous program mode.Set the thermostat to Vacation Mode with a very low setpoint, or use the 'OFF' setting if available in the menu. For complete power disconnection, turn off the dedicated circuit breaker.

7. Specifikationer

FeatureDetalje
ModelnummerUDG4-4999-B
Voltage120V / 240V AC
Maksimal belastning15 Amps (1800W@120V, 3600W@240V)
GFCIClass A (5mA trip level)
Temperaturkontrol typeGulvvarme
SensingDual Sensing (Air & Floor)
Floor Limit Range+41 til +104°F (+5 til +40°C)
Omgivende temperaturområde+32 til +104°F (0 til +40°C)
Display Type3.5 tommer berøringsskærm
ForbindelsesteknologiKablet
MonteringstypeVægmontering
CertificeringerC-UL-us Listed, Certified for Wet Room installations
DimensionerCa. 6 x 3.5 x 2.6 tommer
Varens vægt12.8 ounce

8. Garanti og support

8.1 Limited Factory Warranty

The OJ Microline UDG4-4999 Thermostat comes with a 3-Year limited factory WarrantyDenne garanti dækker materiale- og fabrikationsfejl ved normal brug. Gem venligst din købsbevis i tilfælde af garantikrav.

8.2 Kundesupport

For technical assistance, troubleshooting beyond this manual, or warranty inquiries, please contact OJ Electronics customer support. Refer to the official OJ Electronics webhjemmeside for de seneste kontaktoplysninger.

Relaterede dokumenter - UDG4-4999-B

Preview OJ Microline UTN4-4999 Termostat til elektrisk gulvvarme | OJ Electronics
Udforsk OJ Microline UTN4-4999, en elegant og intuitiv termostat til elektrisk gulvvarme. Funktionerne omfatter energilogning, gulvbeskyttelse, jordfejlsikring og detaljerede tekniske specifikationer. Ideel til installationer i private hjem.
Preview OJ Electronics UDG/UDG/UTN/USG termostat brugermanual og installationsvejledning
Bruger- og installationsvejledning til OJ Electronics UDG, UDG, UTN, USG termostater. Dækker installation, programmering, betjening, HFI-sikkerhed og fejlfinding for elektriske gulvvarmesystemer.
Preview UDG4 Touch Thermostat Interactive User Manual
Explore the features and operation of the OJ Electronics UDG4 Touch Thermostat with this interactive user manual. Learn to program schedules, manage settings, and optimize your home's heating for comfort and energy efficiency.
Preview UWG5 WiFi LED Touch Termostat Brugermanual - OJ Electronics
Omfattende brugermanual til OJ Electronics UWG5 WiFi LED Touch-termostaten. Lær om opsætning, funktioner, smart home-integration med Alexa og Google, fejlfinding og meget mere.
Preview OJ Electronics MCD3-1999-UAE6 Digital Termostat Instruktioner
Brugermanual og installationsvejledning til OJ Electronics MCD3-1999-UAE6 digital termostat, der dækker opsætning, betjening, sikkerhed og tekniske specifikationer for elektrisk gulvvarme.
Preview OJ Electronics UWG4/AWG4 WiFi Touch-termostat Hurtigstartguide
Lynvejledning til OJ Electronics UWG4/AWG4 WiFi Touch-termostaten, der dækker installation, opsætning og grundlæggende betjening af gulvvarmesystemer.