Leviton LB260-GS

Leviton 60A 2-Pole Plug-On Smart GFCI Branch Circuit Breaker (LB260-GS) Instruction Manual

Model: LB260-GS

1. Introduktion

This manual provides essential information for the safe and effective installation, operation, and maintenance of your Leviton LB260-GS 60A 2-Pole Plug-On Smart GFCI Branch Circuit Breaker. Please read all instructions carefully before proceeding with installation or use.

The Leviton LB260-GS is a Smart Ground Fault Circuit Interrupter (GFCI) branch circuit breaker designed for use in Leviton Load Centers. It features hydraulic magnetic technology for reliable operation across a wide temperature range and integrates with the My Leviton app for enhanced monitoring and control.

2. Sikkerhedsoplysninger

WARNING: RISK OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH.

  • This product must be installed and serviced by qualified electrical personnel only.
  • Turn off all power to the electrical panel before working on or installing the circuit breaker.
  • Brug altid en voltage detector to confirm power is off before touching any wires or components.
  • Follow all local and national electrical codes and regulations.
  • Brug ikke denne enhed, hvis den ser beskadiget ud.

Manglende overholdelse af disse instruktioner vil resultere i dødsfald eller alvorlig personskade.

3. Produktet er slutview

The Leviton LB260-GS is a 2-pole, 60-Amp Smart GFCI circuit breaker. It is designed to protect against ground faults, which can cause severe electrical shock. Its hydraulic magnetic trip technology ensures consistent performance from -40°C to 85°C (-40°F to 185°F).

Leviton LB260-GS 60A 2-Pole Smart GFCI Circuit Breaker, front view

Billede 3.1: Front view of the Leviton LB260-GS Smart GFCI Circuit Breaker. Shows the ON/OFF switch, 60 Amp rating, GFCI indicator, and wireless communication symbol.

Leviton LB260-GS 60A 2-Pole Smart GFCI Circuit Breaker, side view

Billede 3.2: Side view of the Leviton LB260-GS Smart GFCI Circuit Breaker, illustrating its compact design for plug-on installation.

Leviton LB260-GS 60A 2-Pole Smart GFCI Circuit Breaker, rear view showing bus connections

Billede 3.3: Bag view of the Leviton LB260-GS Smart GFCI Circuit Breaker, highlighting the plug-on bus connections for easy installation into a Leviton Load Center.

Nøglefunktioner:

  • Smart integration: Connects with the My Leviton app for energy consumption data, enhanced safety alerts, and remote control.
  • Nem installation: Revolutionary plug-on design allows for quick and tool-free installation into Leviton Load Centers.
  • Hydraulic Magnetic Technology: Ensures precise and reliable tripping characteristics across a wide temperature range without derating.
  • Forbedret sikkerhed: Features patented reset lockout technology, preventing reset if ground fault protection is compromised.

4. Opsætning og installation

Professional installation by a qualified electrician is required.

  1. Prepare the Load Center: Ensure all power to the Leviton Load Center is turned OFF at the main service disconnect. Verify with a voltage tester.
  2. Ledningsforbindelser: The Leviton Load Center design allows branch phase and neutral connections to be made directly on the panel bus bars without the circuit breaker present. Land the branch circuit wires (hot and neutral) to the appropriate terminals on the load center bus.
  3. Install the Breaker: Align the LB260-GS circuit breaker with the desired position on the load center bus. Firmly push the breaker onto the bus until it clicks into place. No additional wiring to the breaker itself is required.
  4. Jordledning: Connect the ground wire from the branch circuit to the ground bar in the load center.
  5. Bekræft installationen: Dobbelttjek alle forbindelser for tæthed og korrekt montering.
  6. Gendan strøm: Once installation is complete and verified, restore power to the load center.

For a visual guide on installing Leviton Load Centers and circuit breakers, please refer to the video below:

Video 4.1: An instructional video demonstrating the installation process for Leviton Load Centers and their plug-on circuit breakers, including wiring and breaker placement.

5. Betjeningsvejledning

Manuel betjening:

  • Tænder: Push the breaker handle firmly to the "ON" position.
  • Slukker: Push the breaker handle firmly to the "OFF" position.
  • Nulstilling af en udløst afbryder: If the breaker trips, the handle will move to a center position. To reset, first push the handle firmly to the "OFF" position, then push it to the "ON" position. If the breaker immediately trips again, there may be an electrical fault that needs to be addressed.

GFCI Test and Reset:

The GFCI function should be tested monthly to ensure proper operation.

  1. Sørg for, at afbryderen er i "ON"-positionen.
  2. Press the "TEST" button on the face of the breaker. The breaker should immediately trip to the center position.
  3. To restore power, push the handle firmly to the "OFF" position, then to the "ON" position.
  4. If the breaker does not trip when the "TEST" button is pressed, or if it does not reset, the GFCI function may be faulty. Contact a qualified electrician for inspection and replacement.

Smart Features (My Leviton App):

The LB260-GS integrates with the My Leviton app, providing advanced functionality:

  • Energiovervågning: View real-time and historical energy consumption data for the circuit.
  • Fjernbetjening: Turn the breaker ON or OFF remotely via the app.
  • Meddelelser: Receive alerts for electrical anomalies, tripped breakers, or other status changes.
  • Selv test: The smart breaker performs self-tests and reports status to the app.

Refer to the My Leviton app documentation for detailed instructions on connecting and utilizing smart features.

6. Vedligeholdelse

  • Månedlig GFCI-test: Perform the GFCI test as described in Section 5.
  • Visuel inspektion: Periodically inspect the circuit breaker for any signs of physical damage, discoloration, or loose connections. If any issues are observed, contact a qualified electrician.
  • Rensning: Keep the breaker and surrounding area clean and free of dust and debris. Do not use liquid cleaners directly on the breaker.

7. Fejlfinding

ProblemMulig årsagLøsning
Breaker rejser ofte.Overload, short circuit, or ground fault.Reduce load on the circuit. Check for damaged appliances or wiring. If it's a GFCI trip, check for ground faults in connected equipment. Contact an electrician if the problem persists.
Breaker does not reset after tripping.Persistent fault (overload, short circuit, or ground fault) or internal breaker damage.Ensure the handle is pushed fully to "OFF" before attempting to reset to "ON". If it still won't reset, a fault is likely present. Do not force the breaker. Contact a qualified electrician.
GFCI test button does not trip the breaker.Defekt GFCI-mekanisme.The breaker may be defective. It must be replaced by a qualified electrician.
No data in My Leviton app / Breaker not connecting.Network issue, app configuration error, or data hub issue.Ensure your Wi-Fi network is active and the Leviton data hub (if applicable) is connected. Check app settings and follow in-app troubleshooting guides.

For issues not covered here, contact Leviton customer support or a qualified electrician.

8. Specifikationer

AttributDetalje
MærkeLeviton
ModelnummerLB260-GS
Nuværende vurdering60 Amps
Antal poler2
Voltage120 / 240 VAC
Afbryder typeGFCI (Ground Fault Circuit Interrupter)
Trip TechnologyHydraulic Magnetic
Afbryd vurdering10 KA
MonteringstypePanel Mounting (Plug-On)
Driftstemperatur-40°C til 85°C (-40°F til 185°F)
Dimensioner4 x 2.5 x 3.9 tommer (ca.)
Vægt13.6 ounce
UPC078477815342

9. Garanti og support

Garanti:

This Leviton product is covered by a 10 års begrænset garanti. For full details regarding warranty terms and conditions, please refer to the official Leviton warranty statement available on their webwebsted eller kontakt kundesupport.

Kundesupport:

For technical assistance, product information, or warranty claims, please contact Leviton customer support through their official webwebstedet eller de kontaktoplysninger, der følger med din produktemballage.

You can visit the official Leviton website for more resources: www.leviton.com

Relaterede dokumenter - LB260-GS

Preview Leviton GFNT1-DIN/GFNT2-DIN DIN-skinnemonteret GFCI-stikkontakt installationsvejledning
Omfattende vejledning til installation og test af Levitons GFNT1-DIN og GFNT2-DIN DIN-skinnemonterede GFCI-stikkontakter, inklusive ledningsføringsinstruktioner, sikkerhedsforanstaltninger og fejlfinding.
Preview Leviton GFCI-stikkontakt med USB-porte Installations- og betjeningsmanual
Omfattende vejledning til installation og betjening af Leviton HFI-stikkontakter med USB-porte, inklusive ledningsføringsinstruktioner, sikkerhedsadvarsler, testprocedurer og garantioplysninger.
Preview Leviton GFCI-stikkontaktinstallations- og testvejledning
En omfattende vejledning til installation og test af en Leviton SmartLock Pro GFCI-stikkontakt, inklusive ledningsføringsinstruktioner, sikkerhedsforanstaltninger og fejlfindingstips.
Preview Installation og test af Leviton Smart GFCI-stikkontakt: En omfattende guide
Trinvise instruktioner til installation og test af Leviton Smart GFCI-stikkontakter (modeller D2GF1, D2GF2). Lær om GFCI-funktionalitet, ledningsføring, fejlfinding og sikkerhedsforanstaltninger.
Preview Leviton Load Center Phase Maps Installation Guide
This guide provides phase map illustrations to simplify the installation of the Leviton Whole Home Energy Monitor (LWHEM). It details where to terminate power wires and mount the Smart Mains Metering Accessory CTs for monitoring whole-home energy consumption.
Preview Leviton Load Center Enclosure Installation Instructions
Detailed installation instructions for Leviton Load Center Enclosures, models LP2xx, LP3xx, LP4xx, and LP6xx. Covers safety, knockout removal, mounting, wiring, branch circuit breaker installation, and cover fitting.