This manual provides essential information for the proper installation, operation, and maintenance of your CFS Compatible TFC-RS9-50 Reverse Osmosis Membrane Filter. This filter is designed as a compatible replacement for various RainSoft RO Systems, including models #21176, 9598, UF50, 21179, 9757, UF50T, UF50TCB, and UF50TCBVOC.

It replaces RainSoft parts #12447, 18644, 18571, 17370, 12448, 13018, and 17374. The membrane is constructed from polyamide thin film composite, engineered for effective water filtration.

CFS Compatible TFC-RS9-50 Reverse Osmosis Membrane Filter

Image 1.1: CFS Compatible TFC-RS9-50 Reverse Osmosis Membrane Filter. This image shows the blue cylindrical membrane filter with its internal layers visible at one end, indicating its construction.

Nøglefunktioner:

  • Kompatibilitet: Designed to fit RainSoft RO Systems #21176, 9598, UF50, 21179, 9757, UF50T, UF50TCB, UF50TCBVOC.
  • Materiale: Polyamide Thin Film Composite for efficient filtration.
  • Erstatning for: RainSoft Part # 12447, 18644, 18571, 17370, 12448, 13018, 17374.
  • Levetid: Typically lasts up to 4 years, depending on water usage and quality.

2. Specifikationer

AttributDetalje
MærkeCFS
ModelnummerTFC R9 50
MaterialePolyamide Thin Film Composite
Produktdimensioner9.5 x 2 x 9.5 tommer
Varens vægt6.4 ounce
Ekstern testcertificeringNSF
ProduktfordeleEffectively filters water for up to 4 years
UPC045399090447

3. Installation (Opsætning)

Proper installation is crucial for the optimal performance of your RO membrane filter. Always refer to your specific RainSoft RO System's manual for detailed instructions on accessing and replacing the membrane housing. The following are general steps:

  1. Sikkerhed først: Turn off the water supply to your RO system and relieve system pressure by opening the RO faucet.
  2. Locate Membrane Housing: Identify the RO membrane housing, typically a larger cylindrical housing compared to pre-filters.
  3. Fjern den gamle membran: Unscrew the cap of the membrane housing. Carefully pull out the old membrane using pliers if necessary.
  4. Rent hus: Clean the inside of the membrane housing thoroughly with a mild soap solution and rinse well.
  5. Prepare New Membrane: Remove the new CFS TFC-RS9-50 membrane from its packaging. Ensure the O-rings are properly seated on the membrane.
  6. Indsæt ny membran: Insert the new membrane into the housing with the end containing the two O-rings going in first. Push firmly until it is fully seated.
  7. Sikker bolig: Screw the cap back onto the membrane housing, hand-tightening it securely. Do not overtighten.
  8. Genopret vandforsyningen: Slowly turn on the water supply to the RO system. Check for any leaks.
  9. Skyllesystem: Allow the system to fill and then flush the new membrane by running the RO faucet for at least 24 hours (or as recommended by your RO system manufacturer) to remove any manufacturing preservatives. Discard this initial water.

Note: Some RainSoft systems may have specific procedures for membrane replacement. Consult your system's original manual for precise steps.

4. Betjening

Once installed and flushed, your CFS TFC-RS9-50 Reverse Osmosis Membrane Filter operates automatically as part of your RainSoft RO system. The membrane works by allowing water molecules to pass through its semi-permeable surface while rejecting dissolved solids, contaminants, and impurities, which are then sent to the drain.

Normal drift:

  • The system will produce purified water, which is stored in the RO storage tank.
  • When the RO faucet is opened, purified water is dispensed from the storage tank.
  • The system will automatically refill the storage tank as water is used.

Vigtig: The performance of the RO membrane is dependent on the quality of the incoming water and the proper functioning of pre-filters (sediment and carbon filters). Ensure these are replaced regularly according to your system's maintenance schedule.

5. Vedligeholdelse

The CFS TFC-RS9-50 Reverse Osmosis Membrane Filter is designed for long-lasting performance, typically up to 4 years. However, its lifespan can vary based on the quality of your source water and the frequency of use. Regular maintenance of your entire RO system is essential.

Anbefalet vedligeholdelse:

  • Pre-filter Replacement: Sediment and carbon pre-filters should be replaced every 6-12 months to protect the RO membrane from premature fouling.
  • Udskiftning af RO-membran: Replace the RO membrane every 2-4 years, or sooner if you notice a significant drop in water production, a decline in water quality (e.g., taste, odor), or if your TDS (Total Dissolved Solids) meter indicates high levels.
  • Systemrensning: It is recommended to sanitize your RO system annually during filter changes to prevent bacterial growth.

Tip: Keep a record of filter replacement dates to ensure timely maintenance.

6. Fejlfinding

If you experience issues with your RO system after installing the CFS TFC-RS9-50 membrane, consider the following common troubleshooting steps:

ProblemMulig årsagLøsning
Slow Water Production
  • Lavt indgående vandtryk.
  • Clogged pre-filters.
  • Fouled or old RO membrane.
  • Luft i systemet.
  • Tjek husstandens vandtryk.
  • Udskift forfiltre.
  • Replace RO membrane if old or fouled.
  • Ensure all air is purged from the system after installation.
Poor Water Taste/Odor
  • Expired post-carbon filter.
  • Fouled RO membrane.
  • System not flushed adequately after membrane replacement.
  • Replace post-carbon filter.
  • Replace RO membrane.
  • Flush the system for a longer period (24-48 hours).
Vandlækager
  • Løse forbindelser.
  • Beskadigede O-ringe.
  • Revnet hus.
  • Kontroller og stram alle forbindelser.
  • Inspect and replace O-rings if damaged.
  • Inspect housing for cracks; replace if necessary.

If problems persist, contact a qualified technician or CFS customer support.

7. Garanti og support

CFS (Complete Filtration Services) stands behind the quality of its products. This RO membrane filter is designed for reliable performance. For specific warranty details, please refer to the product packaging or contact CFS directly.

Fabrikant: CFS KOMPLETT FILTRERINGSTJENESTER EST.2006

Varighed af tilgængelighed af reservedele i EU: 2 år

For technical assistance, product inquiries, or support, please visit the official CFS website or contact their customer service department. You can also refer to the general information video about CFS filters below.

Video 7.1: An informational video from CFS (Complete Filtration Services) showcasing their range of water and air filtration products. This video provides a general overview of the brand's commitment to filtration solutions.

CFS Complete Filtration Services Logo

Image 7.1: The logo for CFS Complete Filtration Services, established in 2006.

Relaterede dokumenter - TFC R9 50

Preview CFS Yeti-Anchor™ installationsvejledning: Sikre sandwichpanelforbindelser
Omfattende installationsvejledning til CFS Yeti-Anchor™ sandwichpanelankre. Lær om komponenter, layoutdetaljer, forborede brædder, installationsværktøjer, test og eftermonteringsprocedurer for sikker og effektiv konstruktion.
Preview CFS Yeti-Anchor™ Sandwich Panel Connector: Technical Overview og specifikationer
Comprehensive guide to CFS Yeti-Anchor™ Sandwich Panel Connectors, detailing features, installation, technical specifications, and compatible insulation products like STRATA and PanelTherm for modern construction.
Preview CFS CPRO52S Ankerkanal - Tekniske specifikationer og belastningsdata
Detailed technical specifications, geometry, load data, and material information for the CFS CPRO52S Cold Rolled Anchor Channel, designed for 135mm thick panels.
Preview CFS CPRO52S Ankerkanal - Tekniske specifikationer og belastningsdata
Detaljerede tekniske specifikationer, geometri, belastningsdata og materialeinformation for CFS CPRO52S koldvalsede ankerskinner, designet til 135 mm tykke paneler.
Preview CFS ATA52 Anchor Channel - Technical Specifications and Load Data
Detailed technical specifications, geometry, load data, and material information for the CFS ATA52 Hot Rolled Anchor Channel, designed for maximum strength and increased tolerance.
Preview Instruktioner til filterskift fra APEC RO Systems
Trin-for-trin instruktioner til udskiftning af filtre og membraner i APEC RO-systemer, inklusive Stages 1-3 Forfiltre, Stage-4 Membran, Stage-5/6 Kulstof TCR-filtre, Stage-6 pH-filter og Stage-5 UV-pære. Dækker modellerne ROES-50 (gammel og ny), ROES-PH75 og ROES-UV75, med anbefalede udskiftningsintervaller og vigtige bemærkninger om tilslutninger og desinfektion.