Schneider Electric A9DA2616

Schneider Electric Acti9 iDD40T fejlstrømsafbryder brugermanual

Model: A9DA2616 | Brand: Schneider Electric

1. Introduktion

This manual provides essential information for the safe and effective installation, operation, and maintenance of the Schneider Electric Acti9 iDD40T Residual Current Circuit Breaker (RCBO). The Acti9 iDD40T is designed to protect against electrical shock by detecting earth leakage currents and disconnecting the circuit. Please read this manual thoroughly before installation and use.

2. Sikkerhedsoplysninger

ADVARSEL: Electrical installation and maintenance should only be performed by qualified and authorized personnel. Failure to follow these instructions can result in serious injury or death.

3. Opsætning og installation

The Acti9 iDD40T RCBO is designed for DIN rail mounting. Ensure adequate space for ventilation and wiring.

3.1. Montering

  1. Sørg for, at DIN-skinnen er sikkert installeret i det elektriske kabinet.
  2. Hook the top clip of the RCBO onto the DIN rail.
  3. Press down firmly on the bottom of the RCBO until it clicks into place on the rail.

3.2. Ledningsforbindelser

Refer to the diagram below for correct wiring. Ensure all connections are tight to prevent overheating and arcing.

Schneider Electric Acti9 iDD40T RCBO with wiring terminals and test button

Figure 1: Schneider Electric Acti9 iDD40T RCBO. This image shows the front view of the circuit breaker, highlighting the input and output terminals, the operating handle, and the 'Regular test' button. The 'N' terminal for neutral connection is visible at both the top and bottom.

4. Betjeningsvejledning

4.1. Tænd/sluk

4.2. Test Button Function

The 'Regular test' button (marked 'T' or with a test symbol) is used to verify the proper functioning of the earth leakage detection mechanism.

  1. Ensure the RCBO is in the 'ON' position and the circuit is live.
  2. Press and hold the 'Regular test' button. The RCBO should immediately trip to the 'OFF' position.
  3. Slip knappen.
  4. Reset the RCBO by pushing the handle fully down to 'OFF', then up to 'ON'.
  5. If the RCBO does not trip when the test button is pressed, it may be faulty and should be replaced immediately.

5. Vedligeholdelse

The Acti9 iDD40T RCBO requires minimal maintenance. Regular testing is the primary maintenance activity.

6. Fejlfinding

If you encounter issues with your Acti9 iDD40T RCBO, refer to the following common troubleshooting steps:

ProblemMulig årsagLøsning
RCBO trips immediately after being reset.Persistent earth leakage fault, short circuit, or overload in the protected circuit.Disconnect all loads from the circuit. Reset the RCBO. If it holds, reconnect loads one by one to identify the faulty appliance or wiring. If it still trips with no loads, consult a qualified electrician.
RCBO does not trip when the 'Regular test' button is pressed.Faulty RCBO internal mechanism.The device is faulty and must be replaced by a qualified electrician. Do not attempt to repair.
RCBO trips intermittently.Intermittent earth leakage, transient overloads, or sensitive equipment causing nuisance tripping.Check for loose connections. Monitor appliances for intermittent faults. Consider if the circuit is overloaded. Consult a qualified electrician for further diagnosis.

7. Specifikationer

Technical specifications for the Schneider Electric Acti9 iDD40T RCBO (Model A9DA2616):

FeatureDetalje
ModelnummerA9DA2616
TypeResidual Current Circuit Breaker with Overcurrent Protection (RCBO)
polakker1P+N (1 Pole + Neutral)
Nominel strøm (ind)16 A
TrippingskurveC
Nominel restdriftsstrøm (IΔn)30 mA
Residual Current TypeAC type
Rated Short-Circuit Breaking Capacity (Icn)4500A/6kA (according to IEC 601009-2-1 and IEC 60947-2)
Nominel voltage (Ue)230-240 V AC, 50 Hz
MonteringstypeDIN-skinne
Bredde8 steps of 9mm (72mm total width)
Dimensioner (L x B x H)7.3 x 3.6 x 8.5 cm
Vægt210 gram
StandarderIEC 601009-2-1, IEC 60947-2

8. Garanti og support

For garantioplysninger og teknisk support henvises til den officielle Schneider Electric-forhandler. website or contact your local Schneider Electric representative. Keep your purchase receipt as proof of purchase.

Online ressourcer: www.se.com

Relaterede dokumenter - A9DA2616

Preview Easy9 RCBO EZ9D168 installations- og testvejledning
Installations-, tilslutnings- og testvejledning til Schneider Electric Easy9 RCBO EZ9D168 elektrisk enhed. Indeholder sikkerhedsadvarsler og tekniske specifikationer.
Preview Schneider Electric RESI9 RCBO instruktioner til udtjent levetid og bortskaffelsesvejledning
Omfattende vejledning til bortskaffelse og behandling af Schneider Electric RESI9 fejlstrømsafbrydere med overstrømsbeskyttelse (RCBO'er) efter endt levetid, inklusive demonteringsrisici og komponentinformation.
Preview Schneider Electric NF hovedafbryder interiør - 600Y/347 Vac Max paneler
Detaljerede specifikationer for Schneider Electric NF hovedafbryderens indvendige dele, designet til 600Y/347 Vac Max tavler. Dette datablad dækker NEMA 1 og vand-/smudsafvisende kabinetter, inklusive varenumre, klassificeringer og dimensioner til I-Line tavleanvendelser.
Preview Guide Utilisateur Disjoncteur Schneider A9P34706 iDT40N | 6A, 3P+N, Courbe D
Guide utilisateur detail du divisioncteur modulaire Schneider Electric A9P34706 iDT40N. Specifikationer teknikker, installation, applikationer, entretien og garanti.
Preview Installationsvejledning til Schneider Electric PowerPacT™ L-ramme afbrydersæt til NQ-paneler
Denne instruktionsbulletin fra Schneider Electric indeholder detaljerede trin til installation af NQMB6PPL-sættet, inklusive PowerPacT™ L-Frame hoved- og underafbrydere, på NQ-tavler. Indeholder sættets indhold, værktøj og sikkerhedsforanstaltninger.
Preview Installationsvejledning til monteringsplade fra Schneider Electric A9A27003
Detaljerede instruktioner til installation af Schneider Electric A9A27003 monteringspladetilbehøret til afbrydere. Indeholder trin til DIN-skinnemontering, samling og overflademontering med momentværdier og dimensioner. Overholder installationsforskrifterne.