Clore Automotive PL4050

Clore Automotive PL4050 Pro-Logix 4-Bank Battery Maintenance Station User Manual

Model: PL4050 | Mærke: Clore Automotive

1. Introduktion

The Clore Automotive PL4050 Pro-Logix 4-Bank Battery Maintenance Station is a fully automatic, multi-phase smart charger designed for 6V and 12V lead-acid batteries, including standard, AGM, and deep cycle types. This unit features four independent charging channels, each providing up to 5 amps, i alt 20 amps. It offers advanced battery maintenance capabilities, including temperature compensation and recovery modes, to ensure optimal battery health and longevity.

2. Vigtige sikkerhedsoplysninger

Læs alle instruktioner, før du bruger dette produkt. Manglende overholdelse af disse instruktioner kan resultere i elektrisk stød, brand eller alvorlig personskade.

3. Pakkens indhold

Bekræft at alle varer er til stede i pakken:

4. Produktfunktioner

The PL4050 offers a range of features for effective battery charging and maintenance:

5. Opsætning

Follow these steps to set up your PL4050 Battery Maintenance Station:

  1. Placering: Place the charger on a stable, non-combustible surface in a well-ventilated area. Ensure the charger is not exposed to direct sunlight or excessive heat.
  2. Tilslut til batteri: For each battery you wish to charge, connect the red positive (+) clamp til den positive batteripol og den sorte negative (-) polamp til batteriets negative pol. Sørg for en sikker forbindelse.
  3. Tilslut til strøm: Plug the charger's AC power cord into a standard 120V AC electrical outlet. The unit will power on.
  4. Vælg batteritype: For each connected bank, use the 'TYPE' button to select the appropriate battery type (STD for standard lead-acid, AGM for Absorbed Glass Mat). Use the 'VOLTS' button to select 6V or 12V as needed for the specific battery.
Clore Automotive PL4050 Pro-Logix 4-Bank Battery Maintenance Station

Billede 1: Forside view of the Clore Automotive PL4050 Pro-Logix 4-Bank Battery Maintenance Station, showing the four independent charging banks with controls for Start/Stop, STD/AGM, and 6V/12V selection.

6. Betjeningsvejledning

The PL4050 operates automatically once configured. Each bank functions independently.

  1. Initierende opkrævning: After connecting the battery and selecting the correct type and voltage, press the 'START/STOP' button for the desired bank. The charger will begin its multi-phase charging process. Indicators on the unit will show the charging status.
  2. Multi-Phase Charging: The charger automatically progresses through various stages, including desulfation, bulk charge, absorption, and maintenance, to optimize battery performance and lifespan.
  3. Vedligeholdelsestilstand: Once a battery is fully charged, the unit automatically switches to a maintenance (float) mode, providing a small current to keep the battery at optimal charge without overcharging. This is ideal for long-term storage.
  4. Temperaturkompensation: The PL4050 features built-in temperature compensation, which automatically adjusts the charging voltage based on ambient temperature. This ensures efficient charging in both hot and cold environments.
Temperature Compensation Feature

Image 2: Illustrates the temperature compensation feature, showing the charger automatically adjusting for temperatures ranging from -22°F to 113°F.

  1. Force Charge for Deeply Discharged Batteries: The PL4050 can initiate charging on batteries that are deeply discharged, even down to 0.0 volts. If a battery is extremely low, the charger will attempt to recover it before entering the standard charging cycle.
Force Charge Dead Batteries

Image 3: Depicts the charger's ability to force charge deeply discharged batteries, even those at 0.0 volts.

  1. Recovery Mode After Power Outages: In the event of a power interruption, the charger is designed to resume its charging process automatically once power is restored, ensuring continuous battery maintenance.
Recovery Mode for Power Outages

Image 4: Shows the recovery mode feature, indicating the charger's ability to resume operation after a power outage.

  1. Stopping Charge: To stop charging a battery, press the 'START/STOP' button for that specific bank. Disconnect the AC power cord from the outlet first, then disconnect the battery clamps.

7. Vedligeholdelse

Proper maintenance ensures the longevity and reliable operation of your PL4050 unit:

8. Fejlfinding

If you encounter issues with your PL4050, refer to the following common problems and solutions:

ProblemMulig årsagLøsning
Opladeren tænder ikke.Ingen vekselstrøm; defekt stikkontakt.Kontroller strømtilslutningen. Test stikkontakten med en anden enhed.
Opladning starter ikke.Forkert batteritilslutning; batterivolumentage too low for initial detection; incorrect battery type/voltage valgt.Sørg for, at clamps are correctly connected (positive to positive, negative to negative). Verify battery type (STD/AGM) and voltage (6V/12V) selection. For extremely low batteries, the charger may take longer to initiate or require a brief jump start from another battery to raise voltage for detection.
Charger stops unexpectedly.Overheating; internal fault; power interruption.Ensure adequate ventilation. Disconnect and reconnect. If problem persists, contact support.
One bank not working.Faulty connection; internal bank issue.Check connections for that specific bank. Try with a different battery. If issue persists, contact support.

9. Specifikationer

10. Garanti og support

Clore Automotive products are designed for reliability and performance. For specific warranty details, please refer to the documentation included with your purchase or visit the official Clore Automotive website. If you require technical assistance or have questions regarding your PL4050, please contact Clore Automotive customer support through their official channels.

Clore Automotive Webwebsted: www.cloreautomotive.com

Relaterede dokumenter - PL4050

Preview Clore Automotive Model 1002 1.5 Amp Brugermanual til 12 volt automatisk batterioplader
Denne brugermanual indeholder vigtige sikkerheds-, drifts-, vedligeholdelses- og opbevaringsinstruktioner for Clore Automotive Model 1002 1.5 Amp 12 Volt automatisk batterioplader. Lær, hvordan du oplader dit køretøjs batteri sikkert og effektivt.
Preview PRO-LOGIX PL2140 6/12V 4.0A Battery Charger/Maintainer - Product Overview
Detaljeret overview of the PRO-LOGIX PL2140, a 6/12 Volt, 4.0 Amp automatic battery charger and maintainer. Features multi-phase charging, smart clamp technology, recovery mode, and compatibility with various battery types for optimal battery care.
Preview Clore Automotive Jump-N-Carry JNCAIR 1700 & JNC660 Jump Starter brugermanual
Omfattende brugermanual til Clore Automotive Jump-N-Carry JNCAIR 1700 Peak Amp Jumpstarter med luftkompressor og JNC660 1700 Peak Amp 12 volt jumpstarter. Indeholder sikkerhedsretningslinjer, betjeningsvejledning, genopladningsprocedurer, batteriudskiftning, fejlfinding og garantioplysninger for disse bærbare strømkilder.
Preview Clore Automotive JNC325 12V Jumpstarter og strømforsyning Brugermanual
Omfattende brugermanual til Clore Automotive JNC325 12V jumpstarter og strømforsyning. Dækker sikkerhed, betjening, vedligeholdelse, specifikationer, fejlfinding og garantioplysninger.
Preview Sikkerhedsdatablad (SDS) for genopladelige batterier til Clore Automotive VRLA - JNC Jumpstartere
Omfattende sikkerhedsdatablad (SDS) for Clore Automotive VRLA genopladelige batterier og JNC bærbare jumpstartere, med detaljerede oplysninger om farer, håndtering, førstehjælp og bortskaffelse.
Preview PRO-LOGIX PL2140: 6/12V 4.0A intelligent batterioplader og vedligeholdelsesenhed
Oplev PRO-LOGIX PL2140 fra Clore Automotive, en alsidig 6/12V 4.0A intelligent batterioplader og -vedligeholder. Med avanceret flerfaset opladning, LiFePO4-kompatibilitet, gendannelsestilstand og batterireparationsfunktioner for optimal batteripleje.