1. Introduktion
Thank you for choosing the Nilox UPS Premium Line Interactive 1200 VA. This Uninterruptible Power Supply (UPS) is designed to protect your electronic devices from power outages, bindtage fluctuations, and electrical disturbances, ensuring stable power delivery and allowing for safe shutdown during extended blackouts. This manual provides essential information for the safe and efficient operation of your UPS.
2. Sikkerhedsoplysninger
Please read all safety instructions carefully before installation and operation. Failure to follow these instructions may result in damage to the unit, connected equipment, or personal injury.
- Åbn ikke UPS'en casing. Der er ingen dele indeni, som brugeren kan servicere. Overlad al service til kvalificeret servicepersonale.
- Tilslut ikke apparater, der kan overbelaste UPS'en, såsom laserprintere, støvsugere eller varmeapparater.
- Sørg for, at UPS'en er tilsluttet en jordet stikkontakt.
- Do not expose the UPS to water, excessive humidity, or extreme temperatures. Operate in a well-ventilated area.
- In case of fire, use a dry chemical fire extinguisher. Water may cause electrical shock.
- The internal battery is not user-replaceable. Battery replacement should only be performed by qualified service personnel.
3. Produktet er slutview
Familiarize yourself with the components of your Nilox UPS.

Figur 3.1: Forside View. This image displays the front panel of the UPS, featuring the power button and LED indicators for operational status.

Figur 3.2: Bagside View. This image shows the back of the UPS, highlighting the two output sockets for connecting devices and the USB port for PC/Server connection.

Figur 3.3: Samlet produkt ViewEn omfattende view of the UPS, illustrating its compact tower form factor suitable for various environments.
Indikatorer på frontpanelet:
- Power knap: Bruges til at tænde eller slukke UPS'en.
- LED-indikatorer: Display the operational status, such as AC mode, battery mode, fault, or low battery. Consult the specific LED pattern in the troubleshooting section for detailed meanings.
Tilslutninger bagpanel:
- Udgangsstik: Two sockets providing battery backup and surge protection for connected devices.
- USB-port: For connecting the UPS to a computer or server to enable monitoring and automatic shutdown software.
- Input strømledning: Connects the UPS to the main AC power supply.
4. Opsætning
Follow these steps to set up your UPS for the first time:
- Udpakning: Tag forsigtigt UPS'en ud af emballagen. Undersøg den for eventuelle forsendelsesskader.
- Placering: Place the UPS in a cool, dry, and well-ventilated indoor environment, away from direct sunlight, heat sources, and excessive dust. Ensure adequate clearance around the unit for proper airflow.
- Indledende opladning: Before connecting any devices, plug the UPS into a standard wall outlet and allow it to charge for at least 8 hours. This ensures the internal battery is fully charged and ready to provide optimal backup time.
- Tilslutning af enheder: After the initial charge, connect your computer, monitor, and other critical peripherals to the output sockets on the rear of the UPS. Ensure the total power consumption of connected devices does not exceed the UPS's capacity (840 Watts / 1200 VA).
- Softwareinstallation (valgfrit): For advanced monitoring and automatic shutdown features, connect the USB cable from the UPS to your computer. Install the UPS management software, which is compatible with Windows, Mac OS X (up to version 10.8), Unix, and Linux. Refer to the software's documentation for installation and usage instructions.
5. Betjeningsvejledning
Tænd/sluk for UPS'en:
- At tænde: Press and hold the power button on the front panel for approximately 3 seconds until you hear a beep and the LED indicators illuminate.
- At slukke: Press and hold the power button for approximately 3 seconds until you hear a beep and the LED indicators turn off.
Understanding Operational Modes:
- AC-tilstand: When the UPS is connected to a stable AC power source, it operates in AC mode, providing filtered power to connected devices and charging the battery.
- Batteritilstand: Under en magt outage eller betydelig volumentage fluctuation, the UPS automatically switches to battery mode, providing power from its internal battery. An audible alarm will sound, and the corresponding LED indicator will light up.
- Automatisk voltage Forordning (AVR): The built-in AVR system automatically corrects minor voltage fluctuations (sags or surges) without switching to battery power, thus prolonging battery life.
6. Vedligeholdelse
Korrekt vedligeholdelse sikrer din UPS' levetid og optimal ydeevne.
- Batteripleje: To maximize battery life, ensure the UPS is always connected to an AC outlet to keep the battery charged. If the UPS is stored for an extended period, recharge it every three months to prevent battery discharge.
- Rensning: Brug en tør, blød klud til at rengøre UPS'ens yderside. Brug ikke flydende rengøringsmidler eller rengøringsmidler på aerosol.
- Ventilation: Kontrollér regelmæssigt, at ventilationsåbningerne er fri for støv og snavs for at forhindre overophedning.
- Udskiftning af batteri: The internal lead-acid battery has a limited lifespan. If the UPS's backup time significantly decreases, the battery may need replacement. Contact qualified service personnel for battery replacement.
7. Fejlfinding
Hvis du støder på problemer med din UPS, kan du se følgende almindelige problemer og løsninger:
| Problem | Mulig årsag | Løsning |
|---|---|---|
| UPS'en tænder ikke. | No AC input; Low battery; Power button not pressed long enough. | Ensure UPS is plugged into a live outlet. Allow battery to charge for 8 hours. Press and hold power button for 3 seconds. |
| UPS'en bipper kontinuerligt i AC-tilstand. | Overbelastning; Intern fejl. | Reduce connected load. If problem persists, contact support. |
| UPS'en skifter ofte til batteritilstand. | Unstable AC power; High sensitivity setting. | Check building wiring. If using software, adjust sensitivity settings. |
| Kort backuptid. | Batteriet er ikke fuldt opladet; Batteriet er ved at være slut; Overbelastning. | Allow battery to fully charge. Reduce connected load. Consider battery replacement if old. |
| USB communication not working. | Incorrect cable; Driver issue; Software not installed. | Ensure correct USB cable is used. Reinstall UPS management software and drivers. |
If the problem persists after trying these solutions, please contact Nilox customer support.
8. Specifikationer
Key technical specifications for the Nilox UPS Premium Line Interactive 1200 VA:
| Feature | Specifikation |
|---|---|
| Modelnummer | NXGCLI12001X7V2 |
| Kapacitet | 1200 VA / 840 Watt |
| Input bindtage | 233 volt (nominel) |
| Udgangsstik | 2 (Battery Backup & Surge Protected) |
| Batteritype | Forseglet blysyre |
| Typisk genopladningstid | 8 Hours to 90% capacity |
| Typisk backuptid (fuld belastning) | 7 minutter |
| Dimensioner (L x B x H) | 32 x 22 x 14 cm |
| Vægt | 3.6 kg |
| Formfaktor | Tårn |
| Forbindelse | USB |
9. Garanti og support
Garantioplysninger:
The Nilox UPS Premium Line Interactive 1200 VA comes with a 3 års garanti på stedet on electronic parts. This warranty covers defects in materials and workmanship under normal use. Please retain your proof of purchase for warranty claims.
Kundesupport:
For technical assistance, troubleshooting beyond this manual, or warranty service, please contact Nilox customer support. Refer to the official Nilox webwebstedet eller din produktemballage for at få de mest aktuelle kontaktoplysninger.
When contacting support, please have your product model number (NXGCLI12001X7V2) and purchase date ready.