Everbilt HPEBAU33

Everbilt 1/3 HK automatisk forsyningspumpe HPEBAU33 brugsanvisning

1. Produktet er slutview

The Everbilt 1/3 HP Automatic Utility Pump HPEBAU33 is designed for efficient water removal from various low-lying areas such as crawl spaces and window wells. This submersible pump features an integrated mini-float switch for automatic operation, activating when water levels reach approximately 1-1/2 inches and deactivating when levels drop to about 1/8 inch. It is important to note that this pump is not intended for permanent installation, nor should it be used as a sump pump or in sewage/septic systems.

Everbilt 1/3 HP Automatic Utility Pump HPEBAU33

Figur 1: Everbilt 1/3 HP Automatic Utility Pump HPEBAU33. This image displays the pump's compact design, including the power cord connection and the threaded discharge outlet.

2. Sikkerhedsoplysninger

Read and understand all safety instructions before operating the pump. Failure to follow these instructions may result in electric shock, fire, serious injury, or death.

3. Pakkens indhold

Kontroller, at alle genstande er til stede og ubeskadigede ved udpakning:

4. Specifikationer

FeatureSpecifikation
ModelnummerHPEBAU33
Hestekræfter1/3 HK (0.33 HK)
StrømtypeAC elektrisk
Voltage115V
Ampslette3 A
Maximum Discharge Flow (0 ft. head)1620 Gallons per Hour (27 GPM)
Maximum Discharge Flow (10 ft. head)1260 Gallons per Hour (21 GPM)
Maksimal udløbshøjde28 fod.
PumpeafbrydertypeFloat Switch (Automatic)
Turn-On Water LevelApproximately 1-1/2 in.
Turn-Off Water LevelApproximately 1/8 in.
Udløbsudtag1-1/4 in. MIP (Male Iron Pipe)
Ledningslængde10 fod.
Materiale til husTermoplastisk
Maksimal arbejdstemperatur95°F (35°C)
Minimum arbejdstemperatur33°F (0.5°C)
Produktmål (L x B x H)12 cm x 8 cm x 6 cm
Varens vægt8.8 lbs

5. Opsætningsvejledning

  1. Placering: Position the pump on a stable, level surface in the area where water removal is needed. Ensure the pump's intake screen is clear of debris. The pump is suitable for crawl spaces, window wells, and other low-lying areas.
  2. Afladningsforbindelse:
    • For standard garden hoses: Attach the provided 3/4 inch garden hose adapter to the pump's 1-1/4 inch MIP discharge outlet. Then, connect a standard garden hose to the adapter.
    • For larger discharge hoses: Connect a 1-1/4 inch discharge hose directly to the pump's 1-1/4 inch MIP discharge outlet. The included 1-1/4 inch check valve should be installed in the discharge line to prevent backflow.
    Ensure all connections are secure to prevent leaks. Route the discharge hose to a suitable drainage area, away from the pump's location, to prevent water recirculation.
  3. Strømtilslutning: Plug the 10 ft. power cord into a grounded 115V AC electrical outlet. Ensure the outlet is protected by a Ground Fault Circuit Interrupter (GFCI) for added safety, especially in wet environments.
  4. Indledende kontrol: Before operation, ensure the pump is fully submerged in water or will be submerged once water levels rise. The float switch requires water to operate correctly.

Vigtig bemærkning: This pump is not designed for permanent installation and should not be used as a primary sump pump for continuous, long-term operation in a sump pit. It is intended for temporary water removal applications.

6. Betjeningsvejledning

The Everbilt HPEBAU33 pump operates automatically based on water levels detected by its integrated mini-float switch.

  1. Automatisk drift: Once plugged in and placed in water, the pump will automatically turn on when the water level reaches approximately 1-1/2 inches. It will continue to pump water until the level drops to approximately 1/8 inch, at which point the pump will automatically turn off.
  2. Continuous Readiness: The pump can be left plugged in indefinitely, allowing it to activate automatically whenever water accumulates to the turn-on level.
  3. Overvågning: Periodically check the pump's operation and the discharge area to ensure proper function and prevent blockages.

7. Vedligeholdelse

Regelmæssig vedligeholdelse sikrer optimal ydeevne og forlænger pumpens levetid.

8. Fejlfinding

Hvis du støder på problemer med din pumpe, kan du se følgende almindelige problemer og løsninger:

ProblemMulig årsagLøsning
Pumpen tænder ikke.No power; float switch obstructed; water level too low; clogged intake.Check power connection and GFCI. Ensure float switch moves freely. Verify water level is above 1-1/2 inches. Clean intake screen.
Pumpen kører, men der kommer ikke vand ud, eller flowet er lavt.Discharge hose kinked or blocked; pump not fully submerged; air lock; clogged intake.Check and clear discharge hose. Ensure pump is fully submerged. Briefly lift and lower pump to release air. Clean intake screen.
Pumpen slukker ikke.Float switch obstructed or stuck in "on" position; debris preventing water from draining below turn-off level.Unplug pump and check float switch for obstructions. Ensure area around pump is clear for water to drain.
Pump makes unusual noise.Debris in impeller; pump running dry.Disconnect power, inspect and clear impeller. Ensure pump is always submerged during operation.

9. Garanti og support

This Everbilt pump is covered by a 1 års producentgaranti fra købsdatoen. Denne garanti dækker fejl i materialer og udførelse ved normal brug.

For warranty claims, technical assistance, or replacement parts, please contact Everbilt customer support. Keep your purchase receipt as proof of purchase.

Please refer to the official Everbilt website or your product packaging for the most current contact information and detailed warranty terms.

Relaterede dokumenter - HPEBAU33

Preview Everbilt 1/3 HP Submersible Automatic Utility Pump Use and Care Guide
Comprehensive use and care guide for the Everbilt 1/3 HP Submersible Automatic Utility Pump (Model EBAU33). Covers performance, safety, installation, operation, maintenance, and troubleshooting.
Preview Everbilt 2-in-1 Utility Pump Quick Start Guide
A quick start guide for the Everbilt 2-in-1 Utility Pump (Model UTA02510), providing instructions for setup, operation, and safety in both English and Spanish.
Preview Everbilt 1/4 HK nedsænkbar pooloverdækningspumpe: Brugs- og vedligeholdelsesvejledning
Omfattende guide til Everbilt 1/4 HP dykpumpe til poolovertræk, der dækker installation, betjening, vedligeholdelse, sikkerhed og fejlfinding. Lær, hvordan du effektivt bruger og vedligeholder din Everbilt poolpumpe.
Preview Everbilt dykpumpe til forsyningsbrug – hurtig referencevejledning
En hurtig referencevejledning til Everbilt dykpumpen, der indeholder vigtige installations- og betjeningsinstruktioner. Lær, hvordan du tilslutter slangen, placerer pumpen, primer den og tilslutter den til strøm.
Preview Brugs- og vedligeholdelsesvejledning til Everbilt dykpumpe | SP03302EP, SP05002VD
This comprehensive guide provides essential information for the safe and effective use, care, and maintenance of Everbilt submersible sump pumps, models SP03302EP and SP05002VD. Learn about performance specifications, assembly, operation, troubleshooting, and warranty details.
Preview Everbilt dykpumpe til vandfald/forsyningspumpe – hurtig referencevejledning
En hurtig referencevejledning til installation og betjening af Everbilt dykpumpe til vandfald/forsyningsanlæg, inklusive tips til opsætning, priming og fejlfinding.