The Maxspect Jump Gyre MJ-GF2K is an advanced crossflow circulation pump designed for aquariums, providing efficient and near-silent water movement. Utilizing the same sinusoidal wave technology found in the high-end Gyre 300 series, this pump ensures optimal water flow for a healthy aquatic environment. The MJ-GF2K model is rated at 7500 liters per hour (approximately 1980 GPH) and is suitable for aquariums ranging from 50 to 250 liters (approximately 13 to 66 gallons). It includes a flow director plug, making it adaptable for smaller nano systems.

The pump comes with two sets of rotors: one elegant orange set and an additional black set for those preferring a more subdued aesthetic. It is supplied as a single-pump controller set, with the controller capable of running programmable 24-hour cycles across multiple flow modes.

Maxspect Jump Gyre MJ-GF2K Crossflow Circulation Pump

Figur 1: The Maxspect Jump Gyre MJ-GF2K Crossflow Circulation Pump, showcasing its dual rotor design and protective grilles.

Nøglefunktioner:

2. Sikkerhedsinstruktioner

Please read and understand all safety instructions before operating the Maxspect Jump Gyre MJ-GF2K pump. Failure to follow these instructions may result in injury or damage to the product or aquarium.

3. Pakkens indhold

Carefully unpack all items and check for any damage. If any components are missing or damaged, please contact your retailer or Maxspect customer support immediately.

Maxspect Jump Gyre MJ-GF2K Package Contents

Figur 2: All components included in the Maxspect Jump Gyre MJ-GF2K package: pump, controller, power supply, and accessories.

4. Opsætning og installation

Follow these steps to properly install your Maxspect Jump Gyre MJ-GF2K pump in your aquarium.

  1. Vælg placering: Select a location in your aquarium that allows for optimal water circulation. Crossflow pumps are typically placed horizontally near the water surface, on the side or back wall. Ensure the pump is fully submerged when operating.
  2. Prepare Magnetic Mount: The pump uses a magnetic mount. Place the inner magnetic bracket onto the pump unit. Position the pump inside the aquarium at your desired location.
  3. Secure External Magnet: Align the external magnetic bracket on the outside of the aquarium glass, directly opposite the internal magnet. The strong magnets will hold the pump securely in place. The maximum glass thickness supported is 15mm.
  4. Tilslut til controller: Connect the pump's cable to the designated port on the controller unit. Ensure the connection is secure.
  5. Tilslut strømforsyning: Connect the power supply adapter to the controller unit, then plug the power cord into the power supply.
  6. Sæt i stikkontakten: Plug the power cord into a GFCI-protected electrical outlet. Ensure a drip loop is formed with the power cord to prevent water from reaching the outlet.
  7. Optional Flow Director Plug: If using the pump in a smaller nano system or to direct flow more precisely, insert the provided flow director plug into one end of the pump's rotor housing. This will restrict flow from that side, concentrating it to the other.
Maxspect Jump Gyre MJ-GF2K Pump and Controller Setup

Figur 3: The Maxspect Jump Gyre MJ-GF2K pump connected to its controller, ready for installation in an aquarium.

5. Betjeningsvejledning

The Maxspect Jump Gyre MJ-GF2K controller allows for various flow modes and programmable cycles to suit your aquarium's needs.

Controller overview:

The controller features a display screen and several buttons for navigation and setting adjustments. Refer to the controller's specific button layout for detailed operation.

Flowtilstande:

The controller offers multiple flow modes to simulate natural reef environments:

Programming 24-Hour Cycles:

The controller allows you to set up a 24-hour schedule, switching between different flow modes and intensities throughout the day. Consult the controller's specific instructions for detailed programming steps. This typically involves:

  1. Går ind i programmeringstilstand.
  2. Setting start and end times for each program segment.
  3. Selecting the desired flow mode and intensity for each segment.
  4. Gemmer programmet.

Note: This pump cannot be used in a 2-pump, 1-controller version and is not compatible with the SYNA G application.

6. Vedligeholdelse

Regular maintenance is crucial for the longevity and optimal performance of your Maxspect Jump Gyre pump. Always disconnect power before performing any maintenance.

Routine Cleaning (Monthly):

  1. Afbryd strømmen: Unplug the pump from the power outlet.
  2. Fjern fra akvariet: Carefully remove the pump unit from the aquarium.
  3. Skille ad: Gently twist and pull apart the pump housing to access the rotors and impellers. Note the orientation of all parts for reassembly.
  4. Rengøring af komponenter: Use a soft brush (like a toothbrush) and warm water to remove any algae, detritus, or calcium buildup from the rotors, impellers, and pump housing. For stubborn calcium deposits, a mild vinegar solution can be used. Rinse thoroughly with fresh water.
  5. Undersøg dele: Check the rotors, impellers, and shafts for any signs of wear, cracks, or damage. Replace any worn parts.
  6. Saml igen: Carefully reassemble the pump, ensuring all parts fit snugly and are correctly oriented.
  7. Geninstaller: Reinstall the pump in the aquarium and reconnect power.

Rotor udskiftning:

The pump comes with an additional set of black rotors. You can replace the orange rotors with the black ones, or replace worn rotors as needed. Follow the disassembly and reassembly steps from the "Routine Cleaning" section to swap out the rotors.

7. Fejlfinding

If you encounter issues with your Maxspect Jump Gyre pump, refer to the following troubleshooting guide. If the problem persists, contact Maxspect customer support.

ProblemMulig årsagLøsning
Pumpen tænder ikke.Ingen strøm til enheden.
Løs forbindelse.
Controllerfejl.
Check if the power cord is securely plugged into the outlet and the controller. Ensure the outlet has power (test with another device). Verify all connections between pump, controller, and power supply.
Pump running but with reduced flow.Algae or debris buildup on rotors/impellers.
Worn rotors/impellers.
Incorrect mode setting.
Disconnect power and clean the pump thoroughly as per maintenance instructions. Inspect rotors and impellers for wear and replace if necessary. Check the controller settings to ensure the desired flow intensity is selected.
Pumpen laver usædvanlig lyd.Debris lodged in pump.
Worn rotors/impellers or shaft.
Improper assembly after cleaning.
Disconnect power and inspect the pump for any foreign objects. Clean the pump thoroughly. Check for worn parts and replace if needed. Ensure all components are correctly reassembled.
Controller display is blank or unresponsive.Strøm problem.
Controllerfejl.
Ensure the power supply is connected and receiving power. Try unplugging and replugging the power supply. If the issue persists, the controller may be faulty.

8. Specifikationer

Technical specifications for the Maxspect Jump Gyre MJ-GF2K Crossflow Circulation Pump.

SpecifikationVærdi
ModelnummerMJ-GF2K (Internal Ref: 2036)
MærkeMaxspect
Strømforbrug25 watt
Voltage220 volt (AC)
Frekvens50 Hz
Max flowhastighed7000 L/H (approx. 1850 GPH) / 116.67 Liters per minute
Anbefalet akvariestørrelse50 - 250 Liters (approx. 13 - 66 Gallons)
Max Glass Thickness15 mm
Dimensioner (L x B x H)22.3 x 7.2 x 3.81 cm (8.78 x 2.83 x 1.5 tommer)
Vægt457 gram (ca. 1.01 lbs)
MaterialePlast
FarveOrange, Sort
StrømkildeElektrisk med ledning

9. Garanti og support

Maxspect products are manufactured to high-quality standards. Specific warranty terms and conditions may vary by region and retailer. Please retain your proof of purchase for any warranty claims.

Information regarding spare parts availability is currently unavailable through this product listing. For technical support, warranty inquiries, or to purchase replacement parts, please contact your authorized Maxspect retailer or visit the official Maxspect webwebsted for kontaktoplysninger.

Fabrikant: Maxspect

Relaterede dokumenter - MJ-GF2K

Preview Maxspect Gyre 300-serien Cloud Edition Gyre Flow Pumpe brugermanual
Omfattende brugermanual til Maxspect Gyre 300-serien Cloud Edition Gyre Flow-pumpe, med detaljerede oplysninger om installation, betjening, vedligeholdelse, sikkerhedsforanstaltninger og garanti.
Preview Maxspect Dice Series Pico Cube Smart Aquarium Brugermanual - Opsætning, betjening, vedligeholdelse
Omfattende brugermanual til Maxspect Dice Series Pico Cube Smart Aquarium. Lær om opsætning, sikkerhedsforanstaltninger, komponentidentifikation, betjeningsinstruktioner, vedligeholdelsesprocedurer og garantioplysninger. Forestil dig livet levende med Maxspect.
Preview Maxspect Jump Series Proteinskimmer Brugermanual
En omfattende guide til Maxspect Jump Series proteinskimmeren, der beskriver opsætning, betjening, vedligeholdelse, sikkerhedsforanstaltninger og reservedele til akvarieentusiaster.
Preview Maxspect Jump Series Proteinskimmer Brugermanual
Omfattende brugermanual til Maxspect Jump Series Protein Skimmer, der dækker opsætning, betjening, vedligeholdelse og garanti. Funktionerne omfatter dobbelte vandindtag, dobbelte nålehjul og en overløbssensor.
Preview Maxspect Jump Series MJ-L165 LED-belysningssystem brugermanual
Omfattende brugermanual til Maxspect Jump Series MJ-L165 LED-belysningssystem, der dækker installation, betjening, sikkerhedsforanstaltninger og vedligeholdelse.
Preview Maxspect Gyre 300CE-serien Cloud Edition: Næsten lydløs drift, sikkerheds- og garantivejledning
En omfattende brugermanual til Maxspect Gyre 300CE Series Cloud Edition flowpumpen, der beskriver dens næsten lydløse drift, sinusbølgeteknologi, pakkens indhold, installation, betjening, vedligeholdelse, sikkerhedsforanstaltninger og begrænsede garanti.