1. Introduktion
This manual provides essential information for the safe and efficient operation of your Schneider Conext System Control Panel (SCP) model 865-1050-01. Please read this manual thoroughly before installation and operation to ensure proper use and to prevent damage to the unit or connected equipment.
2. Sikkerhedsoplysninger
Overhold altid følgende sikkerhedsforanstaltninger for at mindske risikoen for elektrisk stød, brand eller personskade:
- Installation skal udføres af kvalificeret personale.
- Sørg for, at alle strømkilder er afbrudt før installation eller vedligeholdelse.
- Do not operate the SCP if it has been damaged in any way.
- Hold enheden væk fra vand, fugt og brandfarlige materialer.
- Refer to the main system inverter/charger manual for comprehensive safety guidelines.
3. Produktet er slutview
The Conext System Control Panel (SCP) provides a comprehensive display and control interface for Conext inverter/charger systems. It allows for monitoring system status, configuring settings, and managing power flow.
3.1. komponenter
- LCD-skærm: Shows system status, parameters, and menu options.
- Navigationsknapper: "Enter", "Up", "Down", and "Exit" for menu navigation and setting adjustments.
- Event/Warning LED: Illuminates to indicate system events or warnings.
- Standby LED: Indicates the system's standby status.

Figur 1: Forside view of the Schneider Conext System Control Panel (SCP) 865-1050-01. The panel features an LCD screen displaying system information such as mode, battery voltage, and AC output. Below the screen are four control buttons: Enter, Up arrow, Down arrow, and Exit. To the left of the screen is an 'Event/Warning' indicator, and to the right is a 'Standby' indicator. The Schneider Electric logo is visible in the bottom right corner.
4. Opsætning og installation
The SCP is designed for easy integration with Conext inverter/charger systems. Follow these steps for proper installation:
- Montering: Choose a suitable location for mounting the SCP, ensuring it is easily accessible and protected from direct sunlight or extreme temperatures. Use appropriate fasteners to secure the panel to a wall or surface.
- Kabelføring: Connect the SCP to the Conext inverter/charger using the provided communication cable. Ensure the cable is securely connected to the designated ports on both the SCP and the inverter/charger.
- Tænd: Once all connections are secure, power on the Conext system. The SCP display should illuminate and begin showing system status.
- Indledende konfiguration: Refer to the Conext inverter/charger manual for initial system configuration and network setup, if applicable. The SCP will reflect these settings.
Note: Always ensure the system is powered off before making any physical connections or disconnections.
5. Operating the System Control Panel
The SCP provides intuitive navigation for monitoring and controlling your Conext system.
5.1. Grundlæggende navigation
- Viewing Status: The main screen displays real-time system parameters such as battery voltage, AC output, and operating mode. Use the Up/Down arrows to scroll through different status screens.
- Adgang til menuer: Press the "Enter" button to access the main menu.
- Navigering i menuer: Use the Up/Down arrows to scroll through menu options. Press "Enter" to select an option.
- Afslutning af menuer: Press the "Exit" button to go back to the previous screen or to the main status display.
5.2. Fælles operationer
- Ændring af indstillinger: Navigate to the desired setting within the menu, press "Enter", use Up/Down to adjust the value, and press "Enter" again to confirm.
- Viewing Event Logs: The SCP stores a log of system events and warnings. Access this from the main menu to review historiske data.
- System On/Off: Depending on your system configuration, the SCP may allow you to initiate system shutdown or startup. Refer to your inverter/charger manual for specific procedures.
6. Vedligeholdelse
The Conext SCP requires minimal maintenance to ensure long-term reliable operation.
- Rensning: Tør displayet og c af med jævne mellemrum.asinmed en blød, tør klud. Brug ikke slibende rengøringsmidler eller opløsningsmidler.
- Inspektioner: Regularly check the communication cable for any signs of damage or loose connections.
- Firmwareopdateringer: If firmware updates are available for your Conext system, they are typically applied through the inverter/charger unit. Consult the inverter/charger manual or Schneider Electric support for update procedures.
7. Fejlfinding
If you encounter issues with your SCP, refer to the following common troubleshooting steps:
| Problem | Mulig årsag | Løsning |
|---|---|---|
| SCP display is blank. | No power to the system or loose communication cable. | Ensure the Conext system is powered on. Check communication cable connections at both the SCP and the inverter/charger. |
| Forkerte aflæsninger på displayet. | System not properly calibrated or communication error. | Verify system settings through the inverter/charger. Restart the system. If issues persist, contact support. |
| Knapperne reagerer ikke. | Midlertidig softwarefejl eller fysisk skade. | Restart the Conext system. If buttons remain unresponsive, contact Schneider Electric support. |
For more complex issues, consult the comprehensive troubleshooting section in your Conext inverter/charger manual or contact Schneider Electric technical support.
8. Specifikationer
Key technical specifications for the Schneider Conext System Control Panel (SCP) 865-1050-01:
- Model: 865-1050-01
- Kompatibilitet: Conext XW+, SW, and other compatible Schneider Electric inverter/charger systems.
- Vise: Baggrundsbelyst LCD
- Interface: Intuitive button navigation
- Meddelelse: Xanbus network
- Fabrikant: Conext (as per product specifications)
- ASIN: B07XVPK5BD
- Dato først tilgængelig: 7. december 2023
9. Garanti og support
For detailed warranty information, please refer to the warranty card included with your Conext system or visit the official Schneider Electric website. Technical support is available through Schneider Electric's customer service channels. Please have your product model number (865-1050-01) and serial number ready when contacting support.
Schneider Electrics officielle Webwebsted: www.se.com