Indledning
This manual provides essential instructions for the safe and efficient operation of your Volt Polska Micro UPS 1200/720W. Please read this manual thoroughly before installation and use, and retain it for future reference. This Uninterruptible Power Supply (UPS) is designed to provide backup power and protect your electronic equipment from power outages, surges, and fluctuations.

Billede 1: Front view of the Volt Polska Micro UPS 1200/720W, showcasing its compact design and the blue LCD display panel.
Opsætning
- Udpakning: Carefully remove the UPS from its packaging. Inspect the unit for any damage that may have occurred during transit. If any damage is found, do not operate the unit and contact your dealer.
- Placering: Place the UPS in a well-ventilated area, away from direct sunlight, heat sources, and excessive moisture. Ensure there is adequate space around the unit for proper airflow.
- Indledende opladning: Before initial use, connect the UPS to a standard wall outlet and allow it to charge for at least 8-12 hours. This ensures the internal batteries are fully charged and ready to provide optimal backup time.
- Tilslutning af enheder: Plug your computer, monitor, and other critical electronic devices into the UPS output sockets. Do not connect laser printers or heaters to the UPS, as their high power consumption can overload the unit.
- USB-kommunikation (valgfrit): For advanced monitoring and shutdown features, connect the provided USB cable from the UPS to your computer's USB port. Install the appropriate software (not included, typically available from manufacturer's website) for your operating system.

Billede 2: Bag view of the UPS, illustrating the input power cord, output sockets for connected devices, the circuit breaker, and the USB communication port.

Billede 3: The USB cable used for connecting the UPS to a computer for monitoring and controlled shutdown.
Betjeningsvejledning
- Tænd/sluk: Press and hold the power button on the front panel for a few seconds to turn the UPS on or off. The LCD display will illuminate upon startup.
- LCD-skærm: The LCD display provides real-time information about the UPS status, including input voltage, output voltage, battery level, and load capacity. Refer to the display for operational insights.
- Batteritilstand: I tilfælde af en magt outage, the UPS will automatically switch to battery mode, providing power to connected devices. An audible alarm will sound, and the display will indicate battery operation.
- Overbelastningsbeskyttelse: If the connected load exceeds the UPS's capacity, an overload alarm will sound, and the UPS may shut down to prevent damage. Disconnect non-essential devices to reduce the load.
- Advarsel om lavt batteri: When the battery level is critically low, the UPS will emit a continuous alarm, signaling that connected devices should be safely shut down to prevent data loss.

Billede 4: En detaljeret view of the UPS's LCD display, showing current input and output voltage readings during operation.
Opretholdelse
- Batteripleje: The UPS uses Lead Acid, AGM batteries. To maximize battery life, avoid frequent deep discharges. Perform a full discharge/recharge cycle every 3-6 months if the UPS is not frequently used in battery mode.
- Rensning: Keep the UPS clean and free from dust. Use a dry, soft cloth to wipe the exterior. Do not use liquid or aerosol cleaners. Ensure ventilation openings are clear of obstructions.
- Opbevaring: If storing the UPS for an extended period, ensure the batteries are fully charged. Recharge the batteries every three months to prevent permanent damage due to self-discharge. Store in a cool, dry place.
Fejlfinding
| Problem | Mulig årsag | Løsning |
|---|---|---|
| UPS'en tænder ikke | No input power; Low battery | Check power cord connection; Charge UPS for 8-12 hours |
| UPS beeps continuously in normal mode | Overbelastningstilstand | Reduce connected load by unplugging non-essential devices |
| Kort backuptid | Batteries not fully charged; Old batteries | Charge UPS for 8-12 hours; Consider battery replacement if old |
| UPS does not provide power during outage | UPS not connected to AC power; UPS is off | Ensure UPS is plugged into a live outlet; Turn UPS on |
Specifikationer
| Feature | Detalje |
|---|---|
| Mærke | Volt Polska |
| Model | 5UP1200027 |
| Kapacitet | 1200VA / 720W |
| Batteritype | Lead Acid, AGM (2 x 7 Ah) |
| Dimensioner (L x B x H) | 37 x 13.5 x 16.5 cm |
| Vægt | 9.2 kilo |
| Første ledige dato | 29. august 2019 |
Garanti og support
For warranty information or technical support, please refer to the documentation provided with your purchase or contact Volt Polska directly. Ensure you have your model number (5UP1200027) and purchase details available when seeking support.