1. Introduktion

The ACR ResQLink 400 is a compact, buoyant, GPS-enabled Personal Locator Beacon (PLB) designed to provide a direct link to rescue services in an emergency. When activated, it transmits a powerful 406 MHz distress signal to the Cospas-Sarsat satellite system, along with your precise GPS location, alerting search and rescue efforts worldwide. This device is intended for use in outdoor emergencies across various activities including hiking, hunting, boating, and fishing.

ACR ResQLink 400 Personal Locator Beacon

Image: The ACR ResQLink 400 Personal Locator Beacon, a compact, bright yellow and clear device.

Person hiking with ACR ResQLink 400 attached to backpack

Image: The ResQLink 400 attached to a backpack during a hike, demonstrating portability.

2. Nøglefunktioner

3. Opsætning og registrering

Before using your ResQLink 400, it is critical to register your beacon with the appropriate national authority. In the United States, this is the National Oceanic and Atmospheric Administration (NOAA). Registration is free and mandatory. It provides search and rescue forces with vital information about you and your vessel/activity, which can significantly aid in a rescue operation.

For detailed activation instructions, please refer to the video below:

Video: ACR ResQlink 400 + 425 Activation Guide. This video demonstrates the steps to activate your Personal Locator Beacon in an emergency.

Initial Registration Steps:

  1. Visit the official beacon registration webwebsted for dit land (f.eks. NOAA for USA).
  2. Locate your beacon's Unique Identifier Number (UIN) or Hex ID, typically found on the device label.
  3. Complete the online registration form with accurate personal and emergency contact information.
  4. Keep your registration information up-to-date, especially if your contact details or emergency contacts change.

4. Operating the ResQLink 400 in an Emergency

The ResQLink 400 is designed for simple, rapid deployment in life-threatening situations. Follow these steps carefully:

  1. Deploy the Antenna: Slide the antenna cover up and extend the antenna fully. Ensure it is positioned at a 90-degree angle to the beacon and has a clear view af himlen for optimal satellitmodtagelse.
  2. Activate the Beacon: Press and hold the red "ON" button for approximately 2 seconds until the red LED light begins to flash. The device will start acquiring GPS coordinates and transmitting the distress signal.
  3. Confirm GPS Acquisition: Once GPS coordinates are acquired, the red LED will turn green, indicating a successful position fix. The strobe light will also begin to flash.
  4. Bevar stilling: Leave the beacon in an open area with an unobstructed view of the sky. Do not turn it off until rescue personnel confirm your safety.
Person holding ACR ResQLink 400 on a boat

Image: A person holding the ACR ResQLink 400 Personal Locator Beacon on a boat, demonstrating its use in a marine environment.

5. Self-Test Procedure

Regular self-testing ensures your ResQLink 400 is functioning correctly. Perform a self-test monthly or before any extended trip.

Video: ACR ResQlink 400 + 425 Self-Test Guide. This video provides instructions on how to perform a self-test on your Personal Locator Beacon.

Steps for Self-Test:

  1. Deploy Antenna: Slide the antenna cover up and extend the antenna fully.
  2. Initiate Self-Test: Press and hold the "T" (Test) button for approximately 2 seconds.
  3. Observer LED'er: The green LED will flash once, followed by a second green LED flash. If you have the "View" model, the display will confirm "SELF TEST PASS".
  4. Vigtig bemærkning: During the self-test, ensure you do not touch the antenna. Holding the antenna can interfere with the test and potentially cause it to fail.

If the self-test fails (e.g., red LED flashes, no display message, or "FAIL" message), consult the troubleshooting section or contact ACR support.

6. Vedligeholdelse og pleje

7. Fejlfinding

SpørgsmålMulig årsagLøsning
Self-Test Fails (Red LED)Antenna not deployed correctly, low battery, internal fault.Ensure antenna is fully extended and not obstructed. Check battery expiration. If issue persists, contact ACR support.
No GPS Acquisition during activationHindret view of sky, device not stationary.Gå til et åbent område med en klar view of the sky. Keep the device stationary during activation.
Enheden tænder ikkeDepleted or expired battery.Check battery expiration date. Contact ACR support for battery replacement.

8. Specifikationer

9. Hvad er der i æsken

10. Garanti og support

ACR Electronics, Inc. stands behind the quality and reliability of its products. For specific warranty details, service, or technical support, please refer to the official ACR webhjemmeside eller kontakt deres kundeservice direkte.

Besøg ACR-butik på Amazon for mere information og produkttilbud.

11. Vigtige sikkerhedsoplysninger

The ACR ResQLink 400 is a critical safety device. It is subject to regulations by various authorities, including Cospas-Sarsat and the FCC. Always ensure your device is properly registered and maintained according to local and international guidelines. This device is intended for emergency use only. False activation can result in penalties.

Juridisk ansvarsfraskrivelse: Cospas-Sarsat, FCC

Relaterede dokumenter - PLB-400

Preview ACR ResQLink PLB installationsvejledning til Atlas 190 UML redningsvest
Trinvise instruktioner til montering af en ACR ResQLink personlig lokaliseringssignal (PLB) på en Atlas 190 UML redningsvest, der sikrer sikker og korrekt funktionalitet.
Preview ACR ResQlink AIS monteringsvejledning til Atlas 190 Hammar redningsvest
Trin-for-trin-guide til montering af en ACR ResQlink AIS personlig lokaliseringssignal (PLB) på en Mustang Survival Atlas 190 Hammar redningsvest, der sikrer korrekt og sikker installation i nødsituationer.
Preview Instruktioner til ACR AISLink MOB til ELITE 190 oppustelig redningsvest
Trin-for-trin-guide til, hvordan man monterer en ACR AISLink MOB-enhed på en ELITE 190 oppustelig redningsvest, hvilket sikrer sikker og korrekt funktion.
Preview Monterings- og installationsvejledning til ACR RCL-300A søgelys
Omfattende vejledning til montering og installation af ACR RCL-300A søgelyssystemet, inklusive URC-300 mastercontroller og URC-102 punktpude, med detaljerede ledningsføringsinstruktioner og funktioner.
Preview ACR Kelowna gaskomfurmanual: Installation, drift og vedligeholdelse
Omfattende bruger- og installationsmanual til ACR Kelowna gaskomfur (model 12H, G20 ved 20 mbar), der dækker opsætning, betjening, tekniske specifikationer, rengøring, vedligeholdelse, fejlfinding, fejlkoder og garantioplysninger.
Preview ACR Electric SEREN Komfur Installations- og Brugermanual
Omfattende installations- og brugermanual til ACR Electric SEREN komfurserien (SEREN-70, SEREN-130, SEREN-150), der dækker opsætning, betjening, vedligeholdelse, fejlfinding og garantioplysninger.