1. Introduktion
This user manual provides comprehensive instructions for the installation, operation, and maintenance of your ComfortStar Mini Split Single Zone Heat Pump. This system is designed to provide efficient heating and cooling for your space. Please read this manual thoroughly before operating the unit to ensure proper function and safety.
The ComfortStar Mini Split system is known for its energy efficiency, quiet operation, and ability to provide comfort even in extreme temperatures, down to -13°F (-25°C) for heating. It utilizes R410A refrigerant, which is environmentally friendly.
2. Sikkerhedsoplysninger
Always observe the following basic precautions to reduce the risk of fire, electric shock, or injury to persons or property:
- Professionel installation: Installation og vedligeholdelse må kun udføres af kvalificeret personale.
- Strømforsyning: Ensure the power supply matches the unit's specifications. Do not operate with damaged power cords or plugs.
- Ventilation: Bloker ikke enhedens luftindtag eller -udtag.
- Vandeksponering: Do not expose the indoor unit to water. Do not operate with wet hands.
- Børn og kæledyr: Hold børn og kæledyr væk fra enheden under drift.
- Rensning: Afbryd strømmen før rengøring eller udførelse af vedligeholdelse.
- Kølemiddel: The system contains R410A refrigerant. Do not attempt to service the refrigerant circuit yourself.
3. Produktet er slutview og komponenter
Your ComfortStar Mini Split system consists of an indoor unit, an outdoor unit, and a remote control. Understanding each component is key to proper operation.

Figure 3.1: Complete ComfortStar Mini Split System. This image displays the indoor wall-mounted unit, the outdoor condenser unit, and the wireless remote control, providing a comprehensive view af hovedkomponenterne.
3.1. Indendørsenhed
The indoor unit is typically mounted on a wall and is responsible for circulating conditioned air within your space. It contains the evaporator coil, fan, and air filter.

Figure 3.2: ComfortStar Indoor Unit. This image shows the sleek, white indoor unit designed for wall mounting, which houses the fan and evaporator coil.
3.2. Udendørsenhed
The outdoor unit, or condenser, is placed outside your building. It contains the compressor, condenser coil, and expansion valve. It is responsible for releasing or absorbing heat from the outdoor air.

Figure 3.3: ComfortStar Outdoor Unit. This image displays the robust outdoor condenser unit, which contains the compressor and is responsible for heat exchange with the outside environment.
3.3. Fjernbetjening
The wireless remote control allows you to conveniently adjust settings such as mode, temperature, fan speed, and timer functions from anywhere within range.

Figure 3.4: ComfortStar Remote Control. This image shows the ergonomic remote control with an LCD display and various buttons for controlling the mini split system's functions.
4. Opsætning og installation
The ComfortStar Mini Split system requires professional installation. This section provides an overview of the installation process. Do not attempt to install the unit yourself unless you are a certified HVAC technician.
4.1. Tjekliste før installation
- Verify that the electrical supply meets the unit's requirements (voltage, amperage).
- Ensure adequate space for both indoor and outdoor units, allowing for proper airflow and maintenance access.
- Confirm that the wall for the indoor unit is strong enough to support its weight.
- Gather necessary tools and materials (e.g., mounting brackets, refrigerant lines, electrical wiring).
4.2. General Installation Steps (Professional Only)
- Mount the indoor unit securely on the wall, ensuring it is level.
- Install the outdoor unit on a stable, level surface, ensuring proper drainage.
- Connect the refrigerant lines between the indoor and outdoor units. Ensure proper flaring and tightening to prevent leaks.
- Connect the electrical wiring between the units and to the main power supply, following local electrical codes.
- Tøm kølemiddelledningerne for at fjerne luft og fugt.
- Perform a leak test on all connections.
- Release the refrigerant into the system.
- Test the unit's operation in all modes.
For detailed installation instructions, refer to the separate installation manual provided with the unit or consult a certified HVAC professional.
5. Betjeningsvejledning
This section explains how to use your remote control to operate the ComfortStar Mini Split system.
5.1. Fjernbetjeningsfunktioner
The remote control features an LCD display and various buttons for easy operation:
- ON/OFF knap: Tænder eller slukker for enheden.
- TEMP +/- knapper: Justerer den ønskede temperatur.
- MODE knap: Cycles through operating modes (Auto, Cool, Dry, Heat, Fan).
- FAN SPEED knap: Justerer ventilatorhastigheden (Auto, Lav, Mellem, Høj).
- SWING knap: Controls the vertical louver swing for air direction.
- TIMER TIL/FRA-knapper: Sets the timer for automatic power on/off.
- SLEEP knap: Aktiverer dvaletilstand for stille drift og energibesparelse under søvn.
- TURBO knap: Aktiverer hurtig afkøling eller opvarmning til hurtige temperaturændringer.
- SELVRENS-knap: Initiates the self-cleaning function for the indoor unit.
- LED knap: Turns the indoor unit's display LED on or off.
- FØLG MIG-knap: Activates the "Follow Me" function, where the remote control's sensor measures the temperature and adjusts the unit accordingly.
- LÅS -knap: Locks the remote control buttons to prevent accidental changes.
- Genstarts knap: Resets the remote control settings.
5.2. Driftstilstande
- Automatisk tilstand:
- The unit automatically selects the appropriate operating mode (Cool, Heat, or Fan) based on the room temperature and your set temperature.
- Cool tilstand:
- Cools the room to the desired temperature. Adjust temperature using TEMP +/- buttons.
- Tørretilstand (affugtning):
- Reducerer luftfugtigheden i rummet. Ventilatorhastigheden styres automatisk.
- Varmetilstand:
- Heats the room to the desired temperature. This unit is a heat pump, providing efficient heating even in low ambient temperatures.
- Ventilatortilstand:
- Circulates air without heating or cooling. You can adjust the fan speed.
6. Vedligeholdelse
Regular maintenance ensures optimal performance and longevity of your ComfortStar Mini Split system. Always disconnect power before performing any maintenance.
6.1. Rengøring af luftfilter
The electrostatic carbon active fiber filter should be cleaned regularly, typically every 2-4 weeks, depending on usage and air quality.
- Åbn frontpanelet på indendørsenheden.
- Fjern forsigtigt luftfiltrene.
- Rengør filtrene med en støvsuger, eller vask dem med lunkent vand og et mildt rengøringsmiddel.
- Allow the filters to dry completely in a shaded area before reinserting them. Do not expose to direct sunlight.
- Sæt filtrene i igen, og luk frontpanelet.
6.2. Rengøring af udendørsenhed
Periodically check the outdoor unit for debris (leaves, dirt) that may obstruct airflow. Clean the coils gently with a soft brush or water hose. Ensure the area around the outdoor unit is clear of obstructions.
6.3. Professionel service
It is recommended to have your system professionally inspected and serviced annually by a qualified HVAC technician. This includes checking refrigerant levels, electrical connections, and overall system performance.
7. Fejlfinding
Før du kontakter kundesupport, bedes du se følgende tabel for almindelige problemer og løsninger på disse.
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Enheden tænder ikke. | Ingen strømforsyning; Fjernbetjeningens batterier er døde; Afbryderen er udløst. | Kontroller strømforbindelsen; Udskift fjernbetjeningens batterier; Nulstil afbryderen. |
| Utilstrækkelig køling/opvarmning. | Dirty air filter; Blocked outdoor unit; Incorrect mode setting; Low refrigerant. | Clean air filter; Clear obstructions from outdoor unit; Select correct mode; Contact professional for refrigerant check. |
| Usædvanlig støj. | Løse dele; Blokering af ventilator; Problem med kompressor. | Check for loose parts; Remove obstruction; Contact professional if compressor noise. |
| Vandlækage fra indendørsenheden. | Tilstoppet afløbsrør; Forkert installation. | Clear drain pipe; Contact professional for installation check. |
| Fjernbetjening virker ikke. | Løse batterier; Forhindring mellem fjernbetjening og enhed; Fjernbetjening uden for rækkevidde. | Replace batteries; Remove obstruction; Move closer to unit. |
Hvis problemet fortsætter efter at have forsøgt disse løsninger, bedes du kontakte en kvalificeret servicetekniker.
8. Specifikationer
Key technical specifications for the ComfortStar Mini Split Single Zone Heat Pump, Model CFS-CXH24CDI/24CDO:
- Model: CFS-CXH24CDI/24CDO
- Kapacitet: 24,000 BTU (2 Toneladas)
- SEER (Seasonal Energy Efficiency Ratio): Op til 25
- Kølemiddel: R-410A
- Speciel funktion: Opvarmning (varmepumpe)
- Low Ambient Operation: Capable of heating down to -13°F (-25°C)
- Filtertype: Electrostatic Carbon Active Fiber Filter
- Strømkilde: Kablet elektrisk
- Formfaktor: Minisplit
- Støjniveau: Super quiet technology
- Timer: 24-timers timerfunktion
- Automatisk genstart: Ja
9. Garanti og support
ComfortStar provides a limited warranty for this product:
- Kompressor garanti: 7 år
- Dele garanti: 5 år
For warranty claims, technical support, or service inquiries, please contact your authorized ComfortStar dealer or the customer service number provided with your purchase documentation. Ensure you have your model number (CFS-CXH24CDI/24CDO) and proof of purchase readily available.