1. Introduktion
This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Mirage Inverter X Air Conditioner, Model 3. Please read this manual thoroughly before using the unit and retain it for future reference.
2. Sikkerhedsoplysninger
Vigtige sikkerhedsinstruktioner:
- Ensure the unit is installed by a qualified professional in accordance with local electrical and building codes.
- Do not operate the air conditioner with wet hands or when standing on a wet surface.
- Afbryd strømmen, før du udfører vedligeholdelse eller rengøring.
- Keep children away from the unit and do not allow them to play with the controls.
- Stik ikke genstande ind i luftudløbet eller -indtaget.
- Use only the specified refrigerant (R-410A).
3. Produktet er slutview
The Mirage Inverter X Air Conditioner is a compact, wall-mounted mini-split system designed for efficient cooling. It features Inverter technology for stable temperature control and energy efficiency.
Figur 3.1: Front view of the Mirage Inverter X indoor air conditioner unit. The unit is white with the "Mirage" logo on the left and "INVERTER X" on the right.
Nøglefunktioner:
- Inverter Compressor for enhanced efficiency and stable temperature.
- 1 Ton (12,000 BTU) cooling capacity.
- SEER16 rating for energy savings.
- Antimicrobial Air Filter for improved air quality.
- Designed for 220V electrical systems.
4. Opsætning og installation
Installation of this air conditioning unit requires specialized tools and knowledge. It is strongly recommended that installation be performed by a certified HVAC technician to ensure proper function, safety, and warranty validity.
Generelle installationsovervejelser:
- Beliggenhed: Choose a location for the indoor unit that allows for optimal air distribution and easy access for maintenance. The outdoor unit should be placed on a stable surface with adequate clearance for airflow.
- Elektrisk tilslutning: The unit requires a dedicated 220V power supply. Ensure the electrical circuit meets the unit's power requirements and is protected by appropriate circuit breakers.
- Kølemiddelrør: Proper sizing and installation of refrigerant lines are crucial for system performance. The system uses R-410A refrigerant.
- Dræning: Ensure proper condensate drainage to prevent water damage.
5. Betjeningsvejledning
Your Mirage Inverter X Air Conditioner is controlled via a remote control. Familiarize yourself with the remote's functions for optimal use.
Grundlæggende driftstilstande:
- Cool tilstand: Indstiller enheden til at køle rummet ned til den ønskede temperatur.
- Ventilatortilstand: Cirkulerer luft uden afkøling eller opvarmning.
- Tør tilstand: Reducerer luftfugtigheden i rummet.
- Automatisk tilstand: Vælger automatisk driftstilstand baseret på rumtemperaturen.
- Temperaturindstilling: Use the temperature adjustment buttons to set your desired room temperature.
Refer to your remote control's specific manual for detailed instructions on advanced features such as timer settings, sleep mode, and fan speed adjustments.
6. Vedligeholdelse
Regular maintenance ensures the longevity and efficiency of your air conditioner. Always disconnect power to the unit before performing any maintenance.
Filterrensning:
- Åbn frontpanelet på indendørsenheden.
- Carefully remove the antimicrobial air filter(s).
- Clean the filter(s) using a vacuum cleaner or wash with lukewarm water and a mild detergent. Rinse thoroughly.
- Allow the filter(s) to dry completely in a shaded area before reinserting.
- Luk frontpanelet.
Frekvens: Rengør filtrene hver anden uge eller oftere afhængigt af brug og luftkvalitet.
Generel rengøring:
- Tør ydersiden af indendørs- og udendørsenhederne af med en blød, tør klud.amp klæde. Brug ikke skrappe kemikalier eller slibende rengøringsmidler.
- Ensure the outdoor unit's coils are free from debris (leaves, dirt). This may require professional cleaning.
Professionel servicering: It is recommended to have your unit professionally serviced annually to check refrigerant levels, clean coils, and inspect electrical components.
7. Fejlfinding
Før du kontakter kundesupport, skal duview følgende almindelige problemer og løsninger:
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Enheden starter ikke | Ingen strøm; afbryderen er udløst; fjernbetjeningens batterier er lave. | Kontroller strømforsyningen; nulstil afbryderen; udskift batterierne i fjernbetjeningen. |
| Utilstrækkelig køling | Dirty air filter; blocked outdoor unit; wrong mode selected; temperature setting too high. | Clean air filter; clear obstructions from outdoor unit; select Cool mode; lower temperature setting. |
| Usædvanlig støj | Loose parts; foreign objects; unit not level. | Inspect for loose parts; remove foreign objects; ensure unit is level. If noise persists, contact service. |
| Vandlækage fra indendørsenhed | Blocked drain pipe; improper installation. | Kontroller og rens afløbsrøret; kontakt installatøren for inspektion. |
Hvis problemet fortsætter efter at have forsøgt disse løsninger, bedes du kontakte kvalificeret servicepersonale.
8. Specifikationer
| Feature | Detalje |
|---|---|
| Mærke | Mirage |
| Modelnummer | 3 |
| Kapacitet | 1 tons (12,000 BTU) |
| Voltage | 220 volt |
| Strøm/Wattage | 230 |
| Sæsonbestemt energieffektivitetsforhold (SEER) | 16 |
| Speciel funktion | Inverter kompressor |
| Kølemiddel | R-410A |
| Filtertype | Antimikrobielt luftfilter |
| Produktmål (indendørsenhed) | 27D x 70B x 83H Centimeter |
| Varens vægt | 10.6 kg |
| Farve | Hvid |
9. Garanti og support
For warranty information and customer support, please refer to the documentation provided with your purchase or contact Mirage customer service. Keep your proof of purchase for warranty claims.
For technical assistance or service requests, please have your model number (Model 3) and serial number ready when contacting support.