1. Produktet er slutview

The PEDROLLO Presscontrol Easy Press II is an advanced electronic device designed to automate the operation of single-phase electric pumps up to 2 HP. It manages the pump's start and stop functions based on water demand, activating the pump when a tap is opened and deactivating it when the tap is closed.

Equipped with microprocessor logic, the Easy Press II offers crucial protection features. It safeguards the pump against dry running, automatically or manually resetting the system after a dry-run event. Furthermore, it prevents excessively frequent pump starts, which can occur due to minor leaks in the water system, thereby extending the pump's lifespan and ensuring stable water pressure.

PEDROLLO Presscontrol Easy Press II Electronic Pressure Regulator

Figur 1: Forside view of the PEDROLLO Presscontrol Easy Press II.

This image shows the compact design of the Easy Press II, featuring a pressure gauge, status indicators (Power, Out of Service, Dry, Running, Frequent Start-up), and the Pedrollo branding. The device is primarily white and blue with orange accents.

2. Nøglefunktioner

  • Automatic Pump Control: Starts and stops single-phase electric pumps based on water demand.
  • Tørløbsbeskyttelse: Microprocessor logic prevents pump damage from operating without water, with automatic or manual reset.
  • Lækagebeskyttelse: Protects the pump from frequent starts caused by small system leaks.
  • Integrated Pressure Gauge: Allows for easy monitoring of system pressure.
  • Høj beskyttelsesvurdering: IP 65 rated for dust and water resistance, suitable for various environments.
  • Robust design: Constructed from durable plastic material.

3. Specifikationer

AttributVærdi
FabrikantPEDROLLO
ModelEasy Press II
Max flowhastighed200 liter pr. minut (12 m³/t)
Driftstryk10 bar
Starttryk1.5 bar
Liquid Temperature LimitOp til +65 °C
Ambient Temperature LimitOp til +40 °C
Burst Pressure> 40 bar
BeskyttelsesvurderingIP 65
Voltage230 V
Frekvens50/60 Hz
Maks. Strøm16 A (for Easy Press II)
Varens vægt2 kilo
FarveOrange
MaterialePlast
StrømkildeEl-kabel

4. Sikkerhedsoplysninger

Always read and understand all safety warnings and instructions before installing, operating, or maintaining the PEDROLLO Presscontrol Easy Press II. Failure to follow these instructions could result in electric shock, fire, serious injury, or property damage.

  • Ensure the power supply matches the device's specifications (230V, 50/60Hz).
  • All electrical connections must be performed by a qualified electrician and comply with local electrical codes.
  • Afbryd strømmen, før du udfører installation, vedligeholdelse eller fejlfinding.
  • Do not operate the device if it is damaged or if the power cable is frayed.
  • Hold børn og uautoriseret personale væk fra installationsområdet.
  • Sørg for korrekt jording for at forhindre elektriske farer.

5. Installation og opsætning

The Easy Press II is designed for easy integration into single-phase electric pump systems. Proper installation is crucial for optimal performance and safety.

  1. Montering: Install the Easy Press II vertically, ensuring the flow direction matches the arrows on the device. It should be mounted between the pump and the first point of water consumption.
  2. Hydraulisk tilslutning: Connect the inlet of the Easy Press II to the pump's discharge and the outlet to the system's piping. Ensure all connections are watertight using appropriate sealants (e.g., PTFE tape).
  3. Elektrisk tilslutning:
    • Connect the power supply cable to the Easy Press II's input terminals.
    • Connect the pump's power cable to the Easy Press II's output terminals.
    • Ensure all connections are secure and properly insulated. Refer to the wiring diagram provided in the technical documentation (Figure 2).
  4. Klargøring af systemet: Before starting the pump, ensure the pump and the Easy Press II are fully primed with water to prevent dry running.
  5. Indledende opstart: Once all connections are secure and the system is primed, restore power. The Easy Press II will initiate the pump when water demand is detected.
PEDROLLO Presscontrol Easy Press II Technical Diagram and Dimensions

Figure 2: Technical diagram and dimensions of the PEDROLLO Easy Press II.

This image provides detailed technical specifications, performance curves, and dimensional drawings for the Easy Press II. It illustrates various models (Easy Press 1, Easy Press 2) and their electrical characteristics, as well as typical installation setups and physical dimensions.

6. Betjening

The PEDROLLO Easy Press II operates automatically once installed and powered. It functions as an electronic flow and pressure switch.

  • Pump Start: When a tap or valve in the system is opened, causing a drop in pressure and flow, the Easy Press II detects this demand and automatically starts the connected electric pump.
  • Pump Stop: When all taps or valves are closed, and water flow ceases, the Easy Press II detects the absence of flow and stops the pump after a short delay, maintaining system pressure.
  • Statusindikatorer: The device features LED indicators (Power, Out of Service, Dry, Running, Frequent Start-up) to provide visual feedback on its operational status. Refer to the device's front panel for specific indicator meanings.

7. Vedligeholdelse

The PEDROLLO Easy Press II is designed for minimal maintenance. However, regular checks can help ensure its longevity and reliable operation.

  • Regelmæssig inspektion: Periodically check the device and its connections for any signs of leaks, damage, or corrosion.
  • Renhed: Keep the exterior of the device clean and free from dust or debris. Do not use abrasive cleaners.
  • Vinterisering (hvis relevant): In areas subject to freezing temperatures, ensure the device and connected piping are drained or protected from frost to prevent damage.
  • Kontrol af trykmåler: Monitor the pressure gauge regularly to ensure it is functioning correctly and providing accurate readings.

Always disconnect power to the device before performing any maintenance or inspection.

8. Fejlfinding

The Easy Press II incorporates intelligent features to protect the pump and indicate operational issues. Here are common scenarios and their resolutions:

  • Pump Not Starting / "Dry" Indicator On:
    • Årsag: Dry running detected (no water in the pump or suction line).
    • Løsning: Ensure the pump is primed with water. The Easy Press II may attempt an automatic reset after a period. If not, manually reset the device by pressing the "START/STOP" button or by cycling the power.
  • Pump Cycling Frequently / "Frequent Start-up" Indicator On:
    • Årsag: Small leaks in the system (e.g., dripping tap, faulty toilet fill valve) or a non-return valve issue.
    • Løsning: Inspect all plumbing fixtures and connections for leaks. Repair any leaks found. Check the non-return valve in the system for proper operation.
  • Pump Not Stopping:
    • Årsag: Continuous water flow (e.g., open tap, major leak) or a sensor malfunction.
    • Løsning: Close all taps and check for significant leaks. If the pump continues to run without demand, disconnect power and contact a qualified technician.
  • No Power / "Power" Indicator Off:
    • Årsag: No electrical supply to the device.
    • Løsning: Check the circuit breaker, fuses, and power connections. Ensure the power outlet is functional.

For issues not covered here, or if troubleshooting steps do not resolve the problem, contact a qualified technician or the manufacturer's support.

9. Garanti og support

Information regarding the specific warranty period and terms for the PEDROLLO Presscontrol Easy Press II is typically provided at the point of purchase or within separate documentation accompanying the product. Please retain your proof of purchase for warranty claims.

For technical support, spare parts, or service inquiries, please contact your authorized PEDROLLO dealer or the manufacturer directly. Information on spare parts availability was not provided in the product details.

Manufacturer: PEDROLLO

Relaterede dokumenter - Easy Press II

Preview Pedrollo PRESFLO MULTI automatisk styreenhed datablad
Teknisk datablad for Pedrollo PRESFLO MULTI, en elektronisk enhed til styring og beskyttelse af enfasede husholdningspumper. Detaljer om funktioner, specifikationer, installation og justering af vandforsynings- og kunstvandingssystemer.
Preview Pedrollo EP elektronisk pumpebeskytter: Installations- og betjeningsvejledning
Omfattende guide til Pedrollo EP elektronisk pumpebeskytter, med detaljerede oplysninger om dens funktioner til tørløb, overstrøm og voluminiumstemperatur.tage-beskyttelse, sammen med installations- og betjeningsvejledning.
Preview Pedrollo PRESFLO MULTI automatisk styreenhed - Tekniske specifikationer
Detaljerede tekniske specifikationer, installationsvejledning og funktioner for Pedrollo PRESFLO MULTI automatisk elektronisk trykreguleringsenhed til husholdningsvandforsyning og trykforøgelse.
Preview Pedrollo EP elektronisk beskyttelsesenhed - brugermanual og datablad
Omfattende guide til Pedrollo EP elektronisk beskyttelsesenhed, med detaljerede oplysninger om dens funktioner, tekniske specifikationer, installation og drift. Beskytter pumper mod tørløb, overstrøm og overspænding.tage, og undervoltage. Velegnet til husholdningsbrug.
Preview Pedrollo E1-E2 Elektroniske Elpaneler til Pumper
Omfattende guide til Pedrollo E1 og E2 elektroniske kontrolpaneler, designet til styring af enkelt- eller dobbeltpumpesystemer i private, kommercielle og industrielle miljøer. Funktionerne omfatter valgbare driftstilstande, tørløbsbeskyttelse og intuitive brugergrænseflader til effektiv pumpedrift.
Preview Pedrollo TOP MULTI-TECH / TOP MULTI-EVOTECH Automatisk Dykpumpe Brugsanvisning
Dette dokument indeholder betjeningsvejledning til de automatiske nedsænkbare multi-sejlere Pedrollo TOP MULTI-TECH og TOP MULTI-EVOTECHtage vandpumper. Den dækker generelle oplysninger, driftsprincipper, installationsråd og beskyttelsesfunktioner for optimal ydeevne og levetid.