Intermatic ET2105CR

Brugermanual til den elektroniske timer fra Intermatic

Model: ET2105CR

Mærke: Intermatic

1. Introduktion

This manual provides detailed instructions for the installation, operation, and maintenance of the Intermatic Electronic Timer, Model ET2105CR. This electronic timer is designed for precise control of electrical loads, offering 24-hour and 365-day operation modes. It features a single channel with SPST contact form, capable of handling 30 Amps at 120 to 277Vac voltage.

Intermatic Electronic Timer in a gray metal enclosure

Figure 1: Intermatic Electronic Timer, Model ET2105CR, enclosed in a durable gray metal casing.

The timer is housed in a NEMA 3R rated metal enclosure, suitable for outdoor use, and includes a capacitor backup for up to 100 hours of operation during power outages. Please read this manual thoroughly before installation and operation to ensure safe and efficient use of the device.

2. Sikkerhedsoplysninger

Overhold altid følgende sikkerhedsforanstaltninger for at mindske risikoen for brand, elektrisk stød eller personskade:

  • ADVARSEL: Risk of Electric Shock. Disconnect power at the circuit breaker or fuse before installing or servicing.
  • Installation og ledningsføring skal udføres af en kvalificeret elektriker i overensstemmelse med alle lokale og nationale el-forskrifter.
  • Do not exceed the maximum electrical ratings of the device (30 Amps, 120-277Vac).
  • Sørg for korrekt jording for at forhindre elektrisk stød.
  • Do not use this device for applications where failure could result in dangerous conditions (e.g., medical life support equipment).
  • Keep the enclosure door closed and secured to maintain NEMA 3R rating and protect internal components.

3. Opsætning og installation

3.1 Montering af timeren

The ET2105CR timer is designed for surface mounting. Choose a suitable location that is accessible for wiring and programming, and protected from direct physical damage. Ensure the mounting surface is stable and can support the weight of the timer.

  1. Åbn døren til timerkabinettet.
  2. Locate the mounting holes on the back of the enclosure.
  3. Using appropriate screws and anchors (not supplied), securely fasten the timer to the desired surface.
  4. Ensure the timer is level and firmly attached.

3.2 Ledningsinstruktioner

All wiring must comply with the National Electrical Code (NEC) and local codes. Refer to the wiring diagram inside the timer enclosure for specific connections.

  1. ENSURE POWER IS DISCONNECTED AT THE SOURCE BEFORE WIRING.
  2. Route the incoming power supply wires (LINE) and the load wires (LOAD) into the timer enclosure through appropriate conduit openings.
  3. Connect the LINE wires to the designated LINE terminals on the timer.
  4. Connect the LOAD wires to the designated LOAD terminals on the timer.
  5. Connect the ground wire to the ground terminal within the enclosure.
  6. Dobbelttjek alle forbindelser for tæthed og korrekt polaritet.
  7. Luk og fastgør kabinetdøren.

4. Betjeningsvejledning

4.1 Initial Power-Up and Display

Once wired and power is restored, the timer's display (1" height, 3" width) will illuminate. The internal capacitor will begin charging, providing backup power for settings retention during power outages.

4.2 Setting Current Time and Date

Before programming ON/OFF events, set the current time and date accurately.

  1. Press the "MENU" button to access the main menu.
  2. Navigate to "SET TIME/DATE" using the arrow buttons.
  3. Press "ENTER" to confirm.
  4. Adjust the year, month, day, hour, and minute using the arrow buttons and confirm each setting with "ENTER".

4.3 Programmering af TIL/FRA-hændelser

The timer supports up to 96 ON/OFF cycles. Each event can be programmed for specific days of the week or daily operation.

  1. From the main menu, navigate to "PROGRAM EVENTS".
  2. Select "ADD NEW EVENT".
  3. Choose "ON" or "OFF" for the event type.
  4. Set the desired time (hour and minute) for the event.
  5. Select the days of the week for the event to be active (e.g., Mon-Fri, Daily, or specific days).
  6. Confirm the event. Repeat for all desired ON and OFF cycles.

4.4 Manuel tilsidesættelse

The timer allows for temporary manual override of programmed events.

  • Press the "MANUAL" button to toggle the output state (ON/OFF) without affecting the programmed schedule.
  • The timer will revert to the programmed schedule at the next scheduled event.

5. Vedligeholdelse

The Intermatic Electronic Timer is designed for minimal maintenance. However, periodic checks can ensure optimal performance and longevity.

  • ADVARSEL: Afbryd strømmen, før du udfører nogen form for vedligeholdelse.
  • Rensning: Periodically wipe the exterior of the enclosure with a soft, damp klæde. Brug ikke slibende rengøringsmidler eller opløsningsmidler.
  • Inspektion: Annually inspect the wiring connections for tightness and signs of corrosion or damage. Ensure the enclosure door seal is intact to maintain its NEMA 3R rating.
  • Batteri-sikkerhedskopi: The internal capacitor provides backup for settings. If the timer frequently loses its settings after power outages, the capacitor may need servicing by a qualified technician.

6. Fejlfinding

Se tabellen nedenfor for almindelige problemer og deres løsninger.

Problem Mulig årsag Løsning
Timerdisplayet er tomt. Ingen strøm til timeren. Check circuit breaker/fuse. Verify wiring connections.
Timer does not switch load ON/OFF as programmed. Incorrect programming; Manual override active; Wiring issue. Review programmed events. Check if manual override is engaged. Verify load wiring.
Timeren mister indstillinger efter strømafbrydelsetage. Capacitor backup not fully charged or failing. Allow timer to remain powered for 24 hours to fully charge capacitor. If issue persists, contact qualified service personnel.
Enclosure shows signs of water ingress. Damaged enclosure seal or improper installation. Inspect enclosure for cracks or damage. Ensure door is properly latched and seal is intact. Re-seal or replace if necessary.

7. Specifikationer

Feature Detalje
Modelnummer ET2105CR
Driftstilstand 24 timer / 365 dage
Antal kanaler 1
Kontaktformular SPST
Voltage 120 til 277Vac
Ampslette 30 Amps
Max. ON/OFF Cycles 96
Indhegning Metal, NEMA 3R Rated
Montering Overflade
Min. Time Setting 1 minut
Maks. Tidsindstilling 24 timer
Sikkerhedskopienhed Kondensator
Backup tid 100 timer
Driftstemperatur -40°F til 155°F (-40°C til 68°C)
Skærmmål 1" Height x 3" Width
Produktmål (H x B x D) 10-1/8" x 6-1/2" x 3-5/8" (10.13" x 6.5" x 3.63")
Vægt 3.32 pund
Standarder UL Listed, California Title 20 Listed, LED Listed
UPC 078275147966
Intermatic Electronic Timer with dimensions labeled: 10.12 inches height, 6.5 inches width, 3.62 inches depth.

Figure 2: Dimensions of the Intermatic Electronic Timer, Model ET2105CR.

8. Garanti og support

8.1 Garantioplysninger

Intermatic products are manufactured under strict quality standards. For specific warranty terms and conditions applicable to your ET2105CR Electronic Timer, please refer to the warranty card included with your product or visit the official Intermatic website. Warranty coverage typically includes defects in material and workmanship for a specified period from the date of purchase.

8.2 Teknisk support

If you encounter any issues not covered in the troubleshooting section or require further assistance, please contact Intermatic Customer Support. Have your model number (ET2105CR) and purchase information ready when contacting support.

For the most current contact information, please visit the official Intermatic webwebstedet eller se emballagen på dit produkt.

Note: Protection plans offered by third-party sellers are separate from the manufacturer's warranty.

Relaterede dokumenter - ET2105CR

Preview Intermatic HB880R Udendørs 7-dages digital timer: Brugsanvisning og opsætningsvejledning
Omfattende brugermanual til Intermatic HB880R udendørs 7-dages digital timer. Lær, hvordan du installerer, programmerer, indstiller tidsplaner og fejlfinder denne alsidige tidsafbryder.
Preview Intermatic EI200 elektronisk nedtællingstimer til vægmontering Installations- og betjeningsvejledning
Detaljeret vejledning til installation og betjening af den elektroniske vægindbyggede nedtællingstimer Intermatic EI200. Funktionerne omfatter tidsintervaller på 5-30 minutter, kontinuerlig HOLD-tilstand og klassificeringer for 15A universalmotorer, 1000W wolframmotorer og 1/4 HK-motorer. Indeholder garantioplysninger.
Preview Intermatic ET8215C Elektronisk Timerstyring - Tekniske Data
Detaljerede tekniske specifikationer for Intermatic ET8215C elektronisk timerstyring, en astronomisk 7-dages, 2-kreds elektronisk styring egnet til 120-277 VAC applikationer i et indendørs metalkabinet.
Preview Intermatic EI210 Elektronisk Nedtællingstimer til Indbygning i Væg - Installations- og Brugervejledning
Omfattende guide til den elektroniske vægindbyggede nedtællingstimer Intermatic EI210, med detaljerede funktioner, installationstrin, driftstilstande (Timer og Hold) og garantioplysninger. Indeholder tekniske specifikationer og kontaktoplysninger for Intermatic Incorporated.
Preview Intermatic EI205 Elektronisk Nedtællingstimer til Indbygning i Væg: Installations- og Brugervejledning
Omfattende vejledning til installation og betjening af den elektroniske vægindbyggede nedtællingstimer Intermatic EI205. Dækker funktioner, klassificeringer, trin-for-trin installation, driftstilstande og en 1-års begrænset garanti. Ideel til styring af belysning og belastninger med tidsindstillet slukning.
Preview Intermatic EJ351 Indendørs vægafbrydertimer: Installations- og brugervejledning
Dette dokument indeholder installations- og brugervejledning til Intermatic EJ351 indendørs vægafbrydertimer. Det dækker specifikationer, ledningsføring, programmeringsmetoder (hurtig og 24-timers), daglig brug, fejlfinding og en begrænset garanti på et år.