Indledning
This manual provides essential information for the safe and proper installation, operation, and maintenance of your Bryant 9450FR Industrial Grade 50 Amp NEMA 14-50 Receptacle. Please read all instructions carefully before beginning any work.
Sikkerhedsoplysninger
ADVARSEL: Risk of electric shock or fire. Installation must be performed by a qualified electrician in accordance with all national and local electrical codes.
- Always disconnect power at the circuit breaker or fuse box before installing or servicing this receptacle.
- Kontroller, at strømmen er slukket ved hjælp af en voltage testeren, før du rører ved nogen ledninger.
- Sørg for korrekt jording for at forhindre elektrisk stød.
- Overskrid ikke den angivne voltage og amperage ratings of the receptacle.
- Use only appropriate tools and personal protective equipment (PPE).
Pakkens indhold
Kontroller, at alle komponenter er til stede og ubeskadigede, før du fortsætter med installationen.
- Bryant 9450FR NEMA 14-50 Receptacle
- Mounting Screws (typically included)
- Instruktionsark (denne manual)

Image: The Bryant 9450FR NEMA 14-50 Receptacle shown with the included mounting screws in clear plastic bags.
Opsætning (Installation)
This receptacle is designed for flush mounting. Follow these steps for proper installation:
- Forbered placeringen: Ensure you have a suitable electrical box (e.g., 4x4 square box with a 2-gang mud ring or a single-gang box with appropriate adapter) that can accommodate the receptacle and wiring.
- Sluk for strømmen: Locate the circuit breaker for the circuit you will be working on and switch it to the OFF position. Verify with a voltage tester that no power is present at the wires.
- Afisolér ledninger: Carefully strip approximately 3/4 inch (19mm) of insulation from the ends of the supply wires. For 14-50R, you will typically have two hot wires (black/red), one neutral wire (white), and one ground wire (green/bare copper).
- Tilslut ledninger: The Bryant 9450FR features clearly marked terminals.
- Tilslut GRØN or bare copper ground wire to the terminal marked "GREEN" (grounding screw).
- Tilslut HVID neutral wire to the terminal marked "WHITE" (neutral screw).
- Forbind de to VARMT wires (black and red) to the remaining two terminals marked "XXX" (line screws).

Billede: Bagside view of the receptacle showing the screw terminals labeled for proper wire connection (White, Green, and two Hot).
- Sikre forbindelser: Tighten all terminal screws firmly to ensure good electrical contact. Tug gently on each wire to confirm it is securely fastened.
- Monter stikkontakt: Carefully fold the wires into the electrical box. Align the receptacle with the mounting holes in the electrical box and secure it using the provided mounting screws. Do not overtighten.
- Install Faceplate (Not Included): Once the receptacle is securely mounted, install a compatible NEMA 14-50 faceplate (sold separately) over the receptacle.
- Gendan strøm: Go back to the circuit breaker or fuse box and switch the power back ON.

Billede: Forside view of the Bryant 9450FR NEMA 14-50 Receptacle, ready for faceplate installation.
Betjeningsvejledning
The Bryant 9450FR NEMA 14-50 Receptacle is designed for use with NEMA 14-50 compatible plugs. To operate:
- Ensure the appliance or device you intend to connect is rated for 125/250V and does not exceed 50 Amps.
- Align the prongs of the NEMA 14-50 plug with the corresponding slots on the receptacle.
- Firmly insert the plug into the receptacle until it is fully seated.
- To disconnect, firmly grasp the plug and pull it straight out from the receptacle. Do not pull by the cord.
Opretholdelse
The Bryant 9450FR receptacle requires minimal maintenance. Regular inspection is recommended:
- Undersøg regelmæssigt stikkontakten for tegn på skader, såsom revner, misfarvning eller løse forbindelser.
- Ensure the faceplate is securely attached.
- Keep the receptacle clean and free of dust or debris. Use a dry cloth for cleaning. Do not use liquid cleaners.
- If any damage is observed, disconnect power to the circuit and have the receptacle inspected and replaced by a qualified electrician.
Fejlfinding
If you experience issues with your receptacle, consider the following common troubleshooting steps:
| Problem | Mulig årsag | Løsning |
|---|---|---|
| No power from receptacle. | Strømafbryder udløst eller sikring sprunget. | Check and reset the circuit breaker or replace the fuse. If it trips repeatedly, consult an electrician. |
| Plug does not fit. | Incorrect plug type or foreign object in receptacle. | Ensure you are using a NEMA 14-50 compatible plug. Inspect slots for obstructions (with power off). |
| Receptacle feels warm. | Overload or loose connection. | Disconnect the load. If it persists, turn off power and have an electrician inspect wiring and connections. |
For issues not covered here, or if problems persist, contact a qualified electrician.
Specifikationer
| Modelnummer: | 9450FR |
| Type: | Industrial Grade 50 Amp NEMA 14-50 Receptacle |
| Voltage Bedømmelse: | 125/250V |
| Ampaldersvurdering: | 50 Amp |
| Poles/Wires: | 3 Pole, 4 Wire Grounding |
| Monteringstype: | Enkelt skylning |
| Materiale: | Nylon (housing) |
| Farve: | Sort |
| Fabrikant: | Bryant |
Garanti
This Bryant product is manufactured to high-quality standards. For specific warranty information, please refer to the documentation included with your purchase or visit the manufacturer's official webwebsted. Gem din købsbevis til garantikrav.
Støtte
For technical assistance or further inquiries, please contact the manufacturer or your authorized distributor. Always provide the model number (9450FR) when seeking support.
Fabrikant: Bryant (a Hubbell brand)
Webwebsted: www.hubbell.com/bryant/en





