Indledning
The XPOWER X-47ATR is a professional-grade axial air mover designed for commercial and industrial applications. This high-performance fan efficiently produces up to 3600 CFM (Cubic Feet per Minute) while maintaining a low 2.8 AMP draw. Its robust design, featuring a sealed motor and durable ABS injection-molded housing, ensures reliability in various demanding environments, including water damage restoration sites. The unit is equipped with variable speed control, a 3-hour timer, and a 360-degree rotation rack/stand for versatile positioning. Built-in daisy-chainable power outlets enhance its utility for multiple unit setups.
This manual provides essential information for the safe and efficient operation, maintenance, and troubleshooting of your XPOWER X-47ATR Axial Air Mover Fan.
Nøglefunktioner
- Høj luftstrømskapacitet: Produces up to 3600 CFM for rapid drying and ventilation.
- Energieffektiv: Lav 2.8 Amp draw maximizes efficiency.
- Sealed Motor: Protects against water, dust, and other contaminants, ideal for water damage restoration.
- Variabel hastighedskontrol: Allows precise adjustment of airflow for various applications and quiet operation in noise-sensitive environments.
- 3-timers timer: Convenient for timed operations.
- 360-Degree Rotation Rack/Stand: Enables versatile positioning to direct airflow precisely.
- Daisy-Chainable Power Outlets: Built-in outlets allow multiple units to be connected on a single 15-amp kredsløb.
- Focused Air Stream: Unique grill design extends a powerful and focused air stream up to 60 ft.
- Portable & Stackable: Lightweight ABS injection-molded housing allows for easy transport and stacking up to 5 units high for compact storage.
- Ducting Compatibility: Can be used with optional ducting hoses (16DH25 or 16DH15) and adapter kit (16DHK) for confined space ventilation.
Produkt overview

Figur 1: Forside view of the XPOWER X-47ATR Axial Air Mover Fan, showcasing its robust design and protective grille.

Figur 2: Side view of the XPOWER X-47ATR, highlighting the control panel with variable speed dial, timer, and integrated daisy-chainable power outlets.

Figure 3: Diagram illustrating the 360-degree rotational capability of the X-47ATR on its sturdy rack/stand, allowing for precise airflow direction.

Figure 4: Diagram depicting the focused air stream produced by the X-47ATR, capable of channeling air up to 60 feet for efficient drying.

Figure 5: Multiple XPOWER X-47ATR units stacked vertically, demonstrating their space-saving design for storage and transport.

Figure 6: The XPOWER X-47ATR connected to an optional yellow ducting hose, illustrating its use for confined space ventilation.
Opsætning
- Udpakning: Carefully remove the X-47ATR from its packaging. Inspect the unit for any signs of damage during transit.
- Placering: Position the air mover on a stable, level surface. Utilize the 360-degree rotation rack/stand to angle the fan as needed for optimal airflow direction. Ensure the fan is placed in a location that allows for proper air circulation and does not obstruct the intake or exhaust.
- Strømtilslutning: Connect the power cord to a standard 115 Volts (AC) outlet. The unit is designed for a low 2.8 Amp draw, allowing multiple units to be daisy-chained on a single 15-amp circuit if needed.
- Ducting (Optional): If using for confined space ventilation, attach the appropriate XPOWER ducting hose (e.g., 16DH25 or 16DH15) to the fan's inlet or outlet using the optional adapter kit (16DHK).
Betjeningsvejledning
Generel drift
- Tænd/sluk: Locate the power switch on the control panel. Turn the unit ON to begin operation.
- Variabel hastighedskontrol: Adjust the variable speed dial to achieve the desired airflow. The fan offers a full range of adjustable speeds, allowing for powerful air movement or quieter operation in noise-sensitive environments.
- Timer funktion: Use the 3-hour timer dial to set the desired operating duration. The fan will automatically shut off after the set time.
- Daisy-Chaining: For larger areas or increased airflow, connect additional XPOWER X-47ATR units using the built-in auxiliary power outlets. Ensure not to exceed the maximum amperage af kredsløbet.
Anbefalede anvendelser
- Tørring: Ideal for drying wet floors, carpets, walls, ceilings, furniture, paint, drywall, and cement. Position the fan to direct the focused air stream towards the affected area.
- Ventilation: Use for providing ventilation in confined spaces or improving air circulation. When used with ducting hoses, it can create negative air pressure for specific ventilation applications.
- Luftcirkulation: Enhance air movement in large rooms, workshops, or construction sites to improve comfort and air quality.
Operationelle videoer
Video 1: Overståetview of XPOWER Axial Fans, demonstrating their features and applications in various settings. This video highlights the efficiency and versatility of the X-47ATR and similar models.
Video 2: Detailed demonstration of the X-47ATR Axial Fan, showcasing its powerful airflow, sealed motor, adjustable rack, and variable speed control. This video illustrates practical uses in restoration and construction.
Opretholdelse
Regular maintenance ensures the longevity and optimal performance of your XPOWER X-47ATR Axial Air Mover Fan.
- Rensning: Periodically inspect the fan blades and grilles for dust and debris buildup. Clean monthly or as necessary, especially in dusty environments. Ensure the unit is unplugged before cleaning. Use a soft cloth or brush to remove accumulated dust. The sealed motor design helps protect internal components from contaminants.
- Motor smøring: For extended use, consider lubricating the motor shaft with a lightweight No. 2 oil during cleaning. This can help maintain smooth operation and prevent issues like squealing noises. Refer to a qualified technician if unsure about internal lubrication.
- Ledningspleje: Always wrap the power cord neatly around the designated cord wrap area when not in use to prevent damage. Avoid kinking or pulling the cord excessively.
- Opbevaring: When storing, stack units up to 5 high to maximize space. Ensure the units are clean and dry before storage.
Fejlfinding
If you encounter issues with your XPOWER X-47ATR, refer to the following common troubleshooting steps:
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Ventilatoren tænder ikke. | Ingen strøm, udløst afbryder, defekt afbryder. | Check power outlet. Reset circuit breaker on the unit or at the main panel. Ensure power switch is in the ON position. |
| Reduceret luftgennemstrømning. | Blocked intake/exhaust, dirty blades/grille. | Clear any obstructions. Unplug unit and clean fan blades and grilles. |
| Unusual noise (squealing, grinding). | Dust buildup in motor, worn bearings. | Unplug unit and clean thoroughly, especially around the motor shaft. If noise persists, professional servicing may be required. |
| Fan vibrates excessively. | Unbalanced blades, loose components, unstable surface. | Ensure unit is on a stable, level surface. Check for debris on blades that might cause imbalance. Tighten any loose screws or components. |
| Daisy-chained units not working. | Overloaded circuit, faulty connection. | Sørg for total amperage draw does not exceed circuit capacity (15 amps). Check connections between units. |
If the problem persists after attempting these solutions, please contact XPOWER customer support or a qualified service technician.
Specifikationer
| Specifikation | Detalje |
|---|---|
| Mærke | XPOWER |
| Modelnavn | X-47ATR |
| Elektrisk ventilator design | Gulv Fan |
| Strømkilde | Elektrisk med ledning |
| Luftmængde kapacitet | 3600 kubikfod pr. minut (CFM) |
| Wattage | 322 watt |
| Voltage | 115 volt (AC) |
| Maks Amp Tegne | 2.8 Amps |
| Speciel funktion | Portable, Lightweight, Variable Speed Control, 3-Hour Timer, Daisy-Chainable Outlets, 360-Degree Rotation |
| Anbefalede anvendelser | Exhausting, Drying |
| Indendørs/Udendørs brug | Indendørs |
| Kontrolmetode | Dial/Push Button |
| Bladmateriale | Plast |
| Materiale til hus | ABS Injection Molded |
| Stabelbarhed | Up to 5 units high |
| Vægt | Approx. 22 lbs (based on video information) |
| Specifikation Met | ETL/CETL Safety Certified |
Garanti og support
The XPOWER X-47ATR Axial Air Mover Fan comes with a 1 års begrænset producentgaranti. For warranty claims, technical support, or any inquiries not covered in this manual, please contact XPOWER Manufacture, Inc. customer service.
Gem venligst din købsbevis af garantihensyn.