KETOTEK KT-D138

KETOTEK KT-D138 DC 6.5-100V 100A Voltmeter Amperemeter Effekt Energimåler Brugermanual

Model: KT-D138 with 100A/75mV Shunt

1. Introduktion

This manual provides detailed instructions for the installation, operation, and maintenance of your KETOTEK KT-D138 DC Digital Voltmeter Ammeter Power Energy Meter. This device is designed to accurately measure DC voltage, current, active power, and energy consumption in various applications, including battery systems, solar power setups, and electric bicycle generators. Please read this manual thoroughly before use to ensure correct operation and prevent damage.

The KT-D138 is a 4-in-1 multimeter featuring a large LCD with backlight, voltage alarm function, energy reset, and data storage upon power-off. It is intended for indoor use only.

2. Produktet er slutview

2.1 Nøglefunktioner

  • 4-i-1-måling: Simultaneously displays DC voltage, current, active power, and energy.
  • Bredt måleområde: Voltage DC 6.5-100V, Current 0-100A, Power 0-10kW, Energy 0-9999kWh.
  • Ryd skærm: Large LCD with blue backlight for easy readability.
  • Voltage Alarm: Konfigurerbar voltage alarm threshold with display flashing.
  • Energy Reset: One-button reset for accumulated energy data.
  • Datalagring: Automatically saves measurement data when power is off.

2.2 Pakkens indhold

  • 1 x KETOTEK KT-D138 DC Multimeter
  • 1 x 100A/75mV Current Shunt
  • 1 x Brugermanual (dette dokument)
KETOTEK KT-D138 DC Voltmeter Ammeter with 100A Shunt

Image 1: KETOTEK KT-D138 DC Voltmeter Ammeter and included 100A/75mV shunt.

KETOTEK KT-D138 LCD display showing voltage, current, power, and energy ranges

Image 2: The KT-D138 display indicating measurement ranges for voltage (6.5-100V), current (0-100A), power (0-10kW), and energy (0-9999kWh).

3. Specifikationer

ParameterVærdi
Operation VoltageDC 6.5 - 100V
Nuværende måleområde0 - 100A
Active Power Measurement Range0 - 10 kW
Energy Measurement Range0 - 9999kWh
Målenøjagtighed1%
Display TypeLCD med blå baggrundsbelysning
Dimensioner (L x B x H)8.96 x 4.68 x 2.44 cm (3.53 x 1.84 x 0.96 tommer)
Vægt70 gram (2.47 oz)
DriftsmiljøKun indendørs brug
OverholdelseCE
KETOTEK KT-D138 dimensions diagram

Image 3: Dimensional drawing of the KETOTEK KT-D138 meter, showing measurements in millimeters.

4. Sikkerhedsoplysninger

  • Do Not Exceed Rated Parameters: Sørg for, at voltage and current of the circuit being measured do not exceed the specified ranges (DC 6.5-100V, 0-100A). Exceeding these limits can cause permanent damage to the device and potential safety hazards.
  • Korrekt ledningsføring: Always follow the provided wiring diagrams precisely. Incorrect wiring is a common cause of product malfunction or damage. If you are unsure about any connection, consult a qualified electrician or contact KETOTEK support.
  • Kun indendørs brug: This device is designed for indoor environments. Do not expose it to moisture, direct sunlight, extreme temperatures, or corrosive substances.
  • Professionel installation anbefales: For complex electrical systems, professional installation is recommended to ensure safety and proper functionality.
  • Undgå fysisk skade: Handle the meter with care. Avoid dropping or subjecting it to strong impacts.

5. Opsætning og installation

5.1 Wiring Diagram for Current Measurement with Shunt

The KT-D138 requires an external 100A/75mV shunt for current measurement. The shunt must be connected in series with the load. The meter's current sensing wires connect to the small terminals of the shunt, while the main power circuit connects to the large terminals.

Wiring diagram for KETOTEK KT-D138 with 100A shunt, power supply, and load

Image 4: Standard wiring diagram for the KT-D138 meter, showing connections to a power supply, 100A/75mV shunt, and a load. Note the distinction between large and small terminals on the shunt.

Vigtig: Distinguish between the large and small terminals of the shunt. The current sensor wires from the meter connect to the small terminals. The main power supply and load connect to the large terminals.

5.2 Solar System Wiring Instructions

The KT-D138 can be integrated into a solar power system to monitor various aspects. Below are examples of how to connect the instrument at different positions according to your specific monitoring needs.

Solar system wiring diagram with KETOTEK KT-D138 at four different monitoring points

Image 5: Comprehensive solar system wiring diagram illustrating four potential connection points for the KT-D138 meter to monitor different aspects of the system.

  • Position 1: Monitoring Charging Performance. When the battery is discharging, the meter displays 0. Energy accumulation stops. Energy starts accumulating when the battery is charging again.
  • Position 2: Monitoring Discharging Performance. When the battery is charging, the meter displays 0. Energy accumulation stops. Energy starts accumulating when the battery is discharging.
  • Position 3: Monitoring Solar System Power Generation. Connect the meter to measure the total power generated by the solar panels before the charge controller.
  • Position 4: Measuring Load Usage. Connect the meter to measure the power and energy consumed by an inverter or other loads connected to the battery.

6. Betjeningsvejledning

The KT-D138 features a single button on the right side of the display for various functions.

KETOTEK KT-D138 display with button functions indicated

Image 6: The KT-D138 meter highlighting the multi-function button for energy reset, backlight control, and voltage alarm settings.

  • Energy Reset: Press and hold the button for 5 seconds until the energy value (Wh) flashes. Release the button, then press it again briefly to reset the energy accumulation to zero.
  • Baggrundslys TIL/FRA: A short press of the button will toggle the backlight on or off.
  • Sæt Voltage Alarm Threshold: For at indstille voltage alarm, press and hold the button until the voltage value (V) flashes. Release the button. Each short press will increase the alarm threshold. Once the desired threshold is set, wait for 5 seconds without pressing any button, and the setting will be saved automatically. When the measured voltage falls below this threshold, the display will flash to indicate a low voltage alarm.

7. Fejlfinding

ProblemMulig årsagLøsning
No display/Meter not powering onIncorrect wiring; Input voltage outside range; Loose connections.Verify all wiring connections against the diagram. Ensure input voltage is within DC 6.5-100V. Check for secure connections.
Current reading is 0 or incorrectShunt not connected correctly; Current sensing wires reversed or loose; No load.Ensure the shunt is correctly installed in series with the load. Verify current sensing wires are connected to the small terminals of the shunt and are not reversed. Confirm a load is drawing current.
Voltage alarm flashing unexpectedlyVoltage below set threshold; Threshold set too high.Tjek den faktiske voltage of the circuit. Adjust the voltage alarm threshold to an appropriate level (refer to Operating Instructions).
Energy (Wh) reading is incorrect or not accumulatingIncorrect wiring for energy accumulation; Meter reset.Review wiring, especially for solar applications (refer to Solar System Wiring Instructions). Ensure the energy value was not accidentally reset.
Baggrundslys virker ikkeBacklight turned off; Internal fault.Press the button briefly to toggle the backlight. If it still doesn't work, contact support.

8. Vedligeholdelse

  • Rensning: Use a soft, dry cloth to clean the meter's display and casing. Brug ikke slibende rengøringsmidler eller opløsningsmidler.
  • Opbevaring: When not in use for extended periods, store the meter in a cool, dry place away from direct sunlight and extreme temperatures.
  • Inspektion: Periodically inspect the wiring and connections for any signs of wear, corrosion, or damage. Ensure all connections remain secure.

9. Garanti og support

KETOTEK products are designed for reliability and performance. For warranty information or technical support, please refer to the contact details provided with your purchase or visit the official KETOTEK website. Please have your model number (KT-D138) and purchase details ready when contacting support.

Relaterede dokumenter - KT-D138

Preview Ketotek D52-2047HD DIN-skinne multifunktionsmåler brugervejledning
Brugervejledning til Ketotek D52-2047HD DIN-skinne multifunktionsmåler med detaljerede tekniske specifikationer, anvendelsesmetoder og opmærksomhedspunkter til måling af AC-volumen.tage, strøm, aktiv effekt, frekvens og elektrisk energi.
Preview Ketotek KT-3 bærbar pH-måler brugermanual og specifikationer
Omfattende guide til Ketotek KT-3 bærbare pH-måler med detaljerede oplysninger om funktioner, specifikationer, trinvise brugsanvisninger, kalibreringsprocedurer, vedligeholdelse og garantioplysninger for nøjagtig pH-måling.
Preview KETOTEK KTEM07 Enfaset Energimåler Brugsanvisning
Omfattende brugsanvisning til KETOTEK KTEM07 enfaset energimåler, der dækker parameterindstillinger, app-tilslutning, nulstillingsfunktioner og sikkerhedsoplysninger. Indeholder tekniske specifikationer og enhedsbeskrivelser.
Preview KETOTEK KTEM02/KTEM02BL Strømforbrugsmåler - Brugermanual og funktioner
Omfattende brugsanvisning til KETOTEK KTEM02 og KTEM02BL strømforbrugsmålere. Lær om funktioner, indstillinger, sikkerhed og specifikationer.
Preview KETOTEK KT1210W-C Temperaturregulator Brugermanual
Betjeningsmanual til KETOTEK KT1210W-C temperaturregulatoren, med detaljerede specifikationer, ledningsdiagrammer og betjeningsvejledninger til forskellige anvendelser som f.eks. husholdningsfrysere, vandtanke og køleskabe.
Preview KETOTEK KT100 Fahrenheit Temperatur- og fugtighedsregulator Brugsanvisning
Omfattende betjeningsvejledning til KETOTEK KT100 Fahrenheit temperatur- og fugtighedsregulator, med detaljerede specifikationer, ledningsføring, betjeningsinstruktioner og kalibreringsprocedurer for temperatur- og fugtighedsstyring.