1. Introduktion og overview
This manual provides comprehensive instructions for the installation, operation, and maintenance of the POOLEX PC-SLP150 Silverline 150 Pool Heat Pump. Designed for pools up to 75 m3, this heat pump features a high-performance Mitsubishi compressor and a titanium exchanger for efficient and silent pool heating.
Nøglefunktioner omfatter:
- High-performance Mitsubishi compressor.
- Double-spiral titanium exchanger and twisted tech titanium coil for rapid heating.
- Durable metallic casing with anti-UV and anti-corrosion properties.
- Automatic thermostatic control.
- Compatibility with salt treatment systems.
- User-friendly LCD control panel with Touch & Go technology (optional Wi-Fi module available).

Image 1: POOLEX PC-SLP150 Silverline 150 Pool Heat Pump. This image shows the compact, grey-colored heat pump unit with a circular fan grille on the side and the "POOLEX Silverline" logo prominently displayed.
2. Sikkerhedsoplysninger
Please read all safety instructions carefully before installing, operating, or performing maintenance on the heat pump. Failure to follow these instructions may result in property damage, serious injury, or death.
- Elektrisk sikkerhed: Ensure the unit is properly grounded. All electrical connections must be performed by a qualified electrician in accordance with local and national electrical codes. Disconnect power before any service or maintenance.
- Vandsikkerhed: Do not operate the heat pump if there is a risk of freezing water inside the unit. Ensure proper water flow through the unit.
- Installation: Install the unit on a stable, level surface. Maintain adequate clearance around the unit for proper airflow and ventilation. Keep children and pets away from the unit during operation.
- Opretholdelse: Only use manufacturer-approved replacement parts. Do not attempt to modify the unit.
- Kemikalier: Avoid direct contact of pool chemicals with the heat pump casing.
3. Pakkens indhold
Before proceeding with installation, please verify that all the following components are included in your package:
- POOLEX PC-SLP150 Silverline 150 Heat Pump Unit
- Anti-vibration support kit
- PVC connectors Ø 50mm 1½''
- Kondensafløbsslange
- Vedligeholdelsessæt
- Wired control extension (10m)
- Multi-language user manual (this document)
4. Opsætning og installation
Proper installation is crucial for the efficient and safe operation of your heat pump. It is highly recommended that installation be performed by a qualified professional.
4.1. Placering
- Choose a location with good airflow, away from walls or other obstructions.
- Ensure the unit is placed on a solid, level surface capable of supporting its weight (54 kg).
- Install the anti-vibration supports to minimize operational noise and vibration.
- Position the unit to allow for easy access for maintenance.
4.2. VVS-tilslutninger
- Connect the heat pump to your pool's filtration system using the provided PVC connectors (Ø 50mm 1½'').
- Sørg for, at alle forbindelser er vandtætte for at forhindre lækager.
- Install the condensate drain hose to direct condensed water away from the unit's base.
4.3. Elektriske forbindelser
- All electrical wiring must comply with local regulations and be carried out by a certified electrician.
- Sørg for, at strømforsyningen stemmer overens med varmepumpens specifikationer.
- Connect the wired control extension (10m) if remote control panel placement is desired.
4.4. Indledende opstart
- Before powering on, ensure the pool pump is running and water is flowing through the heat pump.
- Turn on the electrical supply to the heat pump.
- Follow the operating instructions to set your desired pool temperature.
5. Betjeningsvejledning
The POOLEX PC-SLP150 Silverline 150 is designed for user-friendly operation via its LCD control panel.
5.1. Tænd/sluk
- To power on, ensure the main power supply is connected and press the power button on the LCD control panel.
- Tryk på tænd/sluk-knappen igen for at slukke.
5.2. Indstilling af temperatur
- Use the "Touch & Go" interface on the LCD panel to navigate menus.
- Select the temperature setting option and adjust to your desired pool water temperature.
- The unit will automatically begin heating until the set temperature is reached.
5.3. Driftstilstande
The heat pump primarily operates in heating mode. It will automatically regulate its operation to maintain the set temperature efficiently.
5.4. Wi-Fi Module (Optional)
An optional Wi-Fi module can be integrated for remote control and monitoring. Refer to the separate instructions provided with the Wi-Fi module for setup and operation.
6. Vedligeholdelse
Regular maintenance ensures the longevity and optimal performance of your POOLEX heat pump.
6.1. Rutinemæssig rengøring
- Keep the exterior of the unit clean, wiping it with a soft, damp klæde.
- Ensure the air intake and outlet grilles are free from leaves, debris, and other obstructions. Blocked airflow can reduce efficiency.
6.2. Kondensatafløb
- Periodically check the condensate drain hose to ensure it is not blocked and water can flow freely.
6.3. Vinterklargøring
Before the winter season or when temperatures are expected to drop below freezing, perform the following steps:
- Turn off the heat pump and disconnect its electrical supply.
- Drain all water from the heat pump and associated plumbing to prevent freezing damage.
- Cover the unit with a protective, breathable cover designed for outdoor appliances.
6.4. Maintenance Kit
Utilize the included maintenance kit for any specific cleaning or care instructions provided by POOLEX.
7. Fejlfinding
Dette afsnit omhandler almindelige problemer, du kan støde på. Hvis der er problemer, der ikke er nævnt her, eller hvis løsningerne ikke løser problemet, skal du kontakte kvalificeret servicepersonale.
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Heat pump does not turn on. | No power supply; circuit breaker tripped; unit switch off. | Check power connections; reset circuit breaker; ensure unit is switched on at the control panel. |
| Pool water is not heating. | Incorrect temperature setting; insufficient water flow; air blockage; low ambient temperature. | Verify temperature setting; ensure pool pump is running and filters are clean; check for obstructions around the unit; heat pump efficiency decreases in very cold weather. |
| Usædvanlig støj under drift. | Loose components; fan obstruction; unit not level; anti-vibration supports not installed correctly. | Inspect for loose parts; clear any fan obstructions; ensure unit is on a level surface; verify anti-vibration supports are properly installed. If noise persists, contact service. |
| Error code on LCD display. | Intern fejl; sensorproblem. | Note the error code and consult the full technical manual or contact customer support. |
8. Specifikationer
| Modelnummer | PC-SLP150 |
| Mærke | POOLEX |
| Dimensioner (L x B x H) | 92.7 x 34 x 63.6 cm |
| Vægt | 54 kg |
| Varmekapacitet | 15 kW |
| Anbefalet poolvolumen | Op til 75 m3 |
| Kompressor type | Mitsubishi High-Performance |
| Varmeveksler | Double-spiral titanium, Twisted Tech titanium coil |
| COP (26/26 conditions) | > 6 |
| Kontrolpanel | LCD with Touch & Go technology |
| Casing Materiale | Metallic, anti-UV, anti-corrosion |
9. Garanti og support
POOLEX is committed to customer satisfaction. For detailed warranty information, technical assistance, or to inquire about replacement parts, please refer to the official POOLEX webwebstedet eller kontakt din autoriserede forhandler.
You can often find additional support resources, FAQs, and contact information on the manufacturer's webwebsted.