Elitech ILD-100H

Elitech ILD-100H HVAC Kølemiddellækagedetektor Brugermanual

Model: ILD-100H | Brand: Elitech

1. Introduktion og overview

The Elitech ILD-100H is an advanced HVAC refrigerant leak detector designed for precise and efficient detection of various halogenated refrigerants. Utilizing a heated diode sensor, it offers enhanced accuracy and reliability compared to traditional sensors. This manual provides detailed instructions for the proper setup, operation, maintenance, and troubleshooting of your ILD-100H detector, ensuring optimal performance and longevity.

This device is suitable for detecting a wide range of refrigerants, including CFCs, HFCs, HCFCs, HCs, HFOs, and mixed refrigerants such as R11, R22, R404a, R410a, R600a, R1234yf, and various blends like AZ-50, HP62, and MP39. It boasts an immediate response time, making leak detection quick and effective.

2. Nøglefunktioner

  • Heated Diode Sensor: Provides superior accuracy for all halogenated refrigerants, ensuring reliable detection results.
  • TFT skærm: The innovative TFT screen offers clear and easy-to-read information, including sensitivity levels, leakage alerts, and battery status, enhancing operational clarity.
  • Høj følsomhed: Features adjustable sensitivity with High, Medium, and Low levels. The maximum sensitivity reaches up to 0.1 oz/yr, allowing for the detection of even minute leaks.
  • Hurtig betjening: Equipped with two intuitive buttons on the front panel for rapid adjustment of sensitivity and direct muting of the buzzer, simplifying user interaction.
  • Broad Refrigerant Compatibility: Capable of detecting all types of halogenated refrigerants, including HFCs (R134a, R410A, R407C, R417A, R404A, R507, R23, R508A, R508B, R152A, R32), HCFCs (R22, R123, R124, R141b, R142b, R402A, R402B, R408A, R409A), CFCs (R11, R12, R13, R502, R503), PFCs (PFC-14, PFC-116, PFC-218), and HFOs (R-1234yf), as well as HCs (R50, R170, R290, R600, R600A, R1150, R1270).
Elitech ILD-100H Halogen Leak Detector highlighting adjustable sensitivity, audible & light alarm, immediate response, and two different modes.

Figur 2.1: Overview of Elitech ILD-100H key features.

3. Produktkomponenter og dimensioner

Elitech ILD-100H with labeled components including flexible probe, UV LED, filter components, display screen, buttons, and buzzer.

Figure 3.1: Labeled components of the Elitech ILD-100H.

Elitech ILD-100H dimensions showing 7.9 inches height, 3.3 inches width, 1.5 inches depth, and a 14-inch probe length. Also lists max sensitivity, response time, battery, and compliance standards.

Figure 3.2: Physical dimensions and key performance specifications.

4. Opsætning

  1. Udpakning: Carefully remove the Elitech ILD-100H and all accessories from the packaging. Inspect for any signs of damage.
  2. Batteriopladning: The device includes a Lithium Metal battery. Before first use, ensure the battery is fully charged. Connect the appropriate charging cable (not specified in data, assume standard USB-C based on reviews) to the device and a power source. The TFT screen will indicate charging status.
  3. Sensorforberedelse: Ensure the flexible probe and filter components are securely attached. The heated diode sensor requires a brief warm-up period after powering on.
Elitech ILD-100H Refrigerant Leak Detector, a handheld device with a flexible probe and a digital display.

Figure 4.1: Elitech ILD-100H ready for setup.

5. Betjeningsvejledning

  1. Tænd: Press the 'ON/OFF' button to power on the device. The TFT screen will illuminate and display a warm-up countdown.
  2. Opvarmning: Allow the device to complete its warm-up cycle (typically 20 seconds as seen in image). This ensures the heated diode sensor reaches optimal operating temperature for accurate detection.
  3. Vælg følsomhed: Use the 'SENS' button to cycle through the sensitivity levels: High (H), Medium (M), and Low (L). Higher sensitivity is recommended for detecting smaller leaks or for initial scanning.
  4. Lækagedetektion: Slowly move the flexible probe around suspected leak areas. The device will provide visual alerts on the TFT screen (e.g., bar graph, curve display) and an audible alarm when a leak is detected. The intensity of the alarm and display will increase with higher leak concentrations.
  5. Pinpoint vs. Curve Display: The TFT screen offers two display modes. The 'Pinpoint Display' helps in finding the exact leak location, while the 'Curve Display' assists in quickly identifying the general leak area.
  6. Mute Buzzer: Press the 'MUTE' button to silence the audible alarm if needed.
  7. Sluk: Press and hold the 'ON/OFF' button to power off the device after use.
Elitech ILD-100H display modes showing Pinpoint Display for exact leak location and Curve Display for general leak area.

Figure 5.1: Understanding the Pinpoint and Curve Display modes for leak identification.

Elitech ILD-100H detecting various halogenated refrigerants including HFC, HCFC, CFC, PFC, HFO, and HC types.

Figure 5.2: The ILD-100H's capability to detect a wide range of halogenated refrigerants.

Video 5.1: En overview of Elitech's AI HVAC/R tools, demonstrating the advanced capabilities and applications of their products, including the ILD-100H leak detector in action.

6. Vedligeholdelse

  • Rensning: Tør regelmæssigt enhedens yderside af med en blød, tør klud. Brug ikke slibende rengøringsmidler eller opløsningsmidler.
  • Sensor and Filter Maintenance: The device features filter components (as shown in Figure 3.1). Refer to the full user manual (PDF link provided in product data) for specific instructions on cleaning or replacing the sensor and filter to maintain optimal performance.
  • Opbevaring: Opbevar detektoren et køligt, tørt sted væk fra direkte sollys og ekstreme temperaturer, når den ikke er i brug.

7. Fejlfinding

If you encounter issues with your Elitech ILD-100H, consider the following common troubleshooting steps:

  • Enheden tænder ikke: Ensure the battery is fully charged. If the issue persists, try connecting the charger to confirm power supply.
  • Inaccurate Readings/No Detection: Check the sensor and filter for any obstructions or damage. Ensure the device has completed its warm-up cycle. Adjust sensitivity settings to a higher level if necessary.
  • Uregelmæssig adfærd: Ensure the device is not exposed to strong electromagnetic interference. Try restarting the device.

For persistent issues or complex problems, please refer to the comprehensive user manual or contact Elitech customer support.

8. Specifikationer

AttributDetalje
MærkeElitech
ModelnummerILD-100H
StilHeated Diode Sensor
StrømkildeBatteridrevet
FarveHeated Diode Sensor Ild-100h
Produktmål (D x B x H)1.5 cm x 3.3 cm x 7.9 cm
Varens vægt2.46 pund
AlarmtypeHørbar
Driftsfugtighed85 procent
Øverste temperaturvurdering20 grader Celsius
SensortypeIR
MaterialePlast
Max følsomhed0.1 oz/år
SvartidImmediate (within 1s)
BatteritypeLitium-ion (1 litiummetalbatteri medfølger)
Batterikapacitet3.7V 3000mAh
BrugHVAC systems, refrigerant leak detection
OverholdelsesstandarderEN14624.5AE-162, SAE-2791, SAE-2913, CE
UPC704529988930, 704529989043

9. Garanti og support

The Elitech ILD-100H Refrigerant Leak Detector comes with a 1 års garanti fra købsdatoen.

For any technical assistance, product inquiries, or warranty claims, Elitech offers 7x24 customer services. Please refer to the official Elitech webwebstedet eller den fulde brugermanual for kontaktoplysninger.

You can also download the complete user manual in PDF format for more detailed information: Download brugermanual (PDF)

Relaterede dokumenter - ILD-100H

Preview Elitech WJL-6000S Corona Detector Brugervejledning
Brugermanual til Elitech WJL-6000S Corona Detektor, der indeholder detaljerede instruktioner om betjening, detektion, fejlfinding og vedligeholdelse af kølemiddellækagedetektering i forskellige systemer.
Preview Elitech ILD Series Infrarød Kølemiddellækagedetektor Brugervejledning
Omfattende brugermanual til Elitech ILD-seriens infrarøde kølemiddellækagedetektorer (ILD-100, ILD-200, ILD-300), der dækker specifikationer, betjening, vedligeholdelse og funktioner. Lær, hvordan du effektivt detekterer kølemiddellækager med denne avancerede enhed.
Preview Elitech ILD-100/ILD-200/ILD-300 Infrarød Lækagedetektor Brugermanual
Brugermanual til Elitech ILD-serien af ​​infrarøde kølemiddellækagedetektorer (ILD-100, ILD-200, ILD-300). Indeholder detaljerede oplysninger om betjening, specifikationer, funktioner og vedligeholdelse for præcis detektering af kølemiddellækage.
Preview Elitech LD-100 Opvarmet Diode Kølemiddel Lækagedetektor Brugermanual
Brugermanual til Elitech LD-100 lækagedetektor til kølemiddel med opvarmet diode, med detaljer om dens funktioner, betjening og vedligeholdelse.
Preview Elitech IR-200 Infrarød & Opvarmet Diode Lækagedetektor Brugermanual
Omfattende brugermanual til Elitech IR-200, en lækagedetektor med to sensorer, infrarød og opvarmet diodeteknologi. Lær om dens specifikationer, betjening, vedligeholdelse og funktioner til detektering af kølemiddellækager.
Preview Elitech MS-100 digital manifold: Brugermanual og specifikationer
Omfattende guide til Elitech MS-100 digital manifold, der dækker dens funktioner, tekniske specifikationer, betjening, sikkerhedsinstruktioner og fejlfinding. Lær, hvordan du bruger enheden til tryk- og temperaturmålinger, lækagetest, vakuumprocesser og datalogning med Elitech Tools-appen.