Red Lion RL-SPRK200

Red Lion RL-SPRK200 Sprinkler/Irrigation Pump Instruction Manual

Model: RL-SPRK200 (97102001)

Indledning

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Red Lion RL-SPRK200 Sprinkler/Irrigation Pump. The RL-SPRK200 is a 2 HP, 230 Volt pump designed for both residential and commercial lawn and turf sprinkling systems. It features a rugged cast iron casing and a high-efficiency thermoplastic impeller and diffuser.

The pump is engineered for easy priming up to 25 feet, requiring no additional priming after the initial fill. It delivers up to 76 GPM at 10 PSI and 64 GPM at 30 PSI, capable of handling up to 21 sprinkler heads with 1/2-inch fittings or 10 sprinkler heads with 3/4-inch fittings in each zone.

Red Lion RL-SPRK200 pump with its thermoplastic impeller shown separately

Image: The Red Lion RL-SPRK200 pump with its thermoplastic impeller, highlighting the internal component.

Sikkerhedsoplysninger

Vigtige sikkerhedsinstruktioner: Read all instructions carefully before installation and operation. Failure to follow these instructions can result in serious injury or property damage.

  • Elektrisk fare: This pump operates on 230 Volts only. It is not designed for 115 Volts and does not come with a power cord. The pump must be wired into a 230 Volt power source by a qualified electrician in accordance with all local electrical codes. Ensure the power supply is disconnected before performing any installation or maintenance.
  • Jording: Always ensure the pump is properly grounded to prevent electrical shock.
  • Bevægelige dele: Hold hænder og tøj væk fra bevægelige dele under drift.
  • Varme overflader: The pump motor can become hot during operation. Avoid contact to prevent burns.
  • Vandtryk: Always relieve system pressure before servicing the pump or plumbing.
  • Forslag 65 Advarsel: Dette produkt kan indeholde kemikalier, som staten Californien kender til at forårsage kræft og fosterskader eller anden reproduktionsskade.

Pakkens indhold

Kontroller, at alle komponenter er til stede ved udpakning:

  • Red Lion RL-SPRK200 Sprinkler/Irrigation Pump with Thermoplastic Impeller
  • Installationsvejledning (dette dokument)

Opsætning

Proper setup is crucial for optimal performance and longevity of your pump.

1. Placering

  • Install the pump on a firm, level surface to minimize vibration and ensure stable operation.
  • Locate the pump in a dry, well-ventilated area, protected from freezing temperatures and direct exposure to the elements.
  • Ensure adequate space around the pump for ventilation and future maintenance.

2. VVS-tilslutninger

The pump features a 2-inch Female NPT threaded intake and a 1.5-inch Female NPT threaded discharge.

  • Use appropriate pipe fittings and thread sealant to ensure watertight connections.
  • Install a foot valve or check valve on the intake line to maintain prime.
  • Ensure all plumbing is adequately supported to prevent strain on the pump housing.
Diagram showing the Red Lion RL-SPRK200 pump with labels for 2 inch FNPT intake, 1.5 inch FNPT discharge, capacitor start, thermally protected motor, and cast iron casing.

Image: Key features of the RL-SPRK200 pump, including intake and discharge ports.

3. Elektrisk tilslutning

This pump requires a dedicated 230 Volt power source.

  • Electrical wiring must be performed by a qualified electrician.
  • Connect the pump to a 230 Volt, 10.9 running Amps kredsløb.
  • The motor is a Capacitor-run PSC design and is thermally protected.
  • Sørg for, at al ledningsføring overholder nationale og lokale elektriske forskrifter.

4. Priming af pumpen

The RL-SPRK200 is designed for one-time priming. No additional priming is required after the initial fill, provided the intake line and foot valve hold prime.

  1. Fjern spædeproppen, der er placeret øverst på pumpen c.asing.
  2. Fyld pumpen casing completely with water until it overflows from the priming hole.
  3. Sæt spædeproppen sikkert på igen.
  4. Åbn alle udløbsventiler for at tillade luft at slippe ud af systemet.
  5. Turn on the power to the pump. The pump should begin to draw water and build pressure.
  6. Allow the pump to run until a steady stream of water flows from the discharge.
  7. If the pump does not prime within 5 minutes, turn it off, recheck all connections for leaks, and repeat the priming process.
Red Lion RL-SPRK200 pump operating in a lawn with sprinklers in the background.

Image: The RL-SPRK200 pump installed and operating, providing water for a sprinkler system.

Betjeningsvejledning

Once the pump is properly installed and primed, operation is straightforward.

  • Ensure all intake and discharge valves are open before starting the pump.
  • Turn on the electrical power to the pump. The pump will start and begin to build pressure.
  • Monitor the system for proper water flow and pressure. The pump can deliver up to 76 GPM at 10 PSI and 64 GPM at 30 PSI.
  • If the pump runs continuously without building pressure, refer to the troubleshooting section.
  • To stop the pump, turn off the electrical power.
Close-up of a sprinkler head watering a lawn, with the Red Lion pump visible in the foreground.

Image: A sprinkler head in operation, demonstrating the pump's function in an irrigation system.

Opretholdelse

Regular maintenance ensures reliable performance and extends the life of your pump.

  • Regelmæssig inspektion: Periodically inspect the pump and plumbing for leaks, corrosion, or damage. Tighten any loose connections.
  • Renhed: Keep the pump area clean and free of debris to ensure proper motor ventilation.
  • Vinterisering: In areas subject to freezing temperatures, the pump must be drained completely to prevent damage. Disconnect power, remove drain plugs, and allow all water to escape. Store the pump in a warm, dry location if possible.
  • Impeller Check: If performance degrades, inspect the thermoplastic impeller for wear or obstructions.

Fejlfinding

This section addresses common issues you might encounter with your Red Lion RL-SPRK200 pump.

ProblemMulig årsagLøsning
Pumpen starter ikkeNo power; tripped circuit breaker; faulty wiring.Check power supply; reset breaker; verify 230V connection.
Pumpen kører, men intet vand eller lavt flowLoss of prime; air leak in suction line; clogged intake; low water source.Re-prime the pump; check all suction line connections for leaks; clear intake; ensure adequate water supply.
Pump not performing to specificationsForkert voltage (e.g., connected to 115V); worn impeller; motor issue.Ensure pump is connected to a 230 Volt power source. Inspect impeller; contact support if motor issue is suspected.
Overdreven støj eller vibrationerLoose mounting; cavitation (air in pump); foreign object in impeller.Tighten mounting bolts; check for air leaks in suction line; inspect impeller for obstructions.

For more detailed troubleshooting, consult the full owner's manual or contact technical support.

Specifikationer

Technical specifications for the Red Lion RL-SPRK200 Sprinkler/Irrigation Pump:

  • Model: RL-SPRK200 (97102001)
  • Hestekræfter (HK): 2.0 HK
  • Voltage: 230 volt
  • Løb Amps: 10.9 Amps @ 230V
  • Wattage: 7332 watt
  • Maksimal gennemstrømningshastighed: 76 gallon pr. minut (GPM)
  • Maksimalt tryk: 49 PSI
  • Maximum Lifting Height (Suction Lift): 25 fod
  • Indsugningsforbindelse: 2-inch Female NPT threaded
  • Afladningsforbindelse: 1.5-inch Female NPT threaded
  • Materiale: Cast Iron casing, Thermoplastic impeller
  • Produktmål (L x B x H): 21.85 cm x 11.42 cm x 10.2 cm
  • Varens vægt: 63 pund
  • Motortype: Capacitor-run PSC design, Thermally protected
  • Certificeringer: CSA listed (US and Canada)
Technical diagram showing the dimensions of the SPRK series sprinkler pumps, with height A at 10.2 inches, length B at 21.85 inches, and width C at 11.42 inches.

Image: Dimensional drawing of the SPRK series pumps, including the RL-SPRK200.

Performance chart for Centrifugal Sprinkler Pumps, showing Total Dynamic Head (ft) versus Capacity (US gpm) for various RL-SPRK models, including RL-SPRK200.

Image: Performance curve chart illustrating the flow and head characteristics of the RL-SPRK200 and other models.

Garanti

The Red Lion RL-SPRK200 Sprinkler/Irrigation Pump is covered by a 2 års producentgarantiGem venligst din købsbevis i tilfælde af garantikrav. For specifikke vilkår og betingelser henvises til garantidokumentationen, der følger med dit produkt, eller kontakt Red Lions kundesupport.

Støtte

For technical assistance, troubleshooting, or installation support, please contact Red Lion customer service.

  • Teknisk support telefon: 1-888-885-9254
  • You may also visit the official Red Lion webwebsted for yderligere ressourcer og ofte stillede spørgsmål.
Red Lion 'About Us' image featuring people and the brand logo, with technical support contact information.

Image: Red Lion 'About Us' section, including technical support contact details.

Relaterede dokumenter - RL-SPRK200

Preview Red Lion RL-SPRK-seriens sprinklerpumpe brugermanual - installations-, drifts- og vedligeholdelsesvejledning
Denne manual indeholder omfattende instruktioner til Red Lion RL-SPRK-serien af ​​sprinklerpumper, der dækker installation, mængdetagIndstillinger, betjening, vedligeholdelse, fejlfinding og reservedele. Designet til sprinkleranlæg til græsplæner og -tørv i private hjem og erhvervsejendomme.
Preview Red Lion RLHE-300 støbejerns industriel sprinklerpumpe brugermanual
Omfattende brugermanual til Red Lion RLHE-300 industrisprinklerpumpen, der dækker installation, betjening, vedligeholdelse og fejlfinding. Funktionerne inkluderer kraftig jernbelægning.asing, højeffektivt løbehjul og automatisk termisk beskyttelse.
Preview Red Lion 4-inch Deep Well Submersible Pump Manual
Comprehensive guide for Red Lion 4-inch deep well submersible pumps, covering installation, electrical connections, maintenance, and troubleshooting for RL and RS series models.
Preview Fejlfindingsvejledning til Red Lion-pumper: Løsninger til jet-, dyk- og transferpumper
Omfattende fejlfindingsvejledning til Red Lion vandpumper, herunder lavvandede brøndspumper (f.eks. RJS-50-PREM), konvertible jetpumper (f.eks. RJC-50), 4" dykpumper til brønd (f.eks. RL12G10-3W2V), dykpumper til forsynings- og sumpanlæg, RL-S støbejerns-overfladespildevandspumper, RL-50 overførselspumper og RLSP/RLHE sprinklerpumper. Find løsninger på almindelige problemer som motorfejl, problemer med priming, lavt tryk og mere.
Preview Red Lion RJSE-75SS Sprinklerpumpe - Betjenings- og vedligeholdelsesmanual
Omfattende vejledning til Red Lion RJSE-75SS sprinklerpumpe, der dækker sikkerhedsadvarsler, elektriske forholdsregler, anvendelse, installation, drift, vedligeholdelse og fejlfinding. Indeholder detaljerede diagrammer og garantioplysninger.
Preview Red Lion 4-tommer dykpumpe til dyb brønd, brugermanual og installationsvejledning
Omfattende vejledning til Red Lion 4-tommer dykpumper til dybe brønde (RL-serien og RS-serien), der dækker specifikationer, sikkerhed, installation, vedligeholdelse og fejlfinding til vandforsyning i landdistrikter. Indeholder modeloplysninger, elektriske krav og driftsrådgivning.