1. Introduktion
The CONTEC ABPM50 is an automatic 24-hour blood pressure monitor designed for continuous, non-invasive blood pressure (NIBP) monitoring. This device provides accurate and reliable measurements, allowing for comprehensive tracking of blood pressure trends over extended periods. Its compact and portable design, combined with a user-friendly interface, makes it suitable for both clinical and home use.
Nøglefunktioner:
- 24-Hour NIBP Monitoring: Capable of recording up to 350 groups of NIBP data over a 24-hour period, providing a full day and night's blood pressure profile.
- Configurable Measurement Intervals: Automatic measurement intervals can be set to 5, 10, 15, 20, 30, 40, 60, 90, 120, 180, or 240 minutes.
- Alarmfunktionalitet: Allows setting of blood pressure thresholds with an alarm to notify if readings fall outside the set range.
- Easy Setup and Data Transfer: Supports both automatic and manual measurement methods, with up to 300 groups of data recordable manually. Data can be reviewed via 'data list', 'trend graph', and 'big font' interfaces.
- Bærbart design: Compact and lightweight for convenient use and transport.
- Farvedisplay med høj opløsning: Giver klare og letlæselige måleresultater.
2. Vigtige sikkerhedsoplysninger
Please read all instructions carefully before using the CONTEC ABPM50 monitor. Failure to follow these guidelines may result in inaccurate readings or device malfunction.
- This device is intended for non-invasive blood pressure measurement in adults.
- Do not use this device on infants or individuals who cannot communicate their discomfort.
- Consult with a healthcare professional for interpretation of blood pressure readings and before making any medical decisions.
- Forsøg ikke at reparere eller ændre enheden. Overlad al service til kvalificeret personale.
- Opbevar enheden og dens komponenter utilgængeligt for børn og kæledyr.
- Undgå at udsætte enheden for ekstreme temperaturer, fugt eller direkte sollys.
- Udtalelser vedrørende kosttilskud er ikke blevet evalueret af FDA og er ikke beregnet til at diagnosticere, behandle, helbrede eller forebygge nogen sygdom eller sundhedstilstand.
3. Pakkens indhold
Ved udpakning skal du kontrollere, at alle følgende komponenter er inkluderet:
- CONTEC ABPM50 Blood Pressure Monitor Unit
- Adult Cuff (Size: 9.84"-13.78" / 25cm-35cm)
- Bæretaske
- BP Extending Tube
- USB-datalinje
- Brugermanual

Figur 3.1: Forside view of the CONTEC ABPM50 Blood Pressure Monitor, displaying a blood pressure reading of 120/80 mmHg and a pulse rate of 80 bpm.

Figure 3.2: Infographic highlighting key features of the CONTEC ABPM50, including blood pressure measurement, low power prompt, display trend graph, 350 groups memory storage, software for 24-hour NIBP Holter, high-definition color display, small and portable design, and one-key measurement.

Figure 3.3: All included components of the CONTEC ABPM50 system: the main monitor unit, an adult cuff, a BP extending tube, an USB data line, and a carrying pouch.
4. Setup and Cuff Placement
4.1 Batteriinstallation
The CONTEC ABPM50 is powered by batteries. Open the battery compartment, typically located on the back or side of the device, and insert the required batteries, ensuring correct polarity. Close the compartment securely.
4.2 Connecting the Cuff and Tube
Connect the BP extending tube to the monitor unit's air tube connector. Then, connect the other end of the extending tube to the adult cuff's air tube connector. Ensure all connections are secure to prevent air leakage during measurement.
4.3 Korrekt manchetplacering
Accurate blood pressure readings depend significantly on correct cuff placement. The cuff should be placed on the upper arm, directly on the skin, approximately 1-2 cm above the elbow joint. The artery mark on the cuff should align with the brachial artery on the inside of your arm.

Figure 4.1: Illustration of proper cuff placement on the upper arm, with the monitor unit connected via the extending tube. The cuff should be at the same level as the patient's heart for accurate readings.
Important Note on Cuff Level: The cuff should be placed at the same level as the patient's heart. If the cuff is placed higher or lower than the heart level, the measurement results may need adjustment:
- If the cuff is placed higher than the heart level, add 0.75 mmHg (0.10 kPa) for each inch of difference.
- If it is placed lower than the heart level, subtract 0.75 mmHg (0.10 kPa) for each inch of difference.

Figure 4.2: Table detailing various cuff sizes for adult, baby, and child, including limbs circumference, cuff width, and length of inflation tube for both reusable and disposable cuffs. The included adult cuff is suitable for limb circumferences of 25-35 cm.
5. Betjeningsvejledning
5.1 Tænd/sluk
Press the power button (usually marked with a power symbol) to turn the device on. To turn off, press and hold the power button until the display shuts down.
5.2 Manuel måling
To take a single, immediate blood pressure reading:
- Ensure the cuff is correctly placed on your arm.
- Press the 'RUN' or 'OK' button (refer to device buttons). The cuff will begin to inflate automatically.
- Forbliv stille og stille under målingen.
- Once the measurement is complete, the results (Systolic, Diastolic, and Pulse Rate) will be displayed on the screen.
5.3 24-Hour Ambulatory NIBP Monitoring
The primary function of the ABPM50 is continuous 24-hour monitoring. This mode allows for automatic measurements at predefined intervals throughout the day and night.
- Adgangsmenu: Press the 'MENU' button to navigate through the device settings.
- Select ABPM Option: Locate and select the 'ABPM' or '24hr Monitoring' option.
- Set Intervals: Choose your desired automatic measurement intervals from the available options (e.g., 5, 10, 15, 20, 30, 40, 60, 90, 120, 180, 240 minutes).
- Start overvågning: Set the 'On/Off' option to 'Begin' and confirm with the 'OK' button. The device will prompt you to choose whether to delete previous data or add to it. Select the appropriate option.
- Wear the Device: Secure the monitor unit in the carrying pouch and wear it comfortably, ensuring the cuff remains properly positioned.

Figure 5.1: The CONTEC ABPM50 monitor unit shown next to a person sleeping, illustrating its 24-hour ambulatory NIBP monitoring capability for continuous health protection.
5.4 Indstilling af alarmer
The device allows you to set high and low blood pressure thresholds. If a measurement falls outside these limits, an alarm can be triggered.
- Navigate to the 'Alarm Settings' in the menu.
- Adjust the systolic and diastolic upper and lower limits as needed.
- Aktiver alarmfunktionen.
5.5 Vedrviewing data
The ABPM50 stores measurement data for later review. You can access stored data through various display modes:
- Dataliste: Displays individual measurement records in a list format.
- Trend Graph: Visualizes blood pressure trends over time.
- Big Font: Shows current or selected data in a larger font for easier readability.
Use the navigation buttons (up/down, left/right, OK) to browse through the stored data.
6. Data Management and PC Software
The CONTEC ABPM50 allows for data transfer to a personal computer for more detailed analysis and record-keeping. This feature is crucial for sharing comprehensive blood pressure profiles with healthcare providers.
- Tilslutning til pc: Use the provided USB data line to connect the monitor unit to your computer.
- Software installation: The device requires specific PC software for data transfer and analysis. Please refer to the instructions provided with the device for software download and installation. Note that a physical CD may not be included; download instructions are typically found on the product packaging or within the user manual.
- Dataanalyse: Softwaren giver dig mulighed for at view detailed reports, trend graphs, and statistical analysis of your blood pressure readings, which can be printed or exported.
7. Vedligeholdelse og opbevaring
7.1 Rengøring
- Wipe the monitor unit with a soft, dry cloth. If necessary, use a cloth lightly damprengøres med vand eller et mildt desinfektionsmiddel. Brug ikke slibende rengøringsmidler, og enheden må ikke nedsænkes i vand.
- Rengør manchetten regelmæssigt med adamp cloth and mild soap. Allow it to air dry completely before storage or next use.
7.2 Opbevaring
- Store the device and its components in the provided carrying pouch when not in use.
- Opbevares køligt og tørt, væk fra direkte sollys, ekstreme temperaturer og høj luftfugtighed.
- Fjern batterierne, hvis enheden ikke skal bruges i længere tid, for at forhindre lækage.
8. Fejlfinding
If you encounter issues with your CONTEC ABPM50, please refer to the following common solutions. If the problem persists, contact customer support.
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Enheden tænder ikke. | Lave eller døde batterier; forkert batteriinstallation. | Udskift batterierne med nye; sørg for korrekt polaritet. |
| Manchetten pustes ikke op eller pustes ikke korrekt op. | Air tube disconnected; cuff not properly wrapped; air leakage. | Check all tube connections; re-wrap cuff snugly; inspect cuff and tube for damage. |
| Unøjagtige eller inkonsistente aflæsninger. | Improper cuff placement; movement during measurement; talking during measurement. | Ensure cuff is correctly placed at heart level; remain still and silent during measurement. |
| Dataoverførsel til pc mislykkes. | USB cable not connected properly; software not installed or outdated; driver issues. | Ensure USB cable is secure; install or update PC software and drivers as per instructions. |
9. Tekniske specifikationer
| Feature | Specifikation |
|---|---|
| Modelnavn | ABPM50 |
| Produktdimensioner | 12.8 cm x 3.6 cm x 6.9 cm (L x B x T) |
| Vægt | 1.81 pund (ca. 0.82 kg) |
| Strømkilde | Batteridrevet |
| Display Type | LCD |
| Cuff Size (Adult) | 9.84"-13.78" (25cm-35cm) |
| Aldersinterval | Voksen |
| 24hr NIBP Data Storage | Op til 350 grupper |
| Manual NIBP Data Storage | Op til 300 grupper |
| Automatic Measure Interval Options | 5, 10, 15, 20, 30, 40, 60, 90, 120, 180, 240 minutes |
| Inkluderede komponenter | Monitor, Adult Cuff, Carrying Pouch, BP Extending Tube, USB Cable |
10. Garanti og support
10.1 Garantioplysninger
The CONTEC ABPM50 Blood Pressure Monitor comes with a et års garanti from the date of purchase. This warranty covers manufacturing defects and malfunctions under normal use. It does not cover damage caused by misuse, accidents, unauthorized repairs, or failure to follow the instructions in this manual.
10.2 Kundesupport
For any concerns regarding your device, technical assistance, warranty claims, or questions not covered in this manual, please contact CONTEC customer support. Refer to the contact information provided on the product packaging or the official CONTEC webwebsted.