Produkt overview
The Utilitech 50AC-110 Water Transfer Pump is designed for efficient liquid transfer. This pump is ideal for draining water heaters, water beds, washing machines, or for filling radiant heating systems. It comes complete with a 6 ft. suction hose, suction attachment, and extra impeller and gasket for convenience.

Figure 1: Utilitech 50AC-110 Water Transfer Pump, a compact black pump with silver fittings and a carrying handle.
Opsætning og udpakning
Upon unboxing, ensure all components are present: the pump unit, a 6-foot suction hose, a suction attachment for flat surfaces or submerged use, an extra impeller, and a gasket. The pump is designed for 115V operation and features a clear flow indicator for correct hose connection.
No official seller videos are available for unboxing or setup. Please refer to the text instructions and diagrams.
Betjeningsvejledning
Sikkerhedsforanstaltninger:
- Always ensure power to the water heater is turned off before draining to prevent damage to heating elements.
- Turn off the main water supply to the house before beginning any draining procedure.
- Never run the pump dry. Ensure water is flowing through the pump before activating it.
- Pump ikke brændbare væsker.
Draining a Water Heater:
- Turn off Power and Water Supply: Locate and turn off the circuit breaker for the water heater. Also, turn off the main water supply to your house.
- Open Relief Valve: Open the temperature and pressure relief valve on the water heater to allow air into the tank, facilitating drainage.
- Tilslut slanger:
- Connect one end of a suitable hose (e.g., a washing machine hose, as the included hose may not be compatible with all setups) to the drain valve at the bottom of the water heater.
- Connect the other end of this hose to the inlet port of the Utilitech pump. The pump has an arrow indicating the direction of water flow; ensure the hose from the water heater connects to the inlet side (opposite the arrow).
- Connect a discharge hose to the outlet port of the pump (in the direction of the arrow). Direct the discharge hose to a suitable drainage area, such as a floor drain or outdoors.
- Forbered pumpen: Before turning on the pump, slightly open the water heater drain valve to allow water to flow into the pump, ensuring it is primed and does not run dry.
- Aktiver pumpe: Once water is flowing through the pump, plug in the pump to an appropriate 115V power outlet. The pump will begin to transfer water.
- Overvåg dræning: Allow the pump to operate until the water heater is fully drained. The pump significantly speeds up the draining process compared to gravity drainage.
- Disconnect and Restore: After draining, turn off the pump, disconnect the hoses, close the water heater drain valve, close the relief valve, restore the main water supply, and finally, restore power to the water heater.
No official seller videos are available for operating instructions. Please refer to the text instructions and diagrams.
Opretholdelse
Regular maintenance ensures the longevity and optimal performance of your Utilitech Water Transfer Pump.
- Rensning: After each use, flush the pump with clean water to remove any debris or sediment.
- Opbevaring: Store the pump in a dry, cool place, protected from freezing temperatures.
- Inspektion af impeller: Periodically inspect the impeller for wear or damage. Replace if necessary using the provided extra impeller and gasket. Refer to the pump's internal diagram for replacement instructions.
- Slangeinspektion: Check hoses for cracks, leaks, or blockages before and after each use.
Fejlfinding
If you encounter issues with your Utilitech Water Transfer Pump, consider the following common solutions:
- Pumpen starter ikke:
- Ensure the pump is securely plugged into a live 115V outlet.
- Kontroller afbryderen til stikkontakten.
- Verify that the pump is not running dry. The pump is thermally protected and may shut off if overheated from running without liquid. Allow it to cool down.
- Low Flow/No Flow:
- Check for kinks or blockages in the suction or discharge hoses.
- Ensure the pump is properly primed with water before operation.
- Inspect the impeller for clogs or damage.
- Verify that the water source is sufficient and the main water supply is open if applicable.
- Lækker:
- Spænd alle slangeforbindelser.
- Inspect gaskets and O-rings for wear or improper seating. Replace if damaged.
For persistent issues, contact Utilitech customer support.
Specifikationer
| Feature | Detalje |
|---|---|
| Mærke | Utilitech |
| Model | 50AC-110 |
| Hestekræfter | 1 / 12 HP |
| Voltage | 115V |
| Flowhastighed | 5.6 GPM (Gallons pr. minut) |
| Varens vægt | 3.75 pund |
| Produktdimensioner | 8.3 x 7.5 x 8.3 tommer |
| Stil | Over Jorden |
| UPC | 850664002076 |
Garanti og support
Dette istandsatte produkt er testet og certificeret til at se ud og fungere som nyt. Istandsættelsesprocessen omfatter funktionstest, grundlæggende rengøring, inspektion og ompakning. Produktet leveres med alt relevant tilbehør og kan ankomme i en generisk æske.
For further assistance or warranty claims, please contact Utilitech customer service. Refer to the product packaging or the official Utilitech website for specific contact information and detailed warranty terms.