Red Lion PAXI0020

Red Lion Controls PAXI0020 Pax-tæller/hastighedsmåler brugermanual

Model: PAXI0020

1. Introduktion

This manual provides essential information for the safe and efficient operation, installation, and maintenance of the Red Lion Controls PAXI0020 Pax Counter/Rate Meter. Please read this manual thoroughly before installing or operating the device. Retain this manual for future reference.

2. Sikkerhedsoplysninger

ADVARSEL: Improper installation or operation can result in personal injury or damage to the equipment. Always follow local and national electrical codes.

  • Disconnect all power before installing or servicing the unit.
  • Sørg for korrekt jording for at forhindre elektrisk stød.
  • Brug ikke enheden i miljøer, der overstiger de angivne temperatur- og fugtighedsgrænser.
  • Kun kvalificeret personale bør udføre installation og vedligeholdelse.
  • Kontroller, at alle ledningsforbindelser er sikre og korrekte, før du tilslutter strømmen.

3. Produktet er slutview

The Red Lion Controls PAXI0020 is an AC-powered industrial counter and rate meter designed for precise measurement and display in various applications. It features a bright, easy-to-read display and intuitive front-panel controls for configuration and operation.

Front panel of the Red Lion Controls PAXI0020 Pax Counter/Rate Meter, showing a red digital display with the number 125005 and five control buttons labeled DSP, PAR, F1, F2, and RST.

This image displays the front face of the PAXI0020 unit. It features a large, red seven-segment LED display at the top, currently showing '125005'. Below the display are five push-buttons: 'DSP' (Display), 'PAR' (Parameter), 'F1' (Function 1), 'F2' (Function 2), and 'RST' (Reset). These buttons are used for navigating menus, adjusting settings, and controlling the meter's functions.

Komponenter på frontpanelet:

  • Vise: High-visibility red LED display for showing count, rate, and parameter values.
  • DSP knap: Used to cycle through various display modes or views.
  • PAR Button: Accesses the parameter menu for configuration and setup.
  • F1-knap: Function key 1, typically user-programmable or for specific menu navigation.
  • F2-knap: Function key 2, typically user-programmable or for specific menu navigation.
  • RST-knap: Resets the counter or clears error states.

4. Opsætning

4.1. Installation

The PAXI0020 is designed for panel mounting. Ensure adequate space for ventilation and access to wiring terminals. Cut a panel opening according to the dimensions provided in the product's technical specifications sheet (not included in this manual). Secure the unit using the provided mounting hardware.

4.2. Ledninger

FORSIGTIGHED: Sørg for, at strømmen er afbrudt, før du foretager nogen ledningstilslutninger.

  • Strømforsyning: Connect the AC power supply to the designated terminals. Refer to the product label for specific voltage krav.
  • Indgangssignaler: Connect your counting or rate input signals (e.g., from sensors, encoders) to the appropriate input terminals. Pay close attention to polarity and signal type (e.g., NPN, PNP).
  • Udgangsforbindelser: If using control outputs, connect them to your external devices (e.g., relays, PLCs) as required by your application.
  • Jording: Ensure the unit is properly grounded to a protective earth.

After all connections are made, double-check them for correctness and security before applying power.

5. Betjeningsvejledning

5.1. Tænd

Once properly wired, apply AC power to the unit. The display will illuminate, typically showing the current count or rate value.

5.2. Basic Display Modes (DSP Button)

Tryk på DSP button to cycle through available display modes. These may include:

  • Current Count Value
  • Current Rate Value
  • Peak/Min Values
  • Totalized Count

5.3. Parameter Configuration (PAR Button)

Tryk og hold på PAR button to enter the parameter setup menu. Use the F1 og F2 buttons to navigate through parameters and adjust values. The DSP button may be used to confirm selections or move to the next digit/setting. Common parameters include:

  • Input type and scaling
  • Output functions and setpoints
  • Decimalposition
  • Vis opdateringshastighed
  • Sikkerhedsindstillinger

Refer to the detailed programming guide (typically a separate document) for comprehensive parameter descriptions and configuration steps.

5.4. Resetting the Counter (RST Button)

Tryk på RST button to reset the active counter to zero. The function of the RST button may be configurable in the parameter menu (e.g., local reset, remote reset, or disabled).

6. Vedligeholdelse

The PAXI0020 is designed for minimal maintenance. Regular inspection and cleaning are recommended.

  • Rensning: Brug en blød, damp cloth to clean the front panel. Do not use abrasive cleaners or solvents.
  • Inspektion: Periodically check wiring connections for tightness and signs of wear or corrosion. Ensure the unit's ventilation is not obstructed.
  • Kalibrering: The unit is factory calibrated. If recalibration is suspected, contact Red Lion Controls support.

7. Fejlfinding

If the PAXI0020 is not functioning as expected, review følgende almindelige problemer:

  • Intet display/Ingen strøm:
    • Verify AC power supply is connected and active.
    • Check fuses (if applicable) in the power circuit.
    • Ensure wiring connections are secure.
  • Incorrect Count/Rate:
    • Check input signal wiring and sensor operation.
    • Verify input scaling and parameter settings in the PAR menu.
    • Ensure the correct input type (e.g., NPN, PNP) is selected.
  • Visningsfejl:
    • Consult the product's full technical manual for a list of error codes and their meanings.
    • Try cycling power to the unit.
  • Knapper reagerer ikke:
    • Ensure the unit is not in a locked mode (check security settings in PAR menu).
    • Sluk for strømmen til enheden.

If problems persist, contact Red Lion Controls technical support.

8. Specifikationer

SpecifikationVærdi
ModelPAXI0020
FabrikantRed Lion Controls
StrømindgangAC (Specific voltage range typically on product label)
Varens vægt22 pund
ASINB07CYPVM83
Dato først tilgængelig8. maj 2018

9. Garanti og support

Warranty information for the Red Lion Controls PAXI0020 is typically provided with the product at the time of purchase or can be obtained directly from Red Lion Controls. For technical assistance, product documentation, or warranty claims, please contact Red Lion Controls customer support.

You can also visit the official Red Lion store for more information: Red Lion Store on Amazon

Relaterede dokumenter - PAXI0020

Preview Red Lion CUB®5 Miniature Elektronisk 8-cifret Dobbelttæller og Hastighedsindikator Manual
Omfattende brugermanual til Red Lion CUB®5, der beskriver dens funktioner som en miniature elektronisk 8-cifret dobbelt tæller og hastighedsindikator, inklusive installations-, programmerings- og kommunikationsmuligheder til industrielle applikationer.
Preview Red Lion PAX-serien af ​​1/8 DIN analoge indgangspanelmålere - brugermanual
Omfattende brugermanual til Red Lion PAX-serien af ​​1/8 DIN analoge indgangspanelmålere, der dækker specifikationer, installation, ledningsføring, programmering, fejlfinding og optionskort til modellerne PAXD, PAXP, PAXS, PAXT og PAXH.
Preview Red Lion CUB5 Miniature Dual Counter and Rate Indicator User Manual
Detailed user manual and datasheet for the Red Lion CUB5 miniature electronic 8-digit dual counter and rate indicator. Learn about features, specifications, installation, programming, and serial communications.
Preview Brugermanual til Red Lion PAX-serien af ​​1/8 DIN analoge indgangspanelmålere
Brugermanual og teknisk datablad til Red Lion PAX-serien af ​​1/8 DIN analoge indgangspanelmålere (PAXD, PAXP, PAXH, PAXS, PAXT). Dækker specifikationer, installation, ledningsføring, programmering og fejlfinding inden for industriel automation.
Preview Red Lion CUB5P miniature elektronisk 5-cifret procesmåler brugermanual
Detaljeret brugermanual til Red Lion CUB5P miniature elektronisk 5-cifret procesmåler, der dækker installation, ledningsføring, programmering og specifikationer. Lær om dens funktioner, muligheder og betjening.
Preview Red Lion CUB5 miniature elektronisk 8-cifret dobbelt tæller og hastighedsindikator
Detaljerede specifikationer, installationsvejledning og programmeringsmanual til Red Lion CUB5 miniature elektronisk 8-cifret dobbelt tæller og hastighedsindikator. Funktionerne omfatter valgbar LCD- eller LED-baggrundsbelysning, valgfrie relæ- og serielle kommunikationsmoduler samt NEMA 4X/IP65-tætning.