Digitus DN-91624S-EA

Digitus Cat-6A 24-Port Shielded Patch Panel (DN-91624S-EA) Instruction Manual

Model: DN-91624S-EA

1. Introduktion

This manual provides detailed instructions for the installation, operation, and maintenance of your Digitus Cat-6A 24-Port Shielded Patch Panel, model DN-91624S-EA. This patch panel is designed for efficient cable management and reliable network connectivity in 19-inch rack environments, supporting high-speed data transmission up to 10 Gigabit Ethernet (10GBase-T) and Power over Ethernet (PoE+) applications.

2. Sikkerhedsoplysninger

3. Pakkens indhold

Bekræft at alle varer er til stede i pakken:

4. Produktet er slutview

The Digitus Cat-6A 24-Port Shielded Patch Panel features 24 RJ45 ports on the front for connecting network devices via patch cables, and LSA (LSA-Plus) termination blocks on the rear for permanent cable installation. The panel is designed for 1U rack mounting and provides robust shielding for enhanced signal integrity.

Front view of the Digitus Cat-6A 24-Port Shielded Patch Panel

Figur 4.1: Forside view of the Digitus Cat-6A 24-Port Shielded Patch Panel, showing 24 numbered RJ45 ports and the Cat.6A label.

Bag view of a patch panel showing LSA termination blocks

Figur 4.2: Bagside view of a patch panel (illustrative, white variant shown) displaying the LSA termination blocks for connecting network cables.

5. Installation

5.1. Rack montering

  1. Identify an available 1U (1.75 inches) space in your standard 19-inch network or server cabinet.
  2. Align the mounting ears of the patch panel with the rack rails.
  3. Secure the patch panel to the rack using the provided mounting screws. Ensure it is firmly attached.

5.2. Cable Termination (LSA Strips)

The patch panel uses LSA (LSA-Plus) termination blocks, color-coded according to EIA/TIA 568 A and B standards. Ensure you consistently use either standard A or standard B for all connections within your network.

Close-up of LSA termination blocks with terminated network cables

Figur 5.1: Nærbillede view of LSA termination blocks (illustrative, white variant shown) with network cables properly terminated and secured.

  1. Prepare your Cat-6A network cables by stripping approximately 1-2 inches of the outer jacket, exposing the twisted pairs. Be careful not to damage the wire insulation.
  2. Untwist the pairs minimally, just enough to separate the individual wires.
  3. Refer to the color coding diagram on the LSA block (EIA/TIA 568 A or B).
  4. Place each individual wire into its corresponding slot on the LSA block.
  5. Use an LSA punch-down tool to firmly press each wire into its slot. The tool will simultaneously cut off any excess wire.
  6. Repeat this process for all 24 ports.
  7. After termination, use the provided cable ties to secure the installed cables to the cable management bar at the rear of the patch panel, reducing strain on the LSA connections.
  8. Ensure proper grounding of the patch panel to the rack for optimal shielding.

6. Betjeningsvejledning

Once the network cables are terminated on the rear LSA blocks, the patch panel is ready for operation.

  1. Connect standard RJ45 patch cables from your network devices (e.g., computers, servers, switches) to the front RJ45 ports of the patch panel.
  2. Ensure the patch cables are fully inserted and click into place.
  3. The patch panel facilitates organized connections between your network infrastructure and end devices.
Close-up of RJ45 ports with red patch cables connected

Figur 6.1: Nærbillede view of RJ45 ports (illustrative, white variant shown) with red patch cables connected, demonstrating active network connections.

7. Vedligeholdelse

8. Fejlfinding

If you encounter issues with your network connections through the patch panel, consider the following:

ProblemMulig årsagLøsning
Ingen netværksforbindelseLoose patch cable connection
Incorrect LSA termination
Faulty patch cable
Ensure patch cables are fully seated
Verify LSA terminations using a cable tester and re-terminate if necessary
Test with a known good patch cable
Langsom netværkshastighedPoor quality patch cable
Improper Cat-6A termination
Interference (lack of proper shielding)
Use certified Cat-6A patch cables
Ensure LSA terminations follow EIA/TIA 568 A/B standards precisely
Verify patch panel and cables are properly shielded and grounded
Intermitterende forbindelseBeskadiget kabel
Loose LSA termination
Problem med forbindelsen
Efterse og udskift beskadigede kabler
Re-punch loose LSA connections
Check RJ45 ports for damage

9. Specifikationer

FeatureDetalje
ModelnummerDN-91624S-EA
TransmissionsegenskaberCategory 6A, Class EA
AnvendelsesområdeUp to 500 MHz, 10GBase-T
Norms ComplianceISO/IEC 11801 2nd Ed., EN 50173-1, EIA/TIA 568-C, 802.3af, 802.3at PoE+
Montering483 mm (19") cabinet mounting, 1U height
Kabel installationLSA strips, color coded according to EIA/TIA 568 A & B
Connector TypeRJ45
Dimensioner (L x B x H)19.02 x 4.33 x 1.77 tommer (ca.)
Vægt3.24 pund (ca.)

10. Garanti og support

Digitus products are manufactured to high-quality standards and are backed by a manufacturer's warranty. For specific warranty terms and conditions, please refer to the documentation provided with your purchase or visit the official Digitus website. For technical support or assistance, please contact your local Digitus distributor or reseller.

For further information, you may visit the Digitus webwebsted: www.digitus.info

Relaterede dokumenter - DN-91624S-EA

Preview Installationsvejledning til DIGITUS afskærmet patchpanel
Omfattende installationsvejledning til DIGITUS afskærmede patchpaneler, der dækker trækaflastning, kabelfastgørelse og tilslutningsprocedurer. Indeholder produktspecifikationer og oplysninger om RoHS-overholdelse.
Preview DIGITUS 16/24FE (PoE) + 2G Combo PoE Switch Brugermanual
Brugermanual til DIGITUS 16/24FE (PoE) + 2G Combo PoE-switche (DN-95342 Rev.2, DN-95343 Rev.2), der beskriver funktioner, hardware, installation og specifikationer for netværksforbindelse.
Preview DIGITUS 8-ports administreret Gigabit Ethernet-switch brugermanual | DN-651123, DN-651125
Omfattende brugermanual til DIGITUS 8-Port Managed Gigabit Ethernet Switch (model DN-651123 og DN-651125). Lær om produktfunktioner, specifikationer, installation og netværkskonfiguration.
Preview DIGITUS felttermineringskobler CAT 6A, 500 MHz installationsvejledning
Trin-for-trin installationsvejledning til DIGITUS Field Termination Coupler CAT 6A, 500 MHz (DN-93912), inklusive afisolering, ledningshåndtering og endelig montering.
Preview DIGITUS vægkabinet SOHO PRO-serien hurtig installationsvejledning
Trinvise instruktioner til installation af DIGITUS Wall Housing SOHO PRO Series netværksskabe, inklusive modellerne DN-49100 til DN-49105.
Preview DIGITUS 4-ports industriel Fast Ethernet-switch - Sikkerheds- og betjeningsvejledning
Vigtige sikkerhedsnoter og betjeningsvejledninger til DIGITUS 4-Port Fast Ethernet Network Switch (DN-651130), en industriel, ikke-administreret switch med 1 SFP FE uplink.