1. Introduktion
The STI FS200 SpecSeal Ready Sleeve Kit is engineered to provide a UL Classified and code-compliant firestop penetration for cables through fire-rated walls or floors. This kit offers a complete solution, simplifying the installation process and ensuring fire safety compliance.
The FS200 sleeve is suitable for installation in barriers up to 10 inches (250 mm) thick. When properly installed, the sleeve maintains the fire resistance rating of the barrier, preventing the spread of fire and smoke.
2. Sikkerhedsoplysninger
Adherence to safety guidelines is crucial during installation. Always observe the following precautions:
- Brug altid passende personlige værnemidler (PPE), herunder sikkerhedsbriller og handsker.
- Sørg for, at arbejdsområdet er godt ventileret.
- Consult local building codes and fire safety regulations to ensure compliance.
- Do not modify the product in any way not specified in these instructions.
- This product is intended for new cable installations only and cannot be used to retrofit existing violations without proper assessment by a qualified professional.
3. Produktet er slutview
3.1 Komponenter
The STI FS200 Ready Sleeve Kit includes the following components:
- 2-inch (51 mm) Sleeve (galvanized steel)
- Escutcheon Plates
- Pakninger
- Brandbeskyttelsesmasse
3.2 Funktioner
Key features of the FS200 kit include:
- Provides a comprehensive, UL Classified solution for cable penetrations.
- Eliminates the need for cutting conduit and strut, saving installation time.
- Designed for quick and efficient installation.
- No external caulking is required for sealing.

Figur 1: The STI FS200 2-inch firestop sleeve kit. This image displays the main components of the kit, including the galvanized steel sleeve, escutcheon plates, and securing hardware.
4. Opsætning og installation
Follow these steps for proper installation of the STI FS200 Firestop Sleeve Kit:
- Forbered åbningen: Create a circular opening in the fire-rated wall or floor. A 2.5-inch hole saw is recommended for optimal fit. For accurate alignment, predrill with a smaller bit before using the hole saw.
- Insert the Sleeve: Position the 2-inch sleeve within the prepared opening. The sleeve should be centered within the barrier, extending an equal distance from both sides of the wall or floor.
- Sikre komponenter: Place the gaskets and escutcheon plates onto the sleeve on both sides of the barrier. Secure them firmly using the provided hardware. Ensure a snug fit against the barrier surface.
- Apply Firestop Putty: Use the provided firestop putty to seal any remaining annular space between the sleeve and the opening, and around any cables passing through the sleeve. Ensure a complete and tight seal to prevent the passage of smoke and fire.
- Kabel installation: Route cables through the installed sleeve. Ensure that the cables do not exceed the fill capacity of the sleeve and that the firestop putty maintains its seal around all cables.
Vigtig bemærkning: This system is designed for new cable installations. Retrofitting existing penetrations may require different methods or additional firestop materials. Consult relevant firestop listings and local codes.
5. Betjeningsvejledning
The STI FS200 Firestop Sleeve Kit functions as a passive fire protection system. Once correctly installed, it operates continuously to maintain the fire resistance rating of the penetrated barrier. There are no active operational steps required for the sleeve itself.
Its primary function is to prevent the passage of flame, smoke, and hot gases through openings created for cables in fire-rated constructions.
6. Vedligeholdelse
To ensure the continued effectiveness of the firestop system, periodic inspection and maintenance are recommended:
- Regelmæssig inspektion: Visually inspect the firestop sleeve and the surrounding firestop material at regular intervals, or as required by local codes. Check for any signs of damage, degradation, or dislodgement.
- Seglintegritet: Verify that the firestop putty around the cables and between the sleeve and the barrier remains intact and provides a complete seal.
- Cable Modifications: If cables are added, removed, or modified, ensure that the firestop system is re-sealed according to the manufacturer's instructions and relevant firestop listings to maintain its fire rating.
- Damage Repair: Any damage to the sleeve or firestop material should be repaired immediately using approved STI firestop products and methods.
7. Fejlfinding
This section addresses common issues that may arise during or after installation:
- Issue: Sleeve not fitting correctly in the opening.
Løsning: Verify that the hole size in the barrier is approximately 2.5 inches. Ensure the barrier thickness does not exceed the maximum 10-inch limit for the FS200 sleeve. - Issue: Visible gaps or openings around the sleeve or cables after installation.
Løsning: Reapply or add additional firestop putty to completely fill all annular spaces and ensure a tight, continuous seal around the sleeve and all cables. - Issue: Concerns about fire code compliance.
Løsning: Review the installation against the specific UL Classified listings for the STI FS200. Consult local fire safety authorities or a qualified firestop contractor for verification and guidance.
8. Specifikationer
| Specifikation | Detalje |
|---|---|
| Modelnummer | FS200 |
| Fabrikant | STI (Specified Technologies Inc.) |
| Sleeve Size | 2 inches (51 mm) Trade Size |
| Maximum Barrier Thickness | 10 tommer (250 mm) |
| ASIN | B079DWV4TC |
| Første ledige dato | 6. februar 2012 |
9. Garanti og support
For detailed warranty information regarding the STI FS200 Firestop Sleeve Kit, please refer to the official documentation provided by Specified Technologies Inc. (STI) or visit their official webwebsted.
For technical support, product inquiries, or assistance with specific application requirements, please contact STI customer service directly through their official channels.