1. Introduktion
The Honeywell TH6100AF2004 T6 Pro-1 Heat Slab Sensor Thermostat is designed to provide precise temperature control for heating systems, particularly those utilizing slab or floor heating. This thermostat offers flexible climate control options, allowing management of ambient air temperature, floor temperature, or a combination of both with defined limits. Its programmable features contribute to energy efficiency and enhanced comfort.

2. Nøglefunktioner
- 1-Stage Heat Only: Designed for single-stage varmesystemer.
- Flexible Climate Control:
- Ambient Air Temperature (A): Controls based on room air temperature.
- Floor Temperature (F): Controls based on the temperature of the floor slab using a remote sensor.
- Air Temperature with Min/Max Floor Limits (AF): Controls air temperature while maintaining floor temperature within specified minimum and maximum limits for comfort and floor protection.
- Antifreeze Temperature Protection: Prevents pipes from freezing in unoccupied spaces.
- Boiler Short Cycling Protection: Extends the life of heating equipment.
- Programmerbare muligheder: Supports 7-day, 5-2-day, or 5-1-1-day scheduling, or non-programmable operation.
- Vacation Hold Settings: Allows for extended temperature holds during absences.
- Økonomitilstand: Overrides floor low limit settings during 'away' and 'sleep' periods to conserve energy.
- Stort LCD-display: Overskuelig og letlæselig skærm.
- Tryk knap kontrol: Intuitive interface for adjustments.

3. Pakkens indhold
Bekræft, at din pakke indeholder følgende varer:
- Honeywell TH6100AF2004 T6 Pro-1 Thermostat
- Universal Mounting Plate (UWP)
- Standard installationsadapter (J-box adapter)
- Cover Plate (for covering old thermostat marks)
- Monteringsudstyr (skruer, ankre)
- Floor Temperature Sensor (wired)
- Skruetrækker

4. Opsætning og installation
4.1. Sikkerhedsoplysninger
ADVARSEL: Elektrisk fare.
Disconnect power at the circuit breaker or fuse box before installation to prevent electrical shock or equipment damage. Installation should be performed by a qualified technician. Read all instructions carefully before proceeding.
4.2. Ledninger
The TH6100AF2004 thermostat is designed for 24V AC systems. Ensure your heating system is compatible. Refer to your heating system's manual for specific wiring diagrams. Connect wires to the Universal Wiring Plate (UWP) terminals as indicated in the thermostat's wiring diagram. The floor sensor connects to the 'S1' and 'S2' terminals.

4.3. Montering
- Turn off power to your heating system at the circuit breaker.
- Fjern din gamle termostat.
- Mount the UWP to the wall using the provided screws and anchors. Ensure it is level.
- Route the floor sensor cable to the desired location in the floor slab and connect it to the S1 and S2 terminals on the UWP.
- Connect the system wires to the appropriate terminals on the UWP.
- Align the thermostat with the UWP and push it firmly until it snaps into place.
- Genopret strømmen til dit varmesystem.
5. Betjeningsvejledning
5.1. Display overview
The large LCD display shows the current temperature, setpoint temperature, time, system mode, and fan status. Buttons below the display allow for mode selection, menu access, and temperature adjustments.

5.2. Indstilling af temperatur
To adjust the setpoint temperature, use the + or - buttons located below the display. The display will show the new setpoint briefly before returning to the current temperature.
5.3. Mode Selection (Heat, Off)
Tryk på Mode button to cycle through available system modes: Varme og Slukket. Vælge Varme for active heating or Slukket to disable the heating system.
5.4. Programming Schedule
The thermostat supports programmable schedules (7-day, 5-2-day, 5-1-1-day) or non-programmable operation. Access the Menu to configure your desired schedule. Follow the on-screen prompts to set specific temperatures for different times of the day and days of the week (e.g., Wake, Away, Home, Sleep periods).
5.5. Floor Temperature Control Options
The thermostat offers three control options, configurable in the installer setup menu:
- A (Ambient Air Temperature): The thermostat controls based solely on the air temperature sensor. The floor sensor is not actively used for control.
- F (Floor Temperature): The thermostat controls based solely on the floor sensor. The air temperature sensor is not actively used for control.
- AF (Ambient Air Temperature with Min/Max Floor Limits): The thermostat primarily controls based on the air temperature sensor, but will activate heating if the floor temperature drops below a set minimum limit, or deactivate if it exceeds a set maximum limit. This protects the floor and enhances comfort.
6. Vedligeholdelse
6.1. Rensning
Rengør termostatens yderside med en blød, tør klud.amp klud. Brug ikke slibende rengøringsmidler eller opløsningsmidler. Undgå at sprøjte væsker direkte på termostaten.
6.2. Sensorpleje
The floor temperature sensor is typically embedded in the floor slab and requires no direct maintenance. Ensure the sensor cable is not damaged during installation or subsequent floor work. If the sensor is exposed, keep it clean and free from debris.
7. Fejlfinding
Hvis du oplever problemer med din termostat, kan du se følgende almindelige problemer og løsninger:
- Ingen skærm/tom skærm:
- Check the circuit breaker and ensure power is supplied to the heating system and thermostat.
- Verify that the thermostat is properly seated on the UWP.
- Heating Not Turning On:
- Ensure the system mode is set to Varme.
- Increase the setpoint temperature above the current room temperature.
- Check for error messages on the display.
- Verify wiring connections at the UWP.
- Unøjagtige temperaturmålinger:
- Sørg for, at termostaten ikke udsættes for direkte sollys, træk eller varmekilder.
- If using a floor sensor, ensure it is correctly installed and not damaged.
- Thermostat Not Responding to Button Presses:
- A temporary power cycle (turn off power at breaker for 30 seconds, then restore) may resolve the issue.
If problems persist after attempting these troubleshooting steps, contact customer support.
8. Specifikationer
| Feature | Specifikation |
|---|---|
| Mærke | Honeywell |
| Modelnavn | Honeywell T6 Pro-1 |
| Modelnummer | TH6100AF2004 |
| Controller type | Tryk knap |
| Speciel funktion | 7-day, 5-2-day, 5-1-1-day programmable or non-programmable |
| Farve | Hvid |
| Specifikke anvendelser af produktet | Boiler, Heat Slab |
| Temperaturkontrol type | Auto, Heat, Off |
| Forbindelsesteknologi | Kablet |
| Inkluderede komponenter | Thermostat, Floor Sensor |
| Strømkilde | AC/DC (24 volt) |
| Varens vægt | 13 ounces (0.81 pund) |
| Produktdimensioner | 15.75 x 12.95 x 6.35 tommer |
| Display Type | LCD |
| Monteringstype | Vægmontering |

9. Garanti og support
9.1. Garantioplysninger
This Honeywell product is covered by a limited warranty. For specific details regarding warranty coverage, duration, and terms, please refer to the warranty card included with your product or visit the official Honeywell webwebsted. Gem din købsbevis til garantikrav.
9.2. Kundesupport
For technical assistance, troubleshooting guidance beyond this manual, or warranty inquiries, please contact Honeywell Customer Support. Contact information can typically be found on the product packaging, the official Honeywell website, or by calling the number provided in your product documentation.