1. Introduktion
This manual provides essential instructions for the installation, operation, and maintenance of your PHASAK SIRIUS PH 7322 Uninterruptible Power Supply (UPS). The SIRIUS Interactive series offers reliable protection against power variations and spikes, ensuring stable and clean energy for connected equipment. Please read this manual thoroughly before using the device to ensure proper function and safety.
2. Sikkerhedsinstruktioner
Overhold følgende sikkerhedsforanstaltninger for at forhindre personskade og beskadigelse af UPS'en eller tilsluttet udstyr:
- Åbn ikke UPS'en casing. Der er ingen dele indeni, som brugeren kan servicere. Overlad al service til kvalificeret servicepersonale.
- Do not connect appliances that could overload the UPS, such as laser printers, to battery-backed outlets (use surge-only outlets for these).
- Ensure the UPS is placed in a well-ventilated area, away from direct sunlight, heat sources, and moisture.
- Tilslut kun UPS'en til en jordet vekselstrømsstikkontakt.
- In case of emergency, press the power button to turn off the UPS and disconnect it from the AC power source.
- The UPS contains internal batteries. Do not dispose of the UPS or its batteries in fire. Batteries may explode.
3. Produktfunktioner
The PHASAK SIRIUS PH 7322 UPS is equipped with several features designed for optimal performance and protection:
- LCD / LED function display for real-time status monitoring.
- Automatisk voltage Regulator (AVR) to stabilize input voltage uden at bruge batteristrøm.
- Auto restart/auto-reload function for convenience after power restoration.
- Compatibility with generators for flexible power input.
- Communication: 1 x USB port for connection to a computer.
- Outlets: 3 x Schuko outlets with battery backup and surge protection, and 1 x Schuko outlet with surge protection only.
4. Opsætning
4.1 Udpakning og placering
- Pak forsigtigt UPS'en ud, og inspicer den for eventuelle transportskader.
- Place the UPS on a flat, stable surface in a clean, dry, and well-ventilated environment. Avoid areas with excessive dust, humidity, or extreme temperatures.
- Ensure there is adequate clearance around the UPS for proper airflow, especially around ventilation openings.
4.2 Tilslutning af UPS'en
Refer to the rear panel diagram for outlet identification.

Figure 1: Rear Panel Connections. This image displays the back of the PHASAK SIRIUS PH 7322 UPS, highlighting the four Schuko outlets (three with surge and battery backup, one with surge protection only), the USB communication port, and the circuit breaker button.
- Tilslut til vekselstrøm: Sæt UPS-strømledningen i en jordet stikkontakt.
- Tilslut udstyr:
- Connect critical equipment (e.g., computers, monitors, network devices) to the Surge & Battery outlets (typically 3 outlets). These outlets provide both surge protection and battery backup during power outages.
- Connect non-critical equipment that requires only surge protection (e.g., laser printers, scanners) to the Kun overspænding outlet (typically 1 outlet).
- USB-kommunikation: Connect the provided USB cable from the UPS USB port to your computer. Install the PowerGuide management software (available from Phasak's website) to enable advanced monitoring and shutdown features.
Allow the UPS to charge for at least 8 hours before initial use to ensure full battery capacity.
5. Betjening
5.1 Tænd/sluk

Figure 2: Front Panel Display and Controls. This image shows the front of the PHASAK SIRIUS PH 7322 UPS, featuring the LCD display that shows input/output voltage and status icons, and the main power button.
- For at tænde: Press and hold the power button on the front panel for approximately 2 seconds until you hear a beep and the display illuminates.
- For at slukke: Press and hold the power button for approximately 2 seconds until you hear a beep and the display turns off.
5.2 LCD-displayinformation
The LCD display provides real-time status information about the UPS:
- Input bindtage: Viser den aktuelle voltage from the utility power.
- Udgang Voltage: Viser voltage leveret af UPS'en til tilsluttet udstyr.
- Batteriniveau: Angiver den resterende batteriopladning.
- Belastningsniveau: Viser procententagaf UPS'ens kapacitet, der bruges af tilsluttet udstyr.
- Statusikoner: Various icons indicate operational mode (e.g., AC mode, battery mode, AVR active, fault). Refer to the full software manual for detailed icon explanations.
5.3 Automatisk Voltage Forordning (AVR)
UPS'en korrigerer automatisk mindre volumentage fluctuations (sags and surges) without switching to battery power, extending battery life and providing stable power to your devices.
5.4 Batteritilstand
Under en magt outage, the UPS will automatically switch to battery power. An audible alarm will sound, and the display will indicate battery mode. The alarm will typically sound more frequently as the battery level becomes critically low, signaling that connected equipment should be safely shut down.
6. Vedligeholdelse
- Rensning: Use a dry, soft cloth to clean the exterior of the UPS. Do not use liquid or aerosol cleaners.
- Batteripleje: To maintain optimal battery life, ensure the UPS is connected to AC power at all times. If the UPS is stored for an extended period, recharge it every 3 months for at least 8 hours.
- Udskiftning af batteri: Batteries are not user-replaceable. Contact qualified service personnel for battery replacement.
- Ventilation: Regularly check that the ventilation openings are clear of dust and obstructions to prevent overheating.
7. Fejlfinding
| Problem | Mulig årsag | Løsning |
|---|---|---|
| UPS'en tænder ikke. | No AC input power; Low battery; UPS fault. | Ensure UPS is plugged into a live AC outlet. Allow UPS to charge for several hours. If problem persists, contact support. |
| UPS beeps continuously in AC mode. | Overbelastning; Intern fejl. | Reduce the load by disconnecting non-essential equipment. If problem persists, contact support. |
| UPS'en skifter ofte til batteritilstand. | Unstable AC input power; AVR working. | This may be normal if AC power is fluctuating. If it happens excessively, check the AC power source or contact an electrician. |
| Connected equipment loses power during outage. | Equipment connected to surge-only outlet; Battery depleted; UPS overloaded. | Ensure critical equipment is connected to battery-backed outlets. Allow battery to charge. Reduce load. |
8. Specifikationer
| Model | PH 7322 |
| Mærke | Phasak |
| Output Wattage | 2260 watt |
| Maksimal effekt | 2260 watt |
| Voltage | 220V |
| Ampslette | 9 Amps |
| Samlet strømudtag | 3 (Battery & Surge) + 1 (Surge Only) |
| Battericellesammensætning | Forseglet blysyre |
| Formfaktor | Rack |
| Produktdimensioner | 60 x 60 x 85 cm |
| Varens vægt | 10.8 kilo |
| Kommunikationsport | 1 x USB |
9. Garanti og support
All PHASAK Uninterruptible Power Systems come with a 2-year "In Situ" warranty. For technical support, warranty claims, or service inquiries, please contact your local Phasak distributor or visit the official Phasak webwebsted for kontaktoplysninger.
Please have your product model (PH 7322) and purchase information ready when contacting support.