AMS 405.57

AMS 405.57 1 1/2" x 12" Aluminum Liner User Manual

Model: 405.57 | Brand: AMS

Indledning

This manual provides essential information for the proper use, maintenance, and care of your AMS 405.57 1 1/2" x 12" Aluminum Liner. This liner is designed for use with various 1-1/2" AMS core samplers, facilitating efficient and reliable sample samling.

Produkt overview

AMS 1 1/2 inch by 12 inch aluminum liner

Billedbeskrivelse: A single, cylindrical aluminum tube, approximately 12 inches in length, with an outer diameter of 1 1/2 inches. The surface appears brushed or slightly textured, indicative of aluminum material. Both ends are open, showing the hollow interior of the liner. This image illustrates the primary component of the AMS 405.57 product.

The AMS 405.57 Aluminum Liner is a precision-engineered component for soil and sediment sampling. It features a 1-1/2 inch outer diameter and a 12-inch length. The wall thickness is approximately 0.060 inches, providing a balance of durability and lightweight handling. This liner is specifically designed to integrate seamlessly with compatible AMS core samplers.

Nøglefunktioner:

Opsætning

Before using the aluminum liner, ensure you have the appropriate AMS core sampler that is compatible with a 1-1/2 inch liner. The liner is intended to be inserted into the core sampler barrel to collect and retain soil or sediment samples.

  1. Inspect the Liner: Carefully examine the aluminum liner for any signs of damage, dents, or deformities that could affect its performance or fit within the core sampler.
  2. Clean the Liner: Ensure the interior and exterior of the liner are clean and free from debris, dirt, or residues from previous uses. Use a soft cloth and mild detergent if necessary, then rinse thoroughly and dry completely.
  3. Prepare Core SampLæs: Refer to your AMS core sampler's manual for specific instructions on preparing it for liner insertion. Ensure the sampler barrel is clean and free of obstructions.
  4. Indsæt foring: Gently slide the aluminum liner into the designated slot or barrel of your 1-1/2" AMS core sampler. Ensure it seats properly and securely. Do not force the liner, as this could cause damage to either the liner or the sampler.
  5. Bekræft pasform: Once inserted, confirm that the liner is flush and stable within the core sampler, ready for sampling operationer.

Betjeningsvejledning

The aluminum liner functions as a disposable or reusable sleeve within a core sampler to preserve the integrity of collected samples. Its operation is directly tied to the use of the core sampler itself.

  1. Attach Core SampLæs: Assemble your AMS core sampler with the aluminum liner installed, following the sampler's specific instructions.
  2. Perform Sampling: Use the core sampler as directed by its manual to collect the desired soil or sediment sample. The liner will fill with the sample as the sampler penetrates the ground.
  3. Retrieve SampLæs: Carefully extract the core sampler from the ground.
  4. Remove Liner: Once the core sampler is retrieved, gently remove the aluminum liner containing the sample. This may involve detaching the sampler's cutting tip or other components as per your sampler's design.
  5. Seal Sampdet: Hvis sample is to be transported or stored, cap both ends of the liner immediately to prevent sample loss, contamination, or disturbance. Use appropriate end caps or sealing methods.
  6. Label Liner: Clearly label the liner with all necessary sample identification information (e.g., date, time, location, depth, project ID).

Note: Always refer to the specific operating instructions of your AMS core sampler for detailed sampling procedures. The aluminum liner is a passive component designed to hold the sample.

Opretholdelse

Proper maintenance extends the life of your aluminum liner, especially if intended for multiple uses, and ensures sampintegriteten.

Fejlfinding

This section addresses common issues that may arise during the use of your aluminum liner.

ProblemMulig årsagLøsning
Liner does not fit into core sampler.
  • Incorrect liner size.
  • Liner is dented or deformed.
  • Core sampler barrel is obstructed or damaged.
  • Verify liner dimensions (1 1/2" OD) against sampler specifications.
  • Inspect liner for damage; replace if necessary.
  • Clean and inspect core sampler barrel.
Sample is difficult to extract from liner.
  • Compacted sample.
  • Rough interior surface of liner (due to wear or damage).
  • Brug passende sample extrusion tools.
  • Consider replacing the liner if interior surface is compromised.
Liner gets stuck in core sampler.
  • Liner or sampler barrel is dirty.
  • Liner is slightly deformed.
  • Excessive force during insertion.
  • Clean both components thoroughly.
  • Inspect liner for subtle deformities; replace if needed.
  • Always insert gently.

Specifikationer

AttributDetalje
Modelnummer405.57
Udvendig diameter1 1/2 tommer (ca. 3.81 cm)
Længde12 tommer (ca. 30.48 cm)
VægtykkelseApproximately 0.060 inches (approx. 1.52 mm)
MaterialeAluminium
Omtrentlig vægt1 pund (ca. 0.45 kg)
Pakkedimensioner14 x 4 x 4 tommer
FabrikantAMS Incorporated
OprindelseslandUSA
Dato først tilgængelig12. december 2017

Garanti og support

Specific warranty information for the AMS 405.57 Aluminum Liner is not provided in this document. For details regarding product warranty, technical support, or replacement parts, please contact AMS Incorporated directly through their official webwebsted eller kundeservicekanaler.

Fabrikant: AMS Incorporated

Please refer to the manufacturer's official resources for the most current support information.

Relaterede dokumenter - 405.57

Preview ams AS5600L Adapterkort Eval Kit Manual
Denne manual indeholder omfattende oplysninger om ams AS5600L-WL_EK_AB adapterkortet, herunder sættets indhold, kortbeskrivelse, monteringsvejledning, pinout-detaljer, I2C-tilstandsdrift, hardwarediagrammer, printkortlayout og bestillingsoplysninger.
Preview ams AS5048 14-bit roterende positionssensor brugermanual
Denne brugermanual indeholder detaljerede oplysninger om ams AS5048, en 14-bit roterende positionssensor med digital vinkel og PWM-udgang. Den dækker AS5048-adapterkortet, montering, pinout, driftstilfælde (SPI, Daisy Chain), firmwarekodning, f.eks.amples og hardwarediagrammer. Essentielt for ingeniører, der integrerer denne sensor i deres systemer.
Preview ams AS5048 Adapter Board Evaluation Kit Manual
This manual details the ams AS5048 Adapter Board (AS5048-EK-AB), an evaluation kit for the AS5048 magnetic position sensor. It covers hardware, operation modes (SPI, I2C), software examples, and contact information for ams AG.
Preview ams AS5048 Adapter Board Evaluation Kit Manual
User manual for the ams AS5048 Adapter Board Evaluation Kit (AS5048-EK-AB), detailing its features, pinout, mounting, operation cases (SPI modes), hardware schematics, PCB layout, and contact information.
Preview AMS vægur brugsanvisning
Betjeningsvejledning til AMS vægure, der dækker installation, udskiftning og generel brug af batterier på flere sprog.
Preview TSL2521 EVM brugervejledning: Evalueringssæt til omgivende lyssensor
Brugervejledning til ams TSL2521 EVM, der beskriver dens funktioner som en meget følsom omgivende lyssensor med selektiv flimmerdetektion og hurtig sampKan bruges bag OLED eller som ekstraudstyr til kameraet. Indeholder hardware- og softwarebeskrivelser, opsætning og juridiske oplysninger.