REDARC SBI12

REDARC Smart Start SBI12 12V 100A Brugsanvisning

Model: SBI12

1. Introduktion

This manual provides comprehensive instructions for the installation, operation, and maintenance of the REDARC Smart Start SBI12 12V 100A Battery Isolator. The SBI12 is a microprocessor-controlled device designed to manage dual battery systems by protecting the primary (start) battery from excessive discharge while allowing the auxiliary battery to power non-essential loads. It functions as a solenoid priority system, ensuring efficient charging of your secondary battery when the vehicle is in motion.

2. Produktet er slutview

The REDARC Smart Start SBI12 offers advanced battery management for 12V dual battery systems, providing a continuous rating of 100A. Key features include:

Unlike diode-type isolators, the SBI12 avoids voltage drop issues, ensuring more efficient power transfer.

3. Sikkerhedsoplysninger

Please read and understand all safety warnings and instructions before installing or operating the REDARC Smart Start SBI12. Failure to do so may result in injury, damage to the product, or damage to your vehicle.

4. Opsætning og installation

Proper installation is crucial for the optimal performance and longevity of your SBI12. The unit should be mounted securely in a dry, well-ventilated area, away from direct heat sources.

4.1 Komponentidentifikation

REDARC Smart Start SBI12 front view

Billede 4.1.1: Front view of the REDARC Smart Start SBI12 battery isolator, showing the red housing with the REDARC logo and "Designed and manufactured in Australia" text, along with the main terminals and wiring connections.

REDARC Smart Start SBI12 side view

Billede 4.1.2: Side view of the REDARC Smart Start SBI12, illustrating the compact design and the robust terminals with protective caps.

REDARC Smart Start SBI12 alternate side view

Billede 4.1.3: En anden side view of the REDARC Smart Start SBI12, highlighting the wiring connections including the ground wire labeled "GND".

4.2 Ledningsdiagram

The following diagram illustrates a standard installation for the Smart Start SBI12 in a dual battery system.

Smart Start standard installation wiring diagram

Billede 4.2.1: Standard installation wiring diagram for the REDARC Smart Start SBI12. It shows the connection between the start battery and the auxiliary battery via the SBI12, with fuses on both positive lines and ground connections for both batteries and the isolator.

4.3 Kontrol før installation

5. Betjeningsvejledning

The REDARC Smart Start SBI12 operates automatically to manage your dual battery system.

6. Vedligeholdelse

The REDARC Smart Start SBI12 is designed for minimal maintenance. However, periodic checks are recommended to ensure optimal performance:

7. Fejlfinding

The SBI12 incorporates fault detection and an LED indicator to assist with troubleshooting.

Symptom / LED IndicationMulig årsagLøsning
SBI12 not engaging (auxiliary battery not charging)
  • Primary battery voltage for lavt.
  • Løse eller korroderede forbindelser.
  • Sprunget sikring.
  • Faulty ground connection.
  • Check primary battery charge.
  • Inspect and clean all connections.
  • Kontroller og udskift om nødvendigt sikringer.
  • Verify ground connection integrity.
LED indicates fault (e.g., flashing pattern)
  • Voltage drop detected.
  • Over-voltage tilstand.
  • Excessive current draw.
  • Intern fejl.
  • Check wiring for resistance, ensure proper gauge.
  • Verify vehicle charging system output.
  • Reduce load on auxiliary battery or check for short circuits.
  • Contact REDARC support if issues persist after checking external factors.
SBI12 remains engaged when engine is off
  • Defekt enhed.
  • Forkert ledningsføring.
  • Bekræft ledningsføringen i forhold til diagrammet.
  • Contact REDARC support.

For detailed fault code interpretations or persistent issues, refer to the official REDARC documentation or contact their technical support.

8. Specifikationer

ModelnummerSBI12
MærkeREDARC
Voltage12 volt DC
Kontinuerlig vurdering100 Amps
Varens vægt9.1 ounce (ca. 258 gram)
Pakkedimensioner3.7 x 2.99 x 2.95 tommer (ca. 9.4 x 7.6 x 7.5 cm)
Producentens varenummerSBI12

9. Garanti og support

For specific warranty information, please refer to the documentation provided with your REDARC Smart Start SBI12 or visit the official REDARC webwebsted.

If you require technical assistance, have questions about installation, or need help choosing the best dual battery setup for your needs, REDARC offers support resources.

REDARC Support:

Relaterede dokumenter - SBI12

Preview REDARC Smart Start batteriafbryder SBI12, SBI24, SBI212, SBI224 - Installations-, betjenings- og sikkerhedsmanual
Comprehensive guide for the REDARC Smart Start Battery Isolator, covering models SBI12, SBI24, SBI212, SBI224, and dual sensing variants. Includes specifications, installation instructions, wiring diagrams, fault diagnosis, FAQs, safety precautions, and warranty information.
Preview GPC monteringssæt til REDARC ALPHA R 50A - INEOS GRENADIER installationsvejledning
Detaljeret installationsvejledning til GPC-monteringssættet til REDARC ALPHA R 50A dobbeltbatterisystemet, specifikt til INEOS GRENADIER-køretøjet. Indeholder trinvise instruktioner, sikkerhedsadvarsler og idriftsættelsesoplysninger.
Preview REDARC 12V til 24V enkeltkredsvolumentage Boostere: VI180D, VI360D, VI720D Brugermanual
Dette dokument indeholder detaljerede specifikationer, funktioner, installationsvejledning og garantioplysninger for REDARC's VI-serie 12V til 24V enkeltkredsvolumen.tage Boostere, inklusive modellerne VI180D, VI360D og VI720D.
Preview REDARC ALPHA 50 BCDC Installationsvejledning
Installationsvejledning til REDARC ALPHA 50 BCDC monteringssættet til dobbeltbatterisystemet, der indeholder trinvise instruktioner, nødvendige værktøjer, medfølgende komponenter og ledningsføringsvejledning til køretøjsapplikationer.
Preview REDARC SRPA-serien af ​​solcelleregulatorer: SRPA0120, SRPA0240, SRPA0360 - Brugermanual og specifikationer
Få detaljerede oplysninger om REDARC's SRPA-serie PWM-solcelleregulatorer (SRPA0120, SRPA0240, SRPA0360). Denne manual dækker installation, sikkerhed, specifikationer, systemledningsføring og garanti for 12V- og 24V-batterisystemer.
Preview REDARC BCDC ALPHA 100R: 12V 100A DC-DC batterioplader med Bluetooth installationsvejledning
Explore the REDARC BCDC ALPHA 100R, a 12V 100A DC-DC battery charger featuring smart battery monitoring and Bluetooth connectivity. This guide provides installation, configuration, and operation details for optimal vehicle power management.