Trane KIT18110

Trane KIT18110 OEM Opgraderet Ovn Kontrolkort Sæt Instruktionsmanual

Model: KIT18110

Indledning

This manual provides detailed instructions for the installation, operation, and maintenance of the Trane KIT18110 OEM Upgraded Furnace Control Board Kit. This kit is designed as an American Standard / Trane OEM component for furnace units built after 1995. It includes the control board (CNT07541), ignitor, wire harness, and bracket.

Vigtig bemærkning: For downflow units built in 1999 and earlier, use KIT18109. For all other units built after 1995, use KIT18110.

Sikkerhedsoplysninger

ADVARSEL: Installation and servicing of heating, ventilation, and air conditioning (HVAC) equipment can be hazardous due to system pressure, electrical components, and equipment location. Only trained and qualified service personnel should install, repair, or service HVAC equipment.

Pakkens indhold

The Trane KIT18110 kit typically includes the following components:

Trane KIT18110 Furnace Control Board Kit components

Image: The Trane KIT18110 furnace control board kit, showing the main circuit board, ignitor, and mounting hardware.

Kompatibilitet

This kit is an OEM replacement for various American Standard and Trane units built after 1995. It supersedes several older control board models. Always verify compatibility with your specific furnace model before installation.

Replaces / Supersedes Part Numbers:

Commonly Found in Models:

This kit is commonly found in the following A/TDX and A/TUX Gas Furnace Models:

Trane OEM Component stamp

Image: A stamp indicating "Trane OEM Component," signifying genuine parts.

Installation/opsætning

This procedure is intended for qualified technicians. Refer to your furnace's specific service manual for detailed wiring diagrams and safety precautions.

  1. Strømafbrydelse: Locate the main power switch for your furnace and turn it OFF. Additionally, turn off power at the circuit breaker or fuse box. Verify power is off using a voltage meter.
  2. Adgangskontroltavle: Open the furnace access panel to expose the existing control board.
  3. Dokumentledningsføring: Before disconnecting any wires, take clear photographs of all existing wiring connections to the old control board. Label wires if necessary to ensure correct re-connection.
  4. Frakobl ledninger: Frakobl forsigtigt alle ledninger fra det gamle styrekort.
  5. Fjern gammelt bræt: Unscrew or unclip the old control board from its mounting location.
  6. Installer nyt kort: Mount the new Trane KIT18110 control board using the provided bracket and screws. Ensure it is securely fastened.
  7. Tilslut ledninger: Refer to your photographs and the wiring diagram in your furnace manual to connect all wires to the new control board. Pay close attention to terminal markings (e.g., R, W, Y, G, C).
  8. Install Ignitor: Replace the old ignitor with the new one provided in the kit, ensuring proper seating and connection to the control board via the wire harness.
  9. Sikre paneler: Luk og fastgør alle adgangspaneler til ovnen.
  10. Gendan strøm: Restore power to the furnace at the circuit breaker or fuse box, then turn on the main power switch for the furnace.
  11. Test drift: Initiate a heating cycle to verify proper furnace operation, including ignition, fan operation, and temperature control. Observe for any error codes or unusual behavior.

Operation

The Trane KIT18110 control board is an integrated furnace control that manages the sequence of operation for your furnace. Once correctly installed, it will automatically control the ignition, fan, and safety functions based on signals from the thermostat and internal sensors. No direct user interaction with the control board is required for normal operation.

Refer to your furnace's user manual for instructions on setting your thermostat and general furnace operation.

Opretholdelse

The control board itself typically requires no routine maintenance. However, regular maintenance of your furnace system is crucial for its longevity and efficient operation. This includes:

Always disconnect power before performing any maintenance on the furnace.

Fejlfinding

The control board features diagnostic LED indicators that can help identify system faults. Consult your furnace's service manual for a detailed list of error codes and their meanings. Common issues and initial checks include:

If you are unable to resolve an issue, contact a qualified HVAC technician.

Specifikationer

VaremodelnummerKIT18110
FabrikantTrane
KompatibilitetAmerican Standard / Trane units built after 1995
Sættet inkludererControl Board (CNT07541), Ignitor, Wire Harness, Bracket
Pakkedimensioner12.09 x 7.2 x 5.08 tommer
Varens vægt15.17 ounce

Garantioplysninger

Specific warranty details for the Trane KIT18110 control board kit are typically provided by the point of purchase or Trane directly. It is recommended to retain your purchase receipt and consult the official Trane warranty documentation for your specific product. Generally, OEM parts carry a limited warranty against manufacturing defects.

Støtte

For technical assistance, troubleshooting beyond this manual, or warranty claims, please contact your authorized Trane dealer or a qualified HVAC service professional. You may also visit the official Trane webwebsted for yderligere ressourcer og kontaktoplysninger.

Relaterede dokumenter - KIT18110

Preview Trane & American Standard S8-seriens gasovn installations-, drifts- og vedligeholdelsesmanual
Omfattende vejledning til installation, drift og vedligeholdelse af Trane og American Standard S8-serien af ​​opstrøms-/nedstrøms-/horisontal gasfyrede 1-Stage og 2-Stage Inducerede trækovne med højeffektiv motor. Inkluderer sikkerhedsadvarsler, specifikationer, ledningsdiagrammer og fejlfinding.
Preview Trane S9V2-seriens gasovn: Installations-, drifts- og vedligeholdelsesmanual
Omfattende vejledning til installation, drift og vedligeholdelse af Trane og American Standard S9V2 serie 2-stage kondenserende gasovne med variabel hastighed. Dækker sikkerhed, installationsprocedurer, specifikationer og fejlfinding.
Preview Trane & American Standard IFC-kortfejlservicebulletin - OBLIGATORISK efterarbejde
Officiel servicebulletin fra Trane og American Standard vedrørende fejl i integreret ovnstyringsprintkort (IFC) i specifikke ovnmodeller. Detaljer om fejlkode 5, berørte modeller og obligatoriske efterbearbejdningsinstruktioner.
Preview Installations-, drifts- og vedligeholdelsesmanual til Trane/American Standard A801X-serien af ​​gasovne
Denne omfattende manual indeholder detaljerede instruktioner til installation, betjening og vedligeholdelse af Trane og American Standard A801X-serien af ​​enkeltspoler.tage inducerede gasovne. Den dækker sikkerhedsadvarsler, produktspecifikationer, installationsvejledninger, fejlfindingsprocedurer og krav til periodisk service for forskellige modeller.
Preview Trane LP-konverteringssæt installationsvejledning til Precedent tagmonterede enheder
Detaljerede installationsvejledninger til konvertering af Trane Precedent™-pakkede taghætter (6 til 25 tons) fra naturgas til propangas (LP). Indeholder sikkerhedsadvarsler, reservedelsliste og trinvise procedurer for kvalificeret personale.
Preview Trane Ultra-Low NOx-seriens installationsvejledning til pakkede gasvarme-/elektriske køleenheder
Denne installationsvejledning indeholder omfattende instruktioner til installation, drift, vedligeholdelse og fejlfinding af Trane Ultra-Low NOx-seriens enkeltpakkede gasvarme- og elektriske køleenheder (2-5 tons). Den dækker sikkerhed, krav, el, gas, opstart og komponentdetaljer.