Indledning
The Power Probe PPT5VA 5-Volt Reference Adapter is designed to work with Power Probe Tek circuit testers. This adapter reduces the output voltage from the circuit tester to a stable 5 volts, enabling safe testing and simulation of sensor reference voltages in automotive electrical systems without risking damage to sensitive components.

Image: The Power Probe PPT5VA 5-Volt Reference Adapter shown in its retail packaging, highlighting the product and its intended use with a Power Probe circuit tester.
Sikkerhedsoplysninger
Please read and understand all safety instructions before using the Power Probe PPT5VA adapter. Failure to follow these instructions may result in injury or damage to the product or vehicle components.
- Always ensure the Power Probe circuit tester is properly grounded before use.
- Overskrid ikke den specificerede indgangsvolumentage range (12-24V DC) for the Power Probe circuit tester.
- Avoid direct contact with live electrical circuits without proper insulation.
- Refer to your vehicle's service manual for specific testing procedures and voltage krav.
- This adapter is intended for use by qualified technicians.
Pakkens indhold
- 1 x Power Probe PPT5VA 5-Volt Reference Adapter
Opsætning
Follow these steps to properly connect the PPT5VA adapter to your Power Probe circuit tester:
- Ensure your Power Probe circuit tester is turned off.
- Insert the male banana plug end of the PPT5VA adapter into the female banana jack of your Power Probe circuit tester.
- Connect the tip of the PPT5VA adapter to the component or circuit you intend to test.
- Ensure the Power Probe circuit tester is properly grounded to the vehicle chassis or battery negative terminal.

Image: The PPT5VA adapter shown connected to different models of Power Probe circuit testers, demonstrating its compatibility and connection method.
Betjeningsvejledning
Once the PPT5VA adapter is correctly set up, you can begin using it for diagnostic tasks:
- With the PPT5VA adapter connected to your Power Probe circuit tester and the circuit tester properly grounded, turn on the Power Probe.
- The adapter will automatically reduce the output voltage from the Power Probe to a regulated 5 volts.
- You can now safely apply this 5-volt reference to test sensors, simulate sensor outputs, or check circuits that operate within a 0-5 volt range.
- Observe the readings on your Power Probe circuit tester's display. Note that the Power Probe's display may still show the input voltage (e.g., 12V) but the output through the adapter will be 5V.
- Always verify the circuit's requirements before applying voltage.
Opretholdelse
Proper care and maintenance will ensure the longevity and reliable performance of your PPT5VA adapter:
- Clean the adapter with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- Store the adapter in a dry, cool place, away from direct sunlight and extreme temperatures.
- Inspect the adapter for any signs of damage before each use. Discontinue use if damaged.
Fejlfinding
If you encounter issues while using the PPT5VA adapter, consider the following:
- No 5V output:
- Ensure the adapter is securely connected to the Power Probe.
- Verify the Power Probe itself is functioning correctly and receiving power.
- Check for proper grounding of the Power Probe.
- Inkonsistente aflæsninger:
- Ensure all connections are clean and secure.
- Verify the integrity of the circuit being tested.
Specifikationer
| Model | PPT5VA |
| Input bindtage | 12-24 Volts DC (from Power Probe) |
| Udgang Voltage | 5 volt DC |
| Varens vægt | 1.12 ounce |
| Produktdimensioner | 0.79 x 3.94 x 6.3 tommer |
| Fabrikant | Strømprobe |
Garantioplysninger
Power Probe products are typically covered by a manufacturer's warranty. For specific warranty terms and conditions, please refer to the documentation included with your purchase or visit the official Power Probe webwebsted for de nyeste oplysninger.
Støtte
For technical assistance, product inquiries, or further support, please visit the official Power Probe store or contact Power Probe customer service directly.