WIKA 9767070TCAL

WIKA 9767070 Industrial Pressure Gauge

Brugermanual

1. Introduktion

This user manual provides essential information for the safe and effective operation, installation, and maintenance of your WIKA 9767070 Industrial Pressure Gauge. Please read this manual thoroughly before using the device and retain it for future reference.

2. Produktet er slutview

The WIKA 9767070 Industrial Pressure Gauge is designed for precise measurement of pressure in various industrial applications. It features copper alloy wetted parts for corrosion resistance and a durable stainless steel case. This liquid/refillable gauge is suitable for gaseous or liquid samples, including those found in hydraulics and compressors.

Front view of WIKA 9767070 Industrial Pressure Gauge showing the dial, needle, and PSI markings from 0 to 160.

Figur 2.1: Front view of the WIKA 9767070 Industrial Pressure Gauge. The dial clearly displays pressure readings in PSI, ranging from 0 to 160, with a prominent needle indicating the current pressure. The WIKA logo is visible at the bottom of the dial.

Side view of WIKA 9767070 Industrial Pressure Gauge showing the stainless steel casing and bottom NPT connection.

Figur 2.2: Side view of the WIKA 9767070 Industrial Pressure Gauge. This view highlights the robust stainless steel casing and the brass 1/4" Male NPT bottom mount connection, which is used for installation into the system.

Nøglefunktioner:

  • Copper alloy wetted parts for high corrosion resistance against salty liquids.
  • Circular dial enclosed in a stainless steel case for corrosion resistance.
  • Pressure ranges from 15 psi to 15,000 psi (Note: This specific model's range is 0-160 psi).
  • Display accuracy ranges from ±1 percent of span to ±2.5 percent of span.
  • Male NPT connection with 1/8", 1/4", or 1/2" rate (This model features 1/4" NPT Male Bottom Mount).

3. Sikkerhedsoplysninger

Always adhere to the following safety precautions to prevent injury or damage to the pressure gauge and associated equipment:

  • Ensure the pressure gauge's maximum operating pressure is suitable for your application. Do not exceed the specified range.
  • Verify compatibility of wetted parts (copper alloy) with the media being measured to prevent corrosion and failure.
  • Install the gauge securely using appropriate tools. Do not overtighten the connection.
  • Protect the gauge from excessive vibration, shock, and extreme temperatures outside its operating range.
  • In case of damage or malfunction, do not attempt to repair the gauge yourself. Contact qualified personnel or WIKA support.
  • Wear appropriate personal protective equipment (PPE) when handling and installing pressure gauges, especially when dealing with pressurized systems.

4. Opsætning og installation

Proper installation is crucial for accurate readings and longevity of the pressure gauge.

  1. Udpakning: Carefully remove the pressure gauge from its packaging. Inspect for any visible damage.
  2. Forbindelsestype: This model features a 1/4" Male NPT Bottom Mount connection. Ensure your system has a compatible female NPT port.
  3. Gevindtætningsmiddel: Apply a suitable thread sealant (e.g., PTFE tape or pipe dope) to the male NPT threads of the gauge. Ensure the sealant does not enter the gauge's inlet.
  4. Montering: Screw the gauge into the female NPT port. Use a wrench on the hex flats of the connection. Gør ikke use the gauge case or bezel to tighten, as this can damage the internal mechanism.
  5. Orientering: Orient the gauge so the dial is easily readable.
  6. Systemtryk: Slowly pressurize the system after installation, checking for any leaks at the connection point.

5. Betjeningsvejledning

The WIKA 9767070 pressure gauge provides a direct reading of system pressure.

  • Reading the Dial: The gauge displays pressure in pounds per square inch (psi). The needle indicates the current pressure against the graduated scale.
  • Trykområde: This specific model has a range of 0-160 psi. Ensure the operating pressure of your system remains within this range.
  • Overtryksbeskyttelse: While the gauge is designed for its specified range, continuous operation at or near the maximum pressure is not recommended for optimal lifespan. Avoid sudden pressure spikes beyond the gauge's maximum rating.
  • Liquid Filling: This is a liquid/refillable gauge. The liquid (typically glycerin or silicone) dampens pulsations and vibrations, protecting the internal mechanism and improving readability. The liquid level should be maintained as per manufacturer guidelines.

6. Vedligeholdelse

Regular maintenance ensures the accuracy and longevity of your pressure gauge.

  • Rensning: Clean the exterior of the gauge with a soft, damp cloth. Do not use abrasive cleaners or solvents that could damage the casing eller vælg.
  • Inspektion: Periodically inspect the gauge for any signs of damage, such as cracks in the casing, bent needle, or leaks at the connection.
  • Liquid Level Check: For liquid-filled gauges, periodically check the liquid level. If the liquid level is significantly low or if the liquid appears cloudy or discolored, it may indicate a leak or contamination. Consult WIKA for refilling procedures or service.
  • Kalibrering: Pressure gauges should be calibrated periodically by qualified personnel to ensure continued accuracy. The frequency of calibration depends on the application's requirements and industry standards.

7. Fejlfinding

Se følgende tabel for almindelige problemer og deres mulige løsninger:

ProblemMulig årsagLøsning
No pressure reading / Needle stuck at zeroNo pressure in the system; Clogged connection; Damaged internal mechanism.Verify system pressure; Check for obstructions in the connection line; If damaged, replace the gauge.
Upræcis læsningGauge out of calibration; Overpressure exposure; Temperature effects; Vibration.Recalibrate the gauge; Ensure operating within specified range; Protect from extreme temperatures/vibration.
Liquid leakage from casingSeal failure; Casing-skade.Contact WIKA support for repair or replacement. Do not attempt to seal yourself.
Needle fluctuates excessivelySystem pulsations; Low liquid fill level (for liquid-filled gauges).Install a snubber or pulsation dampener; Check and replenish liquid fill if necessary (contact WIKA).

If the problem persists after attempting these solutions, contact WIKA Instrument Corporation for further assistance.

8. Specifikationer

The following are the technical specifications for the WIKA 9767070 Industrial Pressure Gauge (Model: 9767070TCAL):

  • Mærke: WIKA
  • Modelnummer: 9767070TCAL
  • Trykområde: 0-160 psi
  • Nøjagtighed: ±2/1/2% of span (ASME Grade A)
  • Wetted Parts Material: Kobberlegering
  • Etui materiale: Rustfrit stål
  • Urskivestørrelse: 2-1/2 tommer
  • Forbindelsestype: 1/4" Male NPT Bottom Mount
  • Type: Liquid/Refillable
  • Varens vægt: 0.52 pund (ca. 8.32 ounces)
  • Fabrikant: WIKA Instrument Corporation

9. Garanti og support

WIKA Instrument Corporation manufactures high-quality measurement instruments. For specific warranty information regarding your WIKA 9767070 Industrial Pressure Gauge, please refer to the documentation included with your purchase or visit the official WIKA webwebsted.

For technical support, service, or inquiries about parts and accessories, please contact WIKA Instrument Corporation directly. Contact details can typically be found on their official webwebsted eller produktemballage.

Fabrikant: WIKA Instrument Corporation

Relaterede dokumenter - 9767070TCAL

Preview WIKA L981.SY Inline Diaphragm Seal - Threaded NPT Datasheet
Comprehensive datasheet for the WIKA L981.SY Threaded NPT Inline Diaphragm Seal. Details application, design, materials, pressure ranges, connection options, and ordering information for process industry use.
Preview Manómetro de Muelle Tubular WIKA Modelos 262.50, 263.50, 262.30, 263.30: Especificaciones Técnicas
Hoja técnica detallada de los manómetros WIKA con muelle tubular, modelos 262.50, 263.50, 262.30 y 263.30. Diseñados para la industria de procesos, ofrecen alta resistencia a la corrosión y seguridad en entornos agresivos.
Preview WIKA A2G-10 & A2G-15 Differential Pressure Gauges: Operating Instructions
This document provides comprehensive operating instructions for the WIKA A2G-10 and A2G-15 differential pressure gauges. These instruments are designed for monitoring differential pressure in ventilation and air-conditioning applications, utilizing state-of-the-art technology and adhering to stringent quality standards, with management systems certified to ISO 9001 and ISO 14001.
Preview WIKA Pressure Switch PSD-3x Series Operating Instructions
Operating instructions for WIKA Pressure Switch models PSD-3x, PSD-30, and PSD-31. This guide details technical specifications, safety protocols, installation, operation, and troubleshooting for industrial pressure monitoring applications.
Preview WIKA TC10-0 Industrielt Termoelement: Produkt Overview og specifikationer
Omfattende guide til WIKA TC10-0 industrielle termoelement, der beskriver dets anvendelser, funktioner, tekniske specifikationer og tilgængelige muligheder til forskellige industrielle miljøer. Indeholder information om temperaturområder, beskyttelseskapper og certificeringer.
Preview WIKA TR10-0 and TC10-0 Resistance Thermometer and Thermocouple Operating Instructions
Comprehensive operating instructions for WIKA's TR10-0 resistance thermometers and TC10-0 thermocouples, detailing installation, connection, safety, and specifications for industrial applications, including hazardous areas.