Commax TP-12RM

Brugermanual til Commax TP-12RM Master Interphone System

Models: TP-12RM (Master Unit), TP-S (Remote Unit), RF-24015S (Power Supply)

1. Introduktion

This manual provides comprehensive instructions for the installation, operation, and maintenance of your Commax TP-12RM Master Interphone System. This system facilitates communication between a central master unit and up to twelve remote units. Please read this manual thoroughly before operating the system to ensure proper function and safety.

2. Sikkerhedsoplysninger

  • Ensure all wiring is performed by a qualified professional to prevent electrical hazards.
  • Use only the provided RF-24015S DC24V power supply. Using an incorrect power supply may damage the units and void the warranty.
  • Do not expose the units to water, excessive moisture, or extreme temperatures.
  • Do not attempt to open or repair the units yourself. Refer all servicing to authorized personnel.
  • Keep the units away from strong electromagnetic fields.

3. Pakkens indhold

Bekræft at alle komponenter er til stede i pakken:

  • 1 x Commax TP-12RM Master Unit
  • 12 x Commax TP-S Remote Units
  • 1 x Commax RF-24015S DC24V Power Supply
Commax TP-12RM Master Interphone System with 12 TP-S Remote Units and RF-24015S Power Supply

Figur 1: Overview of the Commax TP-12RM Master Interphone System components. This image displays the TP-12RM master unit on the left, twelve TP-S remote units arranged in two rows on the right, and the RF-24015S power supply at the bottom left. All units are white and feature a classic interphone design with coiled handsets.

4. Opsætning og installation

4.1 Ledningsdiagram

The Commax TP-12RM system requires a 2-wire connection for each remote unit to the master unit. The power supply connects directly to the master unit. Ensure proper polarity during wiring.

Commax TP-12RM System Wiring Diagram

Figur 2: System Wiring Diagram for the Commax TP-12RM. This diagram illustrates the connection of the TP-12RM master unit (represented by a central circuit board with terminals) to multiple TP-S remote units (shown as handsets). Each TP-S unit connects to the master unit via two wires. The DC24V power supply is shown connected to the master unit, providing power to the entire system.

4.2 Installationstrin

  1. Montering: The master unit (TP-12RM) can be wall or desktop surface mounted. The remote units (TP-S) are surface mounted. Choose appropriate locations for optimal communication and accessibility.
  2. Ledningsføring: Connect each TP-S remote unit to the TP-12RM master unit using a 2-wire cable. Ensure secure connections at all terminals. The maximum transmission distance is up to 1000 meters (3000 feet) with Ø0.65mm wire.
  3. Strømforsyningsforbindelse: Connect the RF-24015S DC24V power supply to the designated power input terminals on the TP-12RM master unit.
  4. Tænd: Plug the power supply into a standard AC outlet (AC100V-240V, 50/60Hz). The system will power on.

5. Betjeningsvejledning

5.1 Making a Call (Master to Remote)

  1. Lift the handset on the TP-12RM master unit.
  2. Press the button corresponding to the desired remote unit (1-12).
  3. An electric call tone will sound at the remote unit.
  4. When the remote unit lifts its handset, communication can begin.

5.2 Making a Call (Remote to Master)

  1. Lift the handset on the TP-S remote unit.
  2. A melody sound will be heard at the TP-12RM master unit.
  3. The LED indicator on the master unit corresponding to the calling remote unit will illuminate.
  4. The master unit operator lifts the handset to establish communication.

5.3 Kommunikation

Once a call is established, speak clearly into the handset. The system supports two-way communication between the master unit and one remote unit at a time. Remote units cannot communicate directly with each other.

6. Vedligeholdelse

  • Rensning: Tør enhederne af med en blød, tør klud. Brug ikke slibende rengøringsmidler eller opløsningsmidler.
  • Inspektion: Periodically check all wiring connections for security and signs of wear.
  • Miljø: Ensure the units are kept in a clean, dry environment within the specified operating temperature range (0°C ~ 40°C / 32°F ~ 104°F).

7. Fejlfinding

If you encounter issues with your Commax interphone system, refer to the following common problems and solutions:

  • Ingen strøm:
    • Check if the power supply is securely plugged into a working outlet.
    • Verify the power supply connection to the master unit.
  • Ingen kommunikation:
    • Ensure all wiring connections between the master and remote units are secure and correctly polarized.
    • Check if the correct remote unit button is pressed on the master unit.
    • Confirm both handsets are lifted during a call.
  • Dårlig lydkvalitet:
    • Inspect wiring for damage or loose connections.
    • Ensure the transmission distance does not exceed 1000 meters with the recommended wire gauge.
  • Remote Unit Not Ringing:
    • Verify the wiring to that specific remote unit.
    • Ensure the master unit is powered on and functioning.

Hvis problemerne fortsætter, kontakt kundesupport for at få hjælp.

8. Specifikationer

Detailed specifications for the Commax TP-12RM Master Unit, TP-S Remote Unit, and RF-24015S Power Supply are provided below:

Commax Interphone System Specifications Table

Figur 3: Detailed specifications for the Commax TP-12RM Master Unit, TP-S Remote Unit, and RF-24015S Power Supply. This image presents a table format outlining key technical details such as model numbers, power sources, mounting types, wiring requirements, operating temperatures, dimensions, transmission distances, and call tone types for each component of the interphone system.

Commax Interphone System Specifications
FeatureTP-12RM (Master Unit)TP-S (Remote Unit)RF-24015S (Power Supply)
ModelnummerTP-12RMTP-SRF-24015S
StrømkildeDC24V, 1.5A (from RF-24015S)DC24V (from TP-12RM)AC100V-240V 50/60Hz Input, DC24V 1.5Amp Produktion
MonteringstypeWall or Desktop Surface MountedOverflademonteretOverflademontering
Driftstemperatur0°C ~ 40°C (32°F ~ 104°F)
Ledningsføring2 wires per substationN/A
TransmissionsafstandUp to 1000 meters / 3000 feet (Ø0.65mm wire)N/A
Dimensioner (mm)116 x 208 x 6772 x 215 x 38N/A
Ring ToneElectric call tone (to sub-unit), Melody sound (from sub-unit)Electric call tone (from master), Melody sound (to master)N/A
ForbindelseSupports up to 12 units of TP-S (Sub-unit)Connects to TP-12RM Master UnitN/A
StiktypeN/AN/AUS Type A, 2-blades prong

9. Garanti og support

Commax products are designed for reliability and performance. For warranty information, please refer to the warranty card included with your purchase or contact your authorized Commax dealer. For technical support or service inquiries, please contact Commax customer service through their official webwebstedet eller de kontaktoplysninger, der blev angivet ved køb.

Relaterede dokumenter - TP-12RM

Preview COMMAX CCU-204AGF Konverterenhed Brugermanual
Brugermanual til COMMAX CCU-204AGF-konverterenheden, der beskriver dens funktioner, installation og specifikationer. Indeholder sikkerhedsadvarsler og driftsvejledning.
Preview COMMAX CCU-208AGF Konverterenhed Brugermanual
Brugermanual til COMMAX CCU-208AGF-konverterenheden, der beskriver funktioner, advarsler, brugsanvisninger, systemdiagrammer, ledningsføring, forholdsregler og specifikationer.
Preview COMMAX dørtelefon DP-4VHP brugermanual og sikkerhedsvejledning
Omfattende brugermanual til COMMAX DP-4VHP dørtelefonen, der dækker installation, betjening, sikkerhedsforanstaltninger, specifikationer og kontaktoplysninger. Indeholder tydelige instruktioner og advarsler.
Preview Katalog Wideodomofonów og Systemów Bezpieczeństwa COMMAX
Poznaj pełną ofertę wideodomofonów, domofonów og systemów bezpieczeństwa Smart Home marki COMMAX. Katalog zawiera szczegółowe opisy produktów, specyfikacje techniczne i rozwiązania dla domu i firma.
Preview Sådan bruger du Commax CDV-70QT videodørtelefonen: En simpel manual
En kortfattet vejledning i tilslutning og brug af Commax CDV-70QT videodørtelefonen med din smartphone, inklusive funktioner som besøgsopkald, bevægelsesdetektion og sikkerhedsindstillinger.
Preview COMMAX NURESCALL SYSTEM JNS-4CM Brugermanual
Omfattende brugermanual til COMMAX NURESCALL SYSTEM JNS-4CM, der beskriver systemets introduktion, specifikationer, funktioner, betjening, programmering og installationsprocedurer.