1. Introduktion

This manual provides essential information for the safe and effective installation, operation, and maintenance of the Allanson Industrial Gas Ignitor, Model 2260-TP. This electronic ignition transformer is designed for industrial gas applications, providing reliable ignition for various heating systems.

Allanson Industrial Gas Ignitor Model 2260-TP

Figur 1: Allanson Industrial Gas Ignitor Model 2260-TP. This image displays the black rectangular electronic ignition transformer with a white label. The label clearly shows 'Allanson ELECTRONIC IGNITION TRANSFORMER CAT No. 2260-TP', along with primary and secondary voltage/current ratings. It also indicates 'MADE IN CANADA'. Electrical wires are visible, connected to one side of the unit.

2. Sikkerhedsoplysninger

ADVARSEL: Installation and servicing of this ignitor must be performed by a qualified and licensed professional. Failure to follow these instructions could result in property damage, personal injury, or death.

3. Produktet er slutview

The Allanson 2260-TP is an electronic ignition transformer designed to provide a high-voltage spark for igniting gas in industrial heating systems. It converts standard line voltage to a high-voltage output, ensuring reliable and efficient ignition.

Nøglefunktioner:

4. Opsætning og installation

Før du begynder:

  1. Ensure the power supply matches the ignitor's specifications (120V, 50/60Hz).
  2. Confirm the ignitor is compatible with your specific heating system.
  3. Gather necessary tools: screwdrivers, wire strippers, multimeter, mounting hardware.

Installationstrin:

  1. Strømafbrydelse: Turn off all power to the heating system at the main circuit breaker. Verify power is off using a multimeter.
  2. Remove Old Ignitor (if applicable): Carefully disconnect wiring and mounting hardware from the existing ignitor. Note wire connections for reference.
  3. Montering: Securely mount the Allanson 2260-TP ignitor in the designated location using appropriate hardware. Ensure it is stable and free from vibration.
  4. Ledningsføring: Connect the primary (input) wires to the 120V AC power supply according to the wiring diagram of your appliance. Connect the secondary (output) wires to the spark electrode or ignition rod. Ensure all connections are tight and insulated. Refer to the label on the ignitor for specific primary and secondary connections.
  5. Jording: Ensure the ignitor and the appliance are properly grounded.
  6. Afsluttende kontrol: Double-check all wiring connections. Ensure no loose wires or potential short circuits.

5. Betjeningsvejledning

The Allanson 2260-TP ignitor operates automatically as part of the heating system's control sequence. Once properly installed and wired, it will generate a high-voltage spark when called upon by the system's control board to ignite the gas burner.

At operere:

  1. Ensure all installation steps are completed and verified.
  2. Genopret strømmen til varmesystemet.
  3. Initiate a call for heat from the thermostat or control system.
  4. Observe the ignitor's operation. It should produce a visible spark at the electrode, leading to gas ignition.
  5. If ignition does not occur, refer to the Troubleshooting section.

6. Vedligeholdelse

The Allanson 2260-TP ignitor is designed for long-term reliability with minimal maintenance. However, periodic inspection of the entire ignition system is recommended as part of routine appliance servicing.

7. Fejlfinding

If the ignitor is not functioning correctly, perform the following checks. Always disconnect power before inspecting components.

Problem Mulig årsag Løsning
No Spark from Ignitor
  • Ingen strøm til tænding.
  • Fejlbehæftet ledningsforbindelse.
  • Defekt tænder.
  • Defekt styrekort.
  • Kontroller afbryderen og strømforsyningen.
  • Kontroller, at alle ledningsforbindelser er sikre.
  • Test ignitor for proper voltage output (requires specialized equipment and knowledge).
  • Consult appliance manual for control board diagnostics.
Intermittent Spark/Ignition
  • Løse ledningsforbindelser.
  • Dirty or worn spark electrode.
  • Fluktuerende strømforsyning.
  • Spænd alle elektriske forbindelser.
  • Clean or replace the spark electrode.
  • Have an electrician check the power supply.
Ignitor Sparks but No Gas Ignition
  • Ingen gasforsyning.
  • Defekt gasventil.
  • Blocked burner orifice.
  • Forkert gnistgab.
  • Check gas supply to the appliance.
  • Test gas valve operation.
  • Clean burner orifices.
  • Adjust spark gap according to appliance specifications.

If problems persist after troubleshooting, contact a qualified HVAC technician or the manufacturer for assistance.

8. Specifikationer

Attribut Værdi
Fabrikant Allanson
Varenummer 2260-TP
Varens vægt 7 pund
Vare Pakke Antal 1
Primær bindtage/Strøm 120V 50/60Hz 0.6A
Sekundær bindtage/Strøm 15.6 kVpk 28 mA
Dato først tilgængelig 18. august 2017

9. Garanti og support

Specific warranty information for the Allanson Industrial Gas Ignitor #2260-TP is not provided in this manual. For details regarding warranty coverage, terms, and conditions, please refer to the documentation included with your purchase or contact Allanson directly through their official webwebsted eller kundeservicekanaler.

For technical support or further assistance, please reach out to a qualified HVAC professional or the manufacturer's support team.

Relaterede dokumenter - 2260-TP

Preview Allanson 2260 Series Electronic Ignitors Instruction Manual
Comprehensive instruction manual for Allanson 2260 series electronic ignitors (models 2260-TP, 2260-TPLP, 2260-TW, 2260-TWLP, 2260-P, 2260-TPLPJB). Includes installation, maintenance, testing, and mechanical specifications for commercial and industrial gas applications.
Preview Allanson OMNI Electronic Ignitor Type 2275U Instruction Manual
Instruction manual for the Allanson OMNI Electronic Ignitor, Type 2275U, providing application details, specifications, installation, maintenance, and testing procedures for reliable ignition in gas and oil systems.
Preview Allanson OMNI 2270U-3ST Electronic Ignitor Specification Guide
Detailed specification guide for the Allanson OMNI 2270U-3ST universal electronic ignitor, featuring a built-in 3-second timer and diagnostic tool for oil burner systems. Includes technical specifications, dimensions, and contact information.
Preview Allanson 2270U-3ST OMNI Universal Electronic Ignitor Specification Guide
Detailed specification guide for the Allanson 2270U-3ST OMNI Universal Electronic Ignitor, featuring a built-in 3-second timer and diagnostic capabilities for oil burner systems.
Preview Allanson industrielle gastransformere: Specifikationer og krydsreferencevejledning
Detaljerede specifikationer og krydsreferencediagrammer for Allanson Industrial Gas Transformers, der dækker modeller som 1092-H, 1092-PF-G og andre, med kompatibilitetsoplysninger for forskellige brænderproducenter.
Preview Allanson ACL-SC-DMX DMX Sub-Controller Installation Manual
This installation manual provides detailed instructions for the Allanson ACL-SC-DMX DMX Sub-Controller, covering specifications, port configurations, wiring diagrams, and important safety precautions for RGBW lighting systems.