Defiant DW8938ABZ-B

Defiant 1-Light Integrated LED Outdoor Bronze Dusk to Dawn Security Flood Light User Manual

Model: DW8938ABZ-B

Indledning

This manual provides detailed instructions for the installation, operation, and maintenance of your Defiant 1-Light Integrated LED Outdoor Bronze Dusk to Dawn Security Flood Light. This high-performance, low-maintenance lighting solution is designed for dependable area and security illumination. Please read all instructions carefully before installation and use to ensure proper function and safety.

Sikkerhedsoplysninger

Always observe basic safety precautions when installing or using electrical products to reduce the risk of fire, electric shock, and personal injury.

  • ADVARSEL: Risiko for elektrisk stød. Afbryd strømmen til sikringen eller strømafbryderen før installation eller servicering.
  • Dette produkt skal installeres i overensstemmelse med den gældende installationskode af en person, der er bekendt med produktets konstruktion og drift og de involverede farer.
  • Use only UL listed wire connectors.
  • Installer ikke i nærheden af ​​brændbare materialer.
  • Sørg for, at alle forbindelser er sikre og korrekt isolerede.
  • Do not attempt to modify the integrated LED light source. It is not replaceable.

Pakkens indhold

Kontroller, at alle komponenter er til stede, før installationen påbegyndes.

  • Defiant 1-Light Integrated LED Outdoor Bronze Dusk to Dawn Security Flood Light Fixture
  • Monteringsudstyr (skruer, trådmøtrikker, pakning)
  • Fjernbetjening
  • Instruktionsmanual

Installation

This flood light is suitable for wall or ceiling/eaves mounting. Professional installation is recommended for electrical wiring.

Nødvendige værktøjer (ikke inkluderet):

  • Skruetrækker
  • Trådstrippere
  • Tang
  • Elektrisk tape
  • Sikkerhedsbriller

Monteringstrin:

  1. Sluk for strømmen: Locate the circuit breaker or fuse box and turn off the power to the area where you will be installing the light fixture.
  2. Forbered monteringsoverfladen: Sørg for, at monteringsfladen er ren, tør og strukturelt sund.
  3. Attach mounting plate: Secure the mounting plate to the junction box using the provided screws. Ensure the gasket is properly seated to prevent moisture entry.
  4. Ledningsforbindelser: Connect the electrical wires according to local electrical codes. Typically, connect the black wire from the fixture to the black (hot) wire from the supply, the white wire from the fixture to the white (neutral) wire from the supply, and the green or bare copper wire from the fixture to the ground wire from the supply. Use wire nuts to secure connections.
  5. Monter armaturet: Carefully align the fixture with the mounting plate and secure it with the provided screws. Ensure a tight seal against the mounting surface.
  6. Genopret strøm: Når installationen er færdig, og alle forbindelser er sikre, skal strømmen genoprettes ved afbryderen.
Defiant 1-Light Integrated LED Outdoor Bronze Dusk to Dawn Security Flood Light
Image: Defiant 1-Light Integrated LED Outdoor Bronze Dusk to Dawn Security Flood Light. This image shows the flood light in a bronze finish, featuring a single integrated LED light panel and a circular mounting base, designed for outdoor security lighting.

Betjeningsvejledning

Funktionalitet fra skumring til daggry:

The Defiant Flood Light is equipped with a built-in photocell sensor that automatically turns the light ON at dusk and OFF at dawn. This feature provides continuous security lighting without manual intervention.

  • Ensure the photocell sensor is not obstructed by objects, eaves, or other light sources, as this can interfere with its proper operation.
  • The light will activate when ambient light levels drop below a certain threshold and deactivate when light levels rise.

Betjening af fjernbetjening:

Use the included remote control for additional functionality, such as overriding the dusk-to-dawn sensor or adjusting settings if available. Refer to the remote control's specific instructions for detailed usage.

  • Point the remote control directly at the light fixture for optimal response.
  • Ensure the remote control batteries are installed correctly and are not depleted.

Opretholdelse

The Defiant LED Flood Light requires minimal maintenance due to its integrated LED design and durable construction.

  • Rensning: Rengør armaturet regelmæssigt med en blød, tør klud.amp klud til at fjerne snavs og rester. Brug ikke slibende rengøringsmidler eller opløsningsmidler.
  • Inspektion: Annually inspect the fixture for any signs of damage, loose wiring, or corrosion. Address any issues promptly.
  • LED levetid: The integrated LED has a long lifespan of approximately 50,000 hours and does not require bulb replacement.

Fejlfinding

If your flood light is not functioning as expected, refer to the following common issues and solutions:

ProblemMulig årsagLøsning
Lyset tændes ikke i skumringen.1. Strømmen er slukket.
2. Photocell obstructed or receiving too much light.
3. Defekt ledningsføring.
1. Kontroller afbryderen/sikringen.
2. Clear obstructions from photocell. Relocate if necessary to an area with less ambient light.
3. Verify all wiring connections are secure. Consult an electrician if unsure.
Lyset forbliver tændt i løbet af dagen.1. Photocell obstructed or faulty.
2. Light from another source (e.g., street light) is activating the sensor.
1. Clear obstructions from photocell. Ensure it is clean. If issue persists, photocell may be faulty.
2. Reposition the fixture or shield the photocell from external light sources.
Lyset flimrer eller dæmpes.1. Løs ledningsforbindelse.
2. Effektudsving.
3. Integrated LED issue.
1. Check and secure all wiring connections.
2. Consult an electrician to check power supply.
3. If integrated LED is faulty, the unit may need replacement.
Fjernbetjening virker ikke.1. Døde batterier.
2. Obstruction between remote and fixture.
3. Remote not paired (if applicable).
1. Udskift batterier.
2. Ensure clear line of sight to the fixture.
3. Refer to remote control instructions for pairing process.

Specifikationer

FeatureSpecifikation
Mærketrodsig
ModelnummerDW8938ABZ-B
LyskildetypeIntegreret LED
Wattage125 watt
Lysstyrke1800 lumen
Voltage120 volt (DC)
FarveBronze
MaterialeBronze
Indendørs/Udendørs brugUdendørs
Speciel funktionSkumring til daggry
KontrolmetodeApp, fjernbetjening
MonteringstypeLoftmontering, Vægmontering
EffektivitetEnergy Star Certified, 50,000 hour lamp liv
Varens vægt3.93 pund
Produktdimensioner8.4 x 7.2 x 7.9 tommer
UPC008938104784

Relaterede dokumenter - DW8938ABZ-B

Preview Defiant DFI-5886-WH Troubleshooting Guide
Troubleshooting guide for the Defiant 270° White Motion Activated Outdoor Integrated LED Triple Head Flood Light with Adjustable Color Temperature (Model DFI-5886-WH).
Preview Defiant Home Power Photocell Dusk to Dawn Remote Timer NOA0039T - Installation & Operation Guide
Learn how to install and operate the Defiant Home Power Photocell Dusk to Dawn Remote Timer (Model NOA0039T) for convenient outdoor lighting control. Includes setup, troubleshooting, and safety information.
Preview Ofte stillede spørgsmål: LED-bevægelsessikkerhedslys
Omfattende ofte stillede spørgsmål om Defiant LED-bevægelsessikkerhedslys, herunder justering af følsomhed, pærekompatibilitet, montering, områdedækning, lysniveauindstillinger (HI/LO, Dusk to Dawn, Timer), manuel tilstand, krav til samledåser og ledningsføring.
Preview Defiant NOA0039R Outdoor Timer with Wireless Remote User Manual
Instructions and specifications for the Defiant NOA0039R outdoor timer with wireless remote, featuring dusk-to-dawn and timed settings. Includes installation, troubleshooting, and safety information.
Preview Defiant Motion solcelledrevet sikkerhedslys – hurtigstartguide
En kortfattet vejledning til installation og betjening af Defiant DFI-7004-WH-G bevægelses-solcellesikringslampen, inklusive opsætning, justeringer og fejlfinding.
Preview Brugs- og vedligeholdelsesvejledning til Defiant Motion Security Light
Comprehensive guide for the Defiant Motion Security Light (models DFI-5852-BK, DFI-5852-WH), covering installation, operation, care, and troubleshooting.