PeakTech 4095

PeakTech 4095 Grafisk True RMS Bordmultimeter Brugermanual

Model: 4095

1. Introduktion

The PeakTech 4095 is a high-precision graphical True RMS bench multimeter designed for accurate electrical measurements in professional and hobbyist settings. This device features a 4-inch TFT color display, offering clear visualization of measurement data, including graphical trends. It supports a wide range of functions, including voltage, current, resistance, capacitance, frequency, and temperature measurements up to 1000 °C. With LAN, USB, and RS-232 interfaces, the PeakTech 4095 facilitates data logging and remote control, making it a versatile tool for various applications.

2. Sikkerhedsoplysninger

Please read all safety instructions carefully before operating the device.

  • Always adhere to local and national safety regulations.
  • This device is rated for CAT III 300V. Do not exceed the specified voltage and current limits for any input terminal.
  • Ensure the multimeter is properly grounded before use, especially when connecting to mains power.
  • Do not operate the device if it appears damaged or if the insulation is compromised.
  • Use only the test leads and accessories supplied or recommended by PeakTech.
  • Before changing functions or ranges, disconnect the test leads from the circuit under test.
  • Udvis ekstrem forsigtighed, når du arbejder med voltagover 30V AC RMS, 42V peak eller 60V DC, da disse udgør en risiko for stød.
  • Fuses must be replaced only with the specified type and rating (ceramic fuse).

3. Pakkens indhold

Kontroller, at alle genstande er til stede og ubeskadigede ved udpakning:

  • PeakTech 4095 Bench Multimeter
  • Testledninger
  • Type K Thermocouple Wire Sensor
  • Strømledning
  • USB kabel
  • Brugervejledning (dette dokument)
  • Software CD (for DMM Tool and drivers)

4. Produktet er slutview

4.1 Frontpanel

PeakTech 4095 Bench Multimeter Front View

Figur 1: Forside view of the PeakTech 4095 Bench Multimeter, showing the 4-inch TFT display, function buttons, navigation controls, and input terminals.

The front panel features the 4-inch TFT color display, which shows measurement values, graphs, and menu options. To the right of the display are the primary function buttons (Save, Record, Math, Utility, Port, Run/Stop) and navigation controls (Range, up/down/left/right arrows, Enter). Below the display are additional function buttons (Graph, Dual, V=, A=, Ω, Freq, Temp). On the far right are the input terminals for various measurements: HI/LO for voltage and resistance, 10A RMS for high current, and mA/µA for low current measurements. A USB host port is also located on the front for data storage.

4.2 Bagpanel

PeakTech 4095 Bench Multimeter Rear View

Figur 2: Bagside view of the PeakTech 4095 Bench Multimeter, showing power input, LAN, USB, RS-232, and external trigger ports.

The rear panel includes the main power input socket, a line selector switch (110V/220V), LAN port for network connectivity, USB device port for PC connection, RS-232 serial port, and external trigger/AUX output ports. Ensure the line selector is set correctly for your region's mains voltage before connecting power.

5. Opsætning

5.1 Strømtilslutning

  1. Before connecting the power cord, verify that the voltage selector switch on the rear panel is set to the correct mains voltage for your region (110V or 220V).
  2. Connect the supplied power cord to the power input socket on the rear panel of the multimeter.
  3. Sæt den anden ende af netledningen i en jordet stikkontakt.
  4. Press the power button on the front panel to turn on the device. The TFT display will illuminate, and the device will perform a self-test.

5.2 Indledende konfiguration

Upon first power-on or after a factory reset, you may need to configure basic settings such as language, date, and time. Navigate through the 'Utility' menu using the front panel buttons to adjust these settings.

6. Betjeningsvejledning

The PeakTech 4095 offers various measurement functions accessible via the front panel buttons. Always ensure test leads are connected to the correct input terminals for the desired measurement type.

6.1 Grundlæggende målinger

  • Voltage (V= / V~): Connect test leads to the HI and LO input terminals. Press the 'V=' button for DC voltage or 'V~' (often combined with V= or selected via a sub-menu) for AC voltage. The device supports True RMS measurements up to 100 kHz.
  • Current (A= / A~): For current measurements, connect the test leads in series with the circuit. Use the 10A RMS input for high currents or mA/µA for lower currents. Select 'A=' for DC current or 'A~' for AC current.
  • Modstand (Ω): Connect test leads to the HI and LO input terminals. Press the 'Ω' button. The device features a fast response time for resistance and continuity tests.
  • Kontinuitetstest: Select the resistance function and look for the continuity symbol. An audible tone indicates continuity.
  • Diode test: Select the diode test function (often combined with resistance). Connect the test leads to the diode to measure its forward voltage drop.
  • Frequency (Freq): Connect the signal source to the HI and LO terminals. Press the 'Freq' button to measure the frequency of an AC signal.
  • Temperatur (Temp): Connect the Type K thermocouple wire sensor to the dedicated temperature input terminals (if available, or via adapter to HI/LO). Press the 'Temp' button. The device can measure temperatures up to 1000 °C (1372 °C maximum specified).

6.2 Graphical Display and Data Logging

The 4-inch TFT display allows for graphical representation of measurements, such as voltage trends over time. Use the 'Graph' button to switch to graphical mode. The 'Record' button initiates data logging, storing measurement points to internal memory or an external USB drive connected to the front panel port. The device can store up to 1 million measurement points.

PeakTech 4095 Graphical Display Trend View

Figure 3: Graphical display showing a trend of voltage measurements over time.

6.3 avancerede funktioner

  • Matematiske funktioner: The 'Math' button provides access to various mathematical operations on measurement data, such as MIN/MAX, AVG, dB, dBm.
  • Utility Menu: The 'Utility' button allows access to system settings, calibration, display options, and interface configurations.
  • Dobbelt skærm: The 'Dual' button enables simultaneous display of two different measurement parameters or a primary measurement with a secondary parameter (e.g., AC voltage og frekvens).

7. Forbindelse

The PeakTech 4095 offers multiple interfaces for data transfer and remote control.

  • USB-grænseflade: Connect the multimeter to a PC using the USB device port on the rear panel. This allows for data transfer and remote control via software. The front panel USB host port is for connecting USB storage devices for data logging.
  • LAN-interface: Connect the multimeter to a network using an Ethernet cable. This enables remote control and data access over a local area network.
  • RS-232 grænseflade: The serial RS-232 port on the rear panel provides another option for connecting the multimeter to a PC or other control systems.

For PC connectivity, install the 'DMM Tool' software and drivers from the supplied CD or PeakTech's website. While the software is designed for data acquisition and control, users have reported that specific versions may not be fully updated for the 4095 model's advanced features, particularly for direct PC control and processing of .csv recordings. For detailed instructions on using the software, refer to the software's documentation.

8. Vedligeholdelse

8.1 Rengøring

For at rengøre enheden skal du bruge en blød, damp cloth with a mild detergent. Do not use abrasive cleaners or solvents. Ensure the device is powered off and disconnected from all power sources and circuits before cleaning.

8.2 Udskiftning af sikringer

If the current measurement function fails, the fuse may need replacement. Refer to the specifications for the correct ceramic fuse type and rating. Fuse replacement should only be performed by qualified personnel. Disconnect the device from all power sources and test leads before attempting to open the casing.

8.3 Kalibrering

The PeakTech 4095 is factory calibrated. For continued accuracy, periodic calibration by an authorized service center is recommended. Refer to the 'Utility' menu for calibration information.

9. Fejlfinding

  • Enheden tændes ikke: Check the power cord connection and ensure the power outlet is functional. Verify the rear panel voltage selector switch is set correctly (110V/220V).
  • Ingen aflæsning eller 'OL' vises: Ensure test leads are correctly connected to the appropriate input terminals and the circuit under test. Check if the measurement range is appropriate for the expected value; try a higher range if 'OL' (Overload) is displayed.
  • Incorrect current reading: Check the fuse. Ensure the test leads are connected to the correct current input (10A or mA/µA) and in series with the circuit.
  • Connectivity issues (LAN/USB/RS-232): Verify cable connections. Ensure correct drivers are installed on the PC. Check network settings for LAN connectivity.
  • Problemer med skærm: If the display is dim or flickering, check power supply. If specific segments are missing, contact support.

10. Specifikationer

ParameterVærdi
Modelnummer4095
Vise4-inch TFT Color Display, 60,000 Counts
MåletypeÆgte RMS multimeter
AC båndbreddeOp til 100 kHz
Datalogning1 Million Measurement Points
GrænsefladerLAN, USB (Device & Host), RS-232
SikkerhedsvurderingCAT III 300V, TÜV/GS, EN-61010-1
SikringstypeCeramic Fuse
TemperaturmålingUp to 1372 °C (Type K Thermocouple)
StrømkildeMains Powered (110V/220V selectable)
Produktmål (L x B x H)30 x 24 x 11 cm
Varens vægt3 kg
FabrikantPeakTech
OprindelseslandKina

11. Garanti og support

PeakTech products are manufactured with quality and reliability in mind. For warranty information, please refer to the warranty card included with your product or visit the official PeakTech website. In case of technical issues, questions, or service requests, please contact PeakTech customer support or your local distributor. Ensure you have your product model number (4095) and purchase details available when seeking support.

Relaterede dokumenter - 4095

Preview PeakTech 1072/1073 Smart Digital Multimeter Operation Manual
Comprehensive operation manual for the PeakTech 1072 and 1073 smart digital multimeters, detailing features, safety instructions, and usage guidelines.
Preview PeakTech 2510 Power Analyzer brugervejledning
Omfattende brugermanual til PeakTech 2510 Power Analyzer, med detaljerede oplysninger om dens funktioner, specifikationer, sikkerhedsforanstaltninger og driftsprocedurer for elektriske målinger.
Preview PeakTech 1072/1073 Smart Digital-Multimeter Bedienungsanleitung
Umfassende Bedienungsanleitung for PeakTech 1072 og 1073 Smart Digital-Multimeter. Erfahren Sie mehr über Funktionen, Sicherheitshinweise, Messmodi og tekniske Spezifikationen für präzise elektrische Messungen.
Preview PeakTech 3441/3442 digitalt multimeter brugermanual
Omfattende betjeningsmanual til PeakTech 3441 og 3442 digitale multimetre. Detaljer om sikkerhed, betjening, funktioner som True RMS og Bluetooth (3442) samt tekniske specifikationer.
Preview PeakTech 2510 Power Analyzer brugervejledning
Brugermanual til PeakTech 2510 Power Analyzer, med detaljerede oplysninger om funktioner, tekniske specifikationer, sikkerhedsinstruktioner og driftsprocedurer.
Preview PeakTech 3432 Sikringsfinder Brugermanual
Brugermanual til PeakTech 3432 sikringsfinder, en enhed til at finde sikringer i elektriske kredsløb. Indeholder sikkerhedsinstruktioner, driftsprincipper og tekniske specifikationer.