Lutron LECL-153PH-LA

Lutron LECL-153PH-LA X-10 Kompatibel Lysdæmper Brugermanual

Model: LECL-153PH-LA

Indledning

This manual provides detailed instructions for the safe installation, operation, and maintenance of your Lutron LECL-153PH-LA X-10 Compatible Dimmer Switch. This device is designed to control incandescent, halogen, and certain fluorescent lighting loads up to 600 watts at 120 Volts, utilizing X-10 powerline communication for dimming and switching functions. Please read all instructions thoroughly before proceeding with installation or use.

Vigtige sikkerhedsoplysninger

Pakkens indhold

Lutron LECL-153PH-LA X-10 Compatible Dimmer Switch in Light Almond

Billede: Forside view of the Lutron LECL-153PH-LA X-10 Compatible Dimmer Switch in Light Almond color, showing the rocker switch and slide dimmer control.

Specifikationer

ModelnummerLECL-153PH-LA
MærkeLutron
DriftstilstandManual, X-10 Control
Nuværende vurdering5 Amps
Operation Voltage120 Volt AC, 60 Hz
Wattage (maks.)600 Watts (Incandescent/Halogen), consult Lutron for fluorescent compatibility
KredsløbstypeEnkeltpolet eller 3-vejs
Aktuator typeRocker (On/Off), Slide (Dimming)
KontaktmaterialeDurable Engineered Thermoplastic
ForbindelsesprotokolX-10
FarveLys mandel
Dimensioner (L x B x H)3 x 0.3 x 4.8 tommer
Varens vægt3.94 ounce
International Protection RatingIP00

Installation (Opsætning)

This dimmer is an X-10 compatible device. Proper installation requires understanding of both standard electrical wiring and X-10 addressing. If you are unfamiliar with X-10 systems, please consult an X-10 expert or a qualified electrician.

Nødvendige værktøjer:

Ledningsinstruktioner:

  1. Sluk for strømmen: Locate the circuit breaker or fuse that controls the light switch you are replacing. Turn it OFF. Verify power is off at the switch box using a voltage tester.
  2. Fjern eksisterende switch: Fjern forsigtigt vægpladen, og skru den eksisterende afbryder af vægdåsen. Frakobl ledningerne fra den gamle afbryder.
  3. Identificér ledninger:
    • Line/Hot Wire: Fører strøm fra afbryderen.
    • Indlæs ledning: Forbindes til lysarmaturet.
    • Neutral ledning: (If present, typically white) Not always required for dimmers, but check dimmer specifications.
    • Jordledning: (Bare copper or green) Connects to the metal electrical box or ground wire bundle.
    • Traveler Wires: (For 3-way installations, typically red or black) Connects between two switches controlling the same light.
  4. Connect the Dimmer:
    • Tilslut jordledning from the wall box to the green or bare copper wire on the dimmer.
    • Tilslut Line/Hot wire to the designated Line terminal on the dimmer.
    • Tilslut Læg ledning i to the designated Load terminal on the dimmer.
    • Ved 3-vejs installationer skal du tilslutte traveler wires to the appropriate traveler terminals on both the dimmer and the companion switch. Refer to the specific wiring diagram provided with your dimmer for 3-way configurations.
    • Ensure all wire connections are secure using wire connectors.
  5. Set X-10 Address: Before mounting, set the X-10 House Code and Unit Code on the dimmer. This is typically done via small rotary switches or dip switches on the dimmer module. Refer to the specific instructions on the dimmer itself or a separate X-10 setup guide for your system.
  6. Monter lysdæmperen: Carefully fold the wires into the wall box and secure the dimmer to the box with the provided screws.
  7. Installer vægplade: Fastgør vægpladen.
  8. Gendan strøm: Tænd for strømmen igen ved afbryderen.

Operation

The Lutron LECL-153PH-LA dimmer switch offers both manual control and X-10 powerline control.

Manuel kontrol:

X-10 Control:

Once the X-10 House Code and Unit Code are set, the dimmer will respond to X-10 commands sent over the powerline from an X-10 controller (e.g., a remote, wall-mounted keypad, or computer interface). Common X-10 commands include:

Refer to your X-10 system's documentation for specific programming and command details.

Opretholdelse

Fejlfinding

ProblemMulig årsagLøsning
Lights do not turn ON or OFF.
  • Strømmen er afbrudt ved afbryderen.
  • Løs ledningsforbindelse.
  • Bulb is burned out or incompatible.
  • Incorrect X-10 address.
  • Kontroller og nulstil afbryderen.
  • Sluk for strømmen, kontroller alle ledningsforbindelser.
  • Replace bulb with a known good, dimmable bulb.
  • Verify X-10 House and Unit Codes match your system.
Lysene flimrer eller brummer.
  • Inkompatibel pæretype.
  • Load exceeds dimmer's wattage vurdering.
  • Poor X-10 signal quality.
  • Ensure bulbs are dimmable incandescent, halogen, or compatible fluorescent.
  • Reducer det samlede watttage of connected bulbs.
  • Consider an X-10 signal amplifier or phase coupler if X-10 control is the issue.
Dimmer does not respond to X-10 commands.
  • Incorrect X-10 address.
  • Weak X-10 signal.
  • X-10 noise on powerline.
  • Double-check House and Unit Code settings.
  • Ensure X-10 transmitter is working correctly.
  • Install an X-10 filter on noisy appliances or use a phase coupler.

Garanti og support

This Lutron product is covered by a warranty. For detailed warranty information, please refer to the warranty card included with your product or visit the official Lutron website. For technical support, troubleshooting assistance, or to inquire about replacement parts, please contact Lutron customer service directly.

Lutron Webwebsted: www.lutron.com

Relaterede dokumenter - LECL-153PH-LA

Preview Lutron Diva LED+ Dimmer: Specifications, Features, and Wiring Guide
Comprehensive specifications, features, color options, and wiring diagrams for the Lutron Diva LED+ Dimmer switch, designed for dimmable LED, CFL, halogen, and incandescent bulbs.
Preview Lutron P5044-X-L Wall Mount Fixture Installation Instructions
Comprehensive installation guide for the Lutron P5044-X-L wall mount fixture, covering preparation, mounting, wiring, finishing, and LED module replacement. Includes ordering information for compatible dimmers.
Preview Lutron Maestro C.L MACL-153M Dimmer Installation Guide
Comprehensive installation guide for the Lutron Maestro C.L MACL-153M dimmer, covering single-location and multi-location wiring, setup, operation, and compatibility for LED, CFL, halogen, and incandescent bulbs. Includes safety warnings and troubleshooting tips.
Preview Lutron LED+ Dimmer Quick Install Guide RCL-153PNL
A quick installation guide for the Lutron LED+ Dimmer, model RCL-153PNL, providing step-by-step instructions for single-pole and 3-way installations, including important safety notes and dimming range adjustments.
Preview Lutron LED+ Dimmer RCL-153PNL Quick Install Guide
This guide provides quick installation instructions for the Lutron RCL-153PNL LED+ Dimmer, covering single-pole and 3-way applications, wiring, adjustments, and important safety notes.
Preview Lutron HomeWorks Maestro LED+ RF Dimmer Installation Guide
Comprehensive installation guide for the Lutron HomeWorks Maestro LED+ RF Dimmer (HQRD-PRO & HQRA-PRO). Covers wiring configurations for single, two, and three-or-more location setups, load type compatibility, dimmer operation, system setup, factory reset, and troubleshooting.