3M FT-30

3M FT-30 Respirator Kvalitativ Pasformstestsæt (Bitter Smag) Brugsanvisning

Model: FT-30

1. Introduktion

This manual provides detailed instructions for the proper use, setup, operation, and maintenance of the 3M FT-30 Respirator Qualitative Fit Test Kit, Bitter Taste. This kit is designed to qualitatively test the fit of respirators, ensuring a proper seal for user protection. It utilizes a bitter-tasting aerosol to detect leakage.

It is crucial to read and understand all instructions before using the kit to ensure accurate results and user safety. This kit is intended for professional use in accordance with occupational safety standards.

2. Kitkomponenter

The 3M FT-30 Qualitative Fit Test Kit typically includes the following components:

  • Test Hood: A clear hood designed to enclose the test subject's head and the respirator.
  • Nebulizers (2): Devices used to generate the test aerosol. One for sensitivity solution, one for fit test solution.
  • Sensitivity Solution (FT-31): A solution used to determine the test subject's ability to detect the bitter taste.
  • Fit Test Solution (FT-32): A solution containing the bitter agent used for the actual fit test.
  • Brugsanvisning: This document provides detailed guidance.
3M FT-30 Respirator Qualitative Fit Test Kit components including hood, nebulizers, and solutions.

Image 1: The 3M FT-30 Respirator Qualitative Fit Test Kit, showing the main components such as the test hood, nebulizers, and solution bottles. This visual aid helps users identify the contents of their kit.

3. Opsætning

  1. Forbered området: Select a clean, well-ventilated area free from strong odors or drafts that could interfere with the test.
  2. Assemble Nebulizers: Ensure both nebulizers are clean and properly assembled. Fill one nebulizer with the FT-31 Sensitivity Solution and the other with the FT-32 Fit Test Solution. Label them clearly to avoid confusion.
  3. Prepare Test Subject: Instruct the test subject to refrain from eating, drinking (except water), chewing gum, or smoking for at least 15 minutes prior to the test.
  4. Respirator Selection: The test subject should don the respirator they will be using, ensuring it is properly adjusted according to the manufacturer's instructions.

4. Betjeningsvejledning

4.1. Følsomhedstest

  1. Position Test Subject: Have the test subject place their head inside the test hood.
  2. Administer Sensitivity Solution: Using the nebulizer filled with FT-31 Sensitivity Solution, squeeze the bulb fully until a fine mist is produced. Administer 10 squeezes into the hood.
  3. Detect Taste: Ask the test subject if they can taste the bitter solution. If not, administer 10 more squeezes. Repeat this process, adding 10 squeezes at a time, until the subject detects the taste. Record the total number of squeezes required.
  4. No Taste Detected: If the subject cannot detect the taste after 30 squeezes, they cannot be fit tested with the bitter taste method. An alternative fit test method must be used.

4.2. Tilpasningstest

  1. Respirator Donning: The test subject should don their respirator and perform a user seal check as per the respirator manufacturer's instructions.
  2. Position Test Subject: Have the test subject place their head inside the test hood.
  3. Administer Fit Test Solution: Using the nebulizer filled with FT-32 Fit Test Solution, administer the same number of squeezes determined in the sensitivity test into the hood.
  4. Perform Exercises: While the solution is being administered, the test subject must perform a series of exercises for one minute each:
    • Normal vejrtrækning
    • Dyb vejrtrækning
    • Turning head side to side
    • Moving head up and down
    • Reading aloud or talking
    • Bending over (if applicable)
  5. Detect Taste: During each exercise, ask the test subject if they can taste the bitter solution. If they taste it at any point, the respirator has failed the fit test.
  6. Bestå ikke-bestå: If the test subject does not detect the bitter taste throughout the entire fit test procedure, the respirator has passed the qualitative fit test.
  7. Dokumentation: Record the results of the fit test, including the respirator model, date, and outcome.

5. Vedligeholdelse

  • Cleaning Nebulizers: After each use, disassemble and thoroughly clean the nebulizers with warm water and mild soap. Rinse thoroughly and allow to air dry completely before storage.
  • Cleaning Test Hood: Wipe the test hood with a damp cloth and mild disinfectant. Ensure it is dry before storage.
  • Opbevaring af opløsning: Store sensitivity and fit test solutions in a cool, dry place, away from direct sunlight. Ensure bottles are tightly capped. Check expiration dates regularly.
  • Inspektion: Periodically inspect all kit components for damage, wear, or contamination. Replace any damaged parts immediately.

6. Fejlfinding

Problem Mulig årsag Løsning
Test subject cannot taste solution during sensitivity test.
  • Insufficient solution administered.
  • Nebulizer not producing fine mist.
  • Subject has impaired sense of taste.
  • Subject ate/drank/smoked recently.
  • Administer more squeezes (up to 30).
  • Check nebulizer for clogs; clean if necessary.
  • Wait 15 minutes and re-test sensitivity. If still no taste after 30 squeezes, use an alternative fit test method.
Respirator fails fit test (subject tastes solution).
  • Improperly donned respirator.
  • Incorrect respirator size/model.
  • Facial hair or other obstructions.
  • Damaged respirator.
  • Re-don respirator and perform user seal check.
  • Try a different size or model of respirator.
  • Remove facial hair or other obstructions.
  • Inspect respirator for damage; replace if necessary.
Nebulizer not producing mist.
  • Tilstoppet dyse.
  • Insufficient solution.
  • Damaged nebulizer.
  • Clean nebulizer nozzle.
  • Ensure adequate solution in reservoir.
  • Replace nebulizer.

7. Specifikationer

  • Modelnummer: FT-30
  • Test Agent: Denatonium Benzoate (Bitter Taste)
  • Fabrikant: COLE-PARMER
  • Pakkedimensioner: 13.58 x 13.35 x 5.31 tommer
  • Pakkevægt: Cirka 1.6 ounce
  • Tiltænkt brug: Qualitative fit testing for tight-fitting respirators.

8. Vigtige sikkerhedsoplysninger

  • Always follow local, state, and federal regulations for respirator fit testing.
  • Ensure the test subject is medically cleared to wear a respirator.
  • Do not use this kit if the test subject has a known allergy to any of the solution components.
  • Avoid direct contact with the solutions. In case of contact, rinse thoroughly with water.
  • Opbevares utilgængeligt for børn.
  • Dispose of used solutions and components according to local regulations.

9. Support og yderligere information

For additional support, technical assistance, or to inquire about other 3M safety products, please refer to the official 3M website or contact your local 3M representative. Always consult the latest product literature and safety data sheets (SDS) for comprehensive information.

Fabrikant: COLE-PARMER

Mærke: 3M