1. Produktet er slutview
The Prity AW16 is a wood-burning fireplace insert designed for corner placement, featuring a water jacket for integration into a central heating system. It is equipped with heat-resistant ceramic glass, a cast iron grate, and wooden handles for safe operation. Control over air supply and flame intensity is managed via front and smoke dampers.

Image 1.1: The Prity AW16 wood stove insert with a fire burning in the combustion chamber.
2. Vigtige sikkerhedsoplysninger
Please read all safety instructions carefully before installation and operation. Failure to follow these instructions may result in property damage, injury, or death.
- Sørg altid for tilstrækkelig ventilation under drift.
- Only use approved fuel types (dry wood, wood briquettes).
- Hold børn og kæledyr væk fra komfurets varme overflader.
- Opbevar ikke brandfarlige materialer i nærheden af komfuret.
- Regularly inspect the chimney and flue for blockages or damage.
- Ensure minimum clearances to combustible materials are strictly observed:
- Bag: 400 mm
- Left and Right Sides: 400 mm
- Loft: 600 mm
- Front: 800 mm (within the entire radiation area of the glass)
- Floor: 0 mm (if non-combustible)
3. Installationsvejledning
3.1 Placering
The Prity AW16 is designed as an insert for corner installations. Ensure the chosen location can support the stove's weight and meets all safety clearance requirements.
3.2 Dimensioner og frirum
Accurate measurements are crucial for safe and effective installation.
- Total Dimensions (L x W x H): 1010 x 690 x 730 mm
- Combustion Chamber Dimensions (L x W x H): 880 x 550 x 370 mm
- Vægt: 125 kg
- Flue Pipe Diameter: 200 mm

Image 3.1: The Prity AW16 wood stove insert integrated into a corner fireplace setting in a living room.
3.3 Connection to Central Heating
This model includes a water jacket for connection to a central heating system. Professional installation by a qualified technician is highly recommended for this component to ensure proper function and safety. The water jacket volume is 34 liters.
4. Betjeningsvejledning
4.1 Brændstoftype
The Prity AW16 is designed for burning solid fuels, specifically dry wood or wood briquettes. Do not use liquid fuels, trash, or treated wood, as this can damage the stove and pose a safety hazard.
4.2 Loading Fuel
Open the main door using the wooden handle. Place dry wood or briquettes onto the cast iron grate. Avoid overfilling the combustion chamber. Close the door securely before igniting or adjusting air controls.
4.3 Luftkontrol
The stove features a front damper to control the primary air supply to the combustion chamber. Adjust this damper to regulate the intensity of the fire. For initial ignition, keep the damper fully open. Once the fire is established, you can reduce the air supply to achieve a slower burn.
4.4 Flame Intensity
En røg damper is provided to further adjust the flame intensity and control the rate at which exhaust gases leave the combustion chamber. Use this in conjunction with the front air damper to optimize burning efficiency and heat output.
5. Vedligeholdelse
5.1 Rengøring
- Askefjernelse: Regularly remove ash from the ash pan beneath the cast iron grate. Ensure the stove is completely cool before handling ash.
- Rengøring af glas: The ceramic glass can be cleaned when cool using a specialized fireplace glass cleaner or a damp cloth dipped in ash.
- Flue and Chimney: Have your flue and chimney inspected and cleaned by a qualified professional at least once a year, or more frequently depending on usage.
5.2 Eftersyn
Periodically inspect the stove for any signs of wear or damage, including:
- Cracks in the ceramic glass.
- Damage to the door seals.
- Loose or damaged components (dampers, handles).
- Corrosion or damage to the water jacket connections.
Any damaged parts should be replaced immediately by a qualified technician.
6. Fejlfinding
Dette afsnit indeholder generel vejledning til almindelige problemer. Ved komplekse problemer skal du kontakte en kvalificeret tekniker.
- Poor Draft/Smoke Backflow: Check for chimney blockages, ensure dampers are open, and verify proper chimney height and insulation.
- Lav varmeeffekt: Ensure you are using dry, seasoned wood. Check air damper settings and ensure the combustion chamber is not overfilled. Verify water jacket connections are functioning correctly if connected to central heating.
- Excessive Burn Rate: Adjust the front air damper and smoke damper to reduce air supply. Ensure door seals are intact.
7. Tekniske specifikationer
| Specifikation | Værdi |
|---|---|
| Modelnummer | AW16 |
| Mærke | Prity |
| Samlede dimensioner (L x B x H) | 1010 x 690 x 730 mm |
| Combustion Chamber Dimensions (L x W x H) | 880 x 550 x 370 mm |
| Vægt | 125 kg |
| Nominal Heating Power (Total) | 16 + 5 kW (21 kW) |
| Water Heating Output | 16 kW |
| Room Heating Output | 5 kW |
| Water Jacket Volume | 34 liter |
| Røgrørs diameter | 200 mm |
| Heated Surface Area | Ca. 119 m² |
| Varmekapacitet | Ca. 323 m³ |
| Materiale | Glass, Wood, Ceramic, Cast Iron |
| Energiklasse | A |
| Maximum Working Pressure (Water) | 1.25 bar |
| Efficiency (Nominal Heat Output) | 79.4 % |
| ASIN | B06XH1PC8T |
| Product Identifier (from image) | 3800215095108 |

Image 7.1: Energy efficiency label for the Prity AW16, showing an A rating and heat outputs.

Image 7.2: Declaration of Performance for the Prity AW16, detailing essential characteristics and compliance with EU regulations.
8. Garanti og support
Information regarding specific warranty terms and customer support contacts was not available in the provided product data. Please refer to your purchase documentation or contact the retailer for details on warranty coverage and technical assistance.