Neoteck NTK018-US

Neoteck digital pladespiller, stylus-kraftmåler (NTK018-US) brugsanvisning

Model: NTK018-US | Brand: Neoteck

Indledning

The Neoteck Digital Turntable Stylus Force Gauge is designed for precise measurement of turntable stylus tracking force. Accurate stylus force is crucial for optimal playback, minimizing record wear, and extending cartridge life. This device offers high precision with a measurement range of 0.01g to 5.00g, featuring a clear blue LCD backlight for easy reading.

Nøglefunktioner:

  • High precision measurement (0.01g to 5.00g)
  • Blue LCD backlight for clear visibility
  • Non-magnetic design, suitable for MM/MC/MI and Piezoelectric Acoustical Pickups
  • Auto shut-off function to conserve battery life
  • Compact and portable design with protective leather case

Pakkens indhold

Bekræft at alle varer er til stede i din pakke:

  • 1 x Neoteck Digital Turntable Stylus Force Gauge
  • 1 x 5g Calibration Weight
  • 3 x LR44 1.5V Lithium Cell Batteries (pre-installed or included separately)
  • 1 x Leather Protective Case
  • 1 x brugermanual
Neoteck Digital Turntable Stylus Force Gauge package contents including the gauge, calibration weight, batteries, and leather case.

Image: Contents of the Neoteck Digital Turntable Stylus Force Gauge package.

Opsætning

1. Batteriinstallation

If batteries are not pre-installed, open the battery compartment on the underside of the gauge. Insert the three LR44 1.5V Lithium Cell batteries, ensuring correct polarity. Close the compartment securely.

2. Tænd/sluk

Tryk på Magt button to turn the device on. The LCD display will illuminate. To turn off the device, press and hold the Magt button for a few seconds, or it will automatically shut off after a period of inactivity (default is 60 seconds, adjustable).

3. Zero Setting (Tare Function)

Before each measurement, ensure the gauge is placed on a stable, level surface (e.g., your turntable platter) and press the T (Tare) button. The display should show "0.00g". This calibrates the scale to disregard the weight of the platter mat or any other items on the platter.

4. Enhedskonvertering

Tryk på M (Mode) button to cycle through different measurement units (grams, ounces, etc.). For stylus force measurement, ensure the unit is set to grams (g).

Video: Demonstrates battery installation, powering on/off, zero setting, and unit conversion for the Neoteck Digital Turntable Stylus Force Scale.

Betjeningsvejledning

Measuring Stylus Tracking Force:

  1. Place the stylus force gauge on the turntable platter, ideally on the record mat, ensuring it is level.
  2. Power on the gauge and press the T (Tare) button to zero the display.
  3. Carefully lower the turntable's tonearm so that the stylus rests gently on the center of the weighing platform (the small circular area) of the gauge.
  4. Read the displayed value in grams (g). This is your current stylus tracking force.
  5. Adjust your turntable's counterweight or tracking force mechanism as needed to achieve the recommended tracking force for your cartridge. Refer to your cartridge manufacturer's specifications for the optimal range.
  6. Once the desired force is achieved, carefully lift the tonearm from the gauge.
Turntable stylus resting on the Neoteck Digital Stylus Force Gauge, displaying a measurement.

Image: A turntable stylus being measured by the Neoteck Digital Stylus Force Gauge.

Kalibrering

The stylus force gauge comes pre-calibrated. However, if you suspect inaccuracy or wish to verify its calibration, follow these steps:

  1. Remove the protective cover from the weighing platform.
  2. Turn on the gauge and wait for the display to show "0.00g".
  3. Tryk og hold på M (Mode) button for 3 seconds until "CAL" is displayed. Release the button.
  4. The display will then flash "5.00g".
  5. Carefully place the included 5g calibration weight onto the center of the weighing platform.
  6. Wait for the display to show "PASS". This indicates successful calibration. If "ERR" is displayed, the calibration failed; turn off the device and repeat the process.
  7. Remove the calibration weight. The gauge is now calibrated and ready for use.
Neoteck Digital Turntable Stylus Force Gauge with 5g calibration weight on the platform and protective cover removed.

Image: Neoteck Stylus Force Gauge with the 5g calibration weight in place.

Opretholdelse

  • Hold enheden ren og tør. Brug en blød, tør klud til at tørre overfladen af.
  • Undgå at udsætte enheden for ekstreme temperaturer, fugt eller direkte sollys.
  • Store the gauge in its protective leather case when not in use to prevent damage.
  • Replace batteries when the display becomes dim or the device fails to power on.

Fejlfinding

Hvis enheden ikke fungerer som forventet, skal du overveje følgende:

  • Intet display/dæmpet display: Check or replace the LR44 batteries. Ensure they are inserted with correct polarity.
  • Upræcise læsninger: Ensure the device is on a stable, level surface. Perform the zero-setting (Tare) function before each measurement. Re-calibrate the device using the 5g weight. Avoid placing items weighing more than 5g on the scale.
  • "ERR" during Calibration: Repeat the calibration process carefully. Ensure the 5g weight is placed correctly and the device is stable.

Specifikationer

Produktdimensioner6.4 x 4.1 x 0.9 tommer
Varens vægt3.42 ounces (97 gram)
Fabrikantneotech
ModelnummerNTK018-US
Batterier3 LR44 batterier påkrævet (medfølger)
MaterialeRustfrit stål
Særlige funktionerAuto Shut Off, Backlit Display, Large Display, Lightweight

Garanti

This Neoteck product comes with an 18-month warranty. Please retain your proof of purchase for warranty claims.

Støtte

For further assistance or inquiries, please visit the official Neoteck store on Amazon: Neoteck Store.

Relaterede dokumenter - NTK018-US

Preview Neoteck NTK007 Series-ES Stregkodescanner Konfiguration og Funktioner
Detaljeret guide til Neoteck NTK007 Series-ES stregkodescanneren, der dækker dens introduktion, multiscan-funktioner, buzzer-/LED-indikatorer og forskellige konfigurationsparametre til forskellige scanningstilstande, grænseflader og kommunikationsindstillinger.
Preview Brugermanual til ugentlig programmerbar timer
Brugermanual til Neotecks ​​ugentlige programmerbare timer, der beskriver dens funktioner, tekniske specifikationer og betjeningsvejledning til indstilling af tid og programmering af tænd/sluk-cyklusser.
Preview RLSOCO Czerwona Obudowa Ochronna do Multimetrów Fluke i Innych - Trwała i Stylowa
Elegancka, czerwona, półtwarda obudowa RLSOCO af zamkiem błyskawicznym, wykonana med ekologisk materiałów EVA i 1680D. Zapewnia bezpieczne przechowywanie og transport multimetrów cyfrowych Fluke (113-179, V88, 233) oraz marek Astroai, BEVA, Proster, Neoteck, HANMATEK, KAIWEETS, Tacklife. Posiada siatkową kieszeń na akcesoria. Dwóch lat gwarancji.