1. Introduktion
The Lightkiwi H5576 Digital Timer is designed to provide automated control for your low voltage landscape lighting system. This timer offers convenience and energy efficiency by allowing you to program specific on/off times for your lights. Its robust features and easy-to-read display make it an ideal solution for managing your outdoor illumination.
Nøglefunktioner:
- Automatically Turns Your Low Voltage Lighting System On/Off
- Easy Set Up Operation
- Large, Easy to Read Digital LCD Display
- Automatic or Manual Operation
- Program Up To 18 On/Off Settings Per Week

2. Sikkerhedsoplysninger
Please read all instructions carefully before using this product. Failure to follow these instructions may result in electric shock, fire, or serious injury. Keep this manual for future reference.
- Nedsænk ikke timeren i vand, og udsæt den ikke for overdreven fugtighed.
- Ensure the timer is properly plugged into a compatible outlet.
- Do not exceed the maximum electrical ratings: 15 Amps, 1875 Watts Resistive or General Purpose; 8 Amps, 1000 Watts Tungsten.
- This timer is designed for 125 Volts AC, 60 Hz applications.
- Opbevares utilgængeligt for børn.
- Afbryd strømmen før rengøring eller udførelse af vedligeholdelse.
3. Opsætningsvejledning
The Lightkiwi H5576 Digital Timer is designed for easy integration with your low voltage landscape lighting system. It is specifically compatible with the Lightkiwi 300 Watt Transformer (Model# W9715). Please note that this timer does not fit into 75 watt transformers due to their built-in mechanical timers.
Indledende opsætning:
- Pak timeren ud: Tag forsigtigt timeren ud af emballagen.
- Undersøg timeren: Tjek for synlige skader.
- Tilslut: Insert the timer directly into a standard 125V AC, 60Hz wall outlet or the designated timer receptacle on your compatible Lightkiwi transformer. The timer features a battery backup to retain settings during power outages.
- Tilslut enhed: Plug the device you wish to control (e.g., your landscape lighting transformer) into the outlet on the side of the digital timer.


Opsætningsvideo:
Watch this official Lightkiwi video for a visual guide on setting up your timer with a Lightkiwi transformer:
Video: Timers for Lightkiwi Transformer. This video demonstrates the compatibility and connection of Lightkiwi timers with Lightkiwi transformers.
4. Betjeningsvejledning
The H5576 Digital Timer allows for both automatic and manual operation, with the ability to program up to 18 on/off settings per week. The large LCD display ensures easy readability.
Indstilling af den aktuelle tid:
- Tryk på TID knappen. Timevisningen blinker.
- Brug UP og NED knapper for at justere timen.
- Trykke TID igen. Minuttangivelsen vil blinke.
- Brug UP og NED knapper for at justere minutterne.
- Trykke TID again. The day of the week will flash.
- Brug UP og NED knapper for at vælge den aktuelle dag.
- Trykke TID for at bekræfte og afslutte tidsindstillingstilstand.
Programming On/Off Cycles:
You can set up to 18 distinct ON/OFF programs. Each program consists of an ON time and an OFF time.
- Tryk på SÆT button. The display will show "1 ON" and the hour will flash.
- Bruge UP og NED to set the desired ON hour for program 1.
- Trykke SÆT. Set the ON minutes using UP og NED.
- Trykke SÆT. Set the day(s) of the week for this ON program using UP og NED. You can choose individual days, weekdays, weekends, or all days.
- Trykke SÆT. The display will show "1 OFF" and the hour will flash.
- Repeat steps 2-4 to set the desired OFF time and day(s) for program 1.
- Fortsæt med at trykke SÆT to cycle through programs 2-18 and set them as needed. If you do not need all 18 programs, simply press CTD for at forlade programmeringstilstand.
Manuel tilsidesættelse:
For manuelt at tænde eller slukke den tilsluttede enhed skal du trykke på MANUEL button. Each press will cycle through ON, OFF, and AUTO modes. In AUTO mode, the timer will follow your programmed settings.
Tilfældig funktion:
De RND (Random) button can be used to activate a random on/off pattern, which can be useful for security purposes when you are away. Consult the full user guide (link in product documents) for detailed instructions on using the random function.
5. Vedligeholdelse
The Lightkiwi H5576 Digital Timer requires minimal maintenance to ensure long-lasting performance.
- Rensning: Wipe the timer with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure the timer is unplugged before cleaning.
- Opbevaring: Hvis timeren opbevares i længere tid, skal den sørges for at være ren og tør. Opbevares køligt og tørt, beskyttet mod direkte sollys.
- Batteri-sikkerhedskopi: The internal battery maintains settings during power outages. If the display is blank or settings are lost frequently, the battery may need to be recharged by keeping the unit plugged in for several hours.
6. Fejlfinding
If you encounter issues with your Lightkiwi H5576 Digital Timer, please refer to the following common problems and solutions:
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Timerdisplayet er tomt. | No power; internal battery drained. | Ensure the timer is securely plugged into a live outlet. Leave it plugged in for several hours to recharge the internal battery. |
| Connected device does not turn on/off at programmed times. | Incorrect programming; timer in manual mode; power outage. | Verify your ON/OFF programs are set correctly. Press the MANUEL button until the timer is in AUTO mode. Check for power outages. |
| Vanskeligheder med at programmere timeren. | Unfamiliarity with button sequence. | Refer to the "Operating Instructions" section (Section 4) and follow the steps carefully. It may be helpful to unplug the timer and program it in a comfortable setting before re-installing. |
| Timer trips circuit breaker. | Overload; incompatible transformer. | Ensure the connected load does not exceed the timer's maximum wattage (1875W). Verify compatibility with your transformer (e.g., Lightkiwi 300W Transformer Model# W9715). Do not use with 75W transformers. |
7. Specifikationer
| Specifikation | Detalje |
|---|---|
| Modelnummer | H5576 |
| Mærke | Lightkiwi |
| Farve | Hvid |
| Materiale | Plast |
| Input bindtage | 125 Volt AC, 60 Hz |
| Max. Input Current/Watt | 15 Amps, 1875 Watts Resistive or General Purpose |
| Wolframvurdering | 8 Amps, 1000 Watt Tungsten |
| Antal indstillinger | Up to 18 On/Off settings per week |
| Produktdimensioner | 3.5 x 3 x 2.5 tommer |
| Varens vægt | 3.84 ounce |
| Certificeringer | ETL opført |
| UPC | 615953178111 |
8. Garanti og support
Lightkiwi is committed to providing high-quality products. For specific warranty information regarding your H5576 Digital Timer, please refer to the documentation included with your purchase or visit the official Lightkiwi webwebsted.
Kundesupport:
If you have any questions, require technical assistance, or need to report an issue, please contact Lightkiwi customer support. You can find contact information and additional resources by visiting the Lightkiwi Brand Store on Amazon eller deres embedsmand webwebsted.