1. Introduktion
This manual provides instructions for the installation, operation, and maintenance of the Shelti and Gold Standard Games Air Hockey and Dome Hockey Score Sensors (Part Number 210-0195-0). These sensors are designed as direct OEM replacements to ensure accurate scorekeeping on compatible game tables.
2. Kompatibilitet
These score sensors are specifically designed for use with the following Shelti and Gold Standard Games models:
- Shelti Dome Hockey: Breakout Slapshot
- Gold Standard Games Air Hockey: Home Pro, Elite Home Pro
Vigtig: These sensors are not compatible with air hockey tables from other manufacturers.
3. Pakkens indhold
- Score Sensor Assembly (Part Number 210-0195-0) x 1
4. Opsætning og installation
Before beginning installation, ensure the game table is powered off and unplugged from the electrical outlet to prevent injury or damage.

Figur 1: Shelti Gold Standard Games Air Hockey Dome Hockey Score Sensor assembly. This image displays the sensor unit, which consists of a black cable terminating in a modular connector (likely RJ11 or similar) on one end, and two sensor components connected by thin red, blue, yellow, and green wires on the other end. The main cable is coiled, and the sensor components are black plastic with small metal elements.
- Access the Goal Area: Depending on your specific table model, you may need to remove the goal assembly or access panel to reach the existing score sensors. Refer to your game table's primary instruction manual for specific disassembly procedures.
- Disconnect Old Sensors: Carefully disconnect the wiring from the old score sensors. Note the orientation and connection points of the wires before removal.
- Remove Old Sensors: Unmount the old sensor components from their positions within the goal.
- Install New Sensors: Mount the new Shelti/Gold Standard Games score sensor components into the designated slots or brackets within the goal area. Ensure they are securely fastened and properly aligned to detect pucks passing through the goal.
- Tilslut ledninger: Connect the wires from the new sensor assembly to the corresponding terminals or connectors on your game table's scoring system. The modular connector (RJ11 type) should plug into the appropriate port on the scoring board or wiring harness. Ensure all connections are firm.
- Saml igen: Replace any removed panels or goal assemblies.
- Test funktionalitet: Plug in and power on the game table. Test the sensors by passing a puck through each goal to verify that the score registers correctly on the scoreboard.
5. Betjening
Once installed, the score sensors operate automatically. When a puck passes through the goal and interrupts the sensor's beam, the scoring system registers a point for the corresponding player. The sensors are designed for quick and accurate detection.
6. Vedligeholdelse
- Rensning: Periodically inspect the sensor components for dust, debris, or obstructions. Gently clean the sensor lenses with a soft, dry cloth. Avoid using abrasive cleaners or solvents.
- Ledningsinspektion: Occasionally check the wiring for any signs of wear, fraying, or loose connections. Ensure all cables are securely routed and not pinched.
- Miljøforhold: Operate the game table in a clean, dry environment. Extreme temperatures or humidity can affect electronic components.
7. Fejlfinding
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Score not registering | Sensor obstructed or misaligned. Loose wiring connection. Faulty sensor. | Check for debris blocking the sensor path. Ensure sensors are securely mounted and aligned. Verify all wiring connections are firm. If issues persist, the sensor may need replacement. |
| Intermittent scoring | Loose connection. Minor obstruction. | Inspect wiring for intermittent contact. Clean sensor area thoroughly. |
| Sensor does not detect fast-moving pucks (Bubble Hockey specific) | (Note from product reviews) Sensor response time may not be suitable for very fast puck travel in certain non-compatible setups. | These sensors are designed for Shelti and Gold Standard Air Hockey tables. They may not be suitable for other game types, such as some bubble hockey games, where puck travel through the sensor area is extremely rapid. Ensure compatibility with your specific game model. |
8. Specifikationer
- Varenummer: 210-0195-0
- Mærke: Shelti / Gold Standard Games
- Materiale: Acrylonitril Butadien Styren (ABS)
- Farve: Sort
- Kompatibilitet: Shelti Dome Hockey (Breakout Slapshot), Gold Standard Games Air Hockey (Home Pro, Elite Home Pro)
- Dimensioner: Approximately 80 x 0.19 x 0.19 inches (overall cable length and sensor size)
- Vægt: Cirka 0.8 ounce
9. Garanti og support
Specific warranty information for this replacement part may vary. Please refer to your original game table's warranty documentation or contact Shelti customer support for details regarding replacement parts.
For technical assistance or further inquiries, please visit the official Shelti webwebsted eller kontakt deres kundeserviceafdeling.