1. Introduktion

This manual provides comprehensive instructions for the installation, operation, and maintenance of the ComMax DR-4UM 4-Button Audio Intercom Lobby Panel. The DR-4UM is designed for use in 4-apartment buildings, facilitating audio communication between visitors at the lobby panel and residents within their apartments.

The DR-4UM functions as a key component of a wired intercom system, requiring integration with compatible ComMax interphone series units, such as the DP-SS (sold separately), and a DC12V power supply (ComMax RF-1A, sold separately).

ComMax DR-4UM 4-Button Audio Intercom Lobby Panel

Figure 1: ComMax DR-4UM 4-Button Audio Intercom Lobby Panel (Front View)

2. Pakkens indhold

Please verify that all items listed below are present in your package. If any items are missing or damaged, contact your supplier immediately.

Note: Additional accessories such as wiring cables, indoor handsets (e.g., DP-SS), power supply (e.g., RF-1A), and electric door strikes are not included and must be purchased separately.

3. Sikkerhedsoplysninger

Læs alle instruktioner omhyggeligt før installation og betjening. Gem denne manual til senere brug.

4. Opsætning og installation

4.1. Kompatibilitet

The DR-4UM lobby panel is designed to be compatible with ComMax interphone series, such as the DP-SS indoor handsets. Ensure all components of your intercom system are compatible before installation.

4.2. Montering

The DR-4UM is a flush-mounted unit. Select a suitable location at the building entrance, ensuring it is protected from direct weather exposure if possible, and at an appropriate height for visitors.

ComMax DR-4UM Installation Dimensions Diagram

Figure 2: Installation Dimensions (Measurements in mm)

Refer to Figure 2 for precise dimensions and mounting hole locations. Prepare the wall opening according to these measurements for a flush fit.

4.3. Ledningsdiagram

The DR-4UM requires a DC12V, 500mA power source (e.g., ComMax RF-1A). The wiring involves a common 3-wire connection plus individual wires for each apartment.

ComMax DR-4UM Wiring Diagram with DP-SS and RF-1A

Figure 3: Wiring Diagram for DR-nUM (DR-4UM) with DP-SS and RF-1A

Follow the wiring diagram in Figure 3 carefully. Connect the lobby panel to the indoor handsets (DP-SS) and the power supply (RF-1A). Ensure all connections are secure and correctly polarized. Incorrect wiring can damage the unit or prevent proper operation.

5. Betjeningsvejledning

The ComMax DR-4UM lobby panel provides simple and direct audio communication.

5.1. Calling an Apartment

  1. A visitor approaches the lobby panel.
  2. The visitor identifies the desired apartment number.
  3. The visitor presses the corresponding call button on the DR-4UM panel.
  4. An audible signal will sound at the indoor handset (DP-SS) in the selected apartment.

5.2. Tovejskommunikation

  1. Once the resident answers the call from their indoor handset, two-way audio communication is established.
  2. The visitor can speak into the microphone on the lobby panel.
  3. The resident can speak into their indoor handset.
  4. Communication will cease when either party hangs up their handset or after a predetermined time-out period.

6. Vedligeholdelse

Regular maintenance ensures the longevity and optimal performance of your ComMax DR-4UM lobby panel.

7. Fejlfinding

If you encounter issues with your DR-4UM lobby panel, refer to the following common problems and solutions.

ProblemMulig årsagLøsning
No audio when calling an apartment.
  • Forkert ledningsføring.
  • Ingen strøm til enheden.
  • Faulty indoor handset.
  • Check all wiring connections against the diagram (Figure 3).
  • Verify the DC12V power supply is connected and functioning.
  • Test with a known working indoor handset if possible.
Call button does not respond.
  • Loose connection to the button.
  • Fejlfunktion på knap.
  • Inspect internal connections for the specific button.
  • If problem persists, contact technical support.
Poor audio quality (static, low volume).
  • Løse ledningsforbindelser.
  • Interferens fra andre elektriske apparater.
  • Cable length exceeding recommended distance.
  • Kontroller alle ledninger for sikre forbindelser.
  • Ensure proper cable shielding and routing away from power lines.
  • Refer to specifications for maximum communication distance and cable diameter.

If the problem persists after attempting these solutions, please contact ComMax technical support.

8. Specifikationer

Technical specifications for the ComMax DR-4UM 4-Button Audio Intercom Lobby Panel.

ComMax DR-4UM Technical Specifications Table

Figure 4: ComMax DR-4UM Technical Specifications

FeatureDetalje
ModelDR-4UM
StrømkildeDC12V, 1Amp (ComMax RF-1A recommended, sold separately)
LedningsføringCommon 3 wires + Individual 1 wire per apartment
Kommunikationstype2-vejs lyd
MonteringstypeIndbygget
Driftstemperatur-10 ° C ~ 50 ° C (14 ° F ~ 122 ° F)
Dimensioner (B x H x D)142 mm x 250 mm x 50 mm (5.59 x 9.84 x 1.97 tommer)
MaterialeAluminium
FarveSølv
Varens vægt907.18 gram (2 pund)
Kompatible enhederComMax interphone series (e.g., DP-SS)
ForbindelsesteknologiKablet
KontrolmetodeStemme
UPC730957987658

8.1. Communication Distance vs. Cable Diameter

Kabeldiameter (mm)Max. Distance (m)
Ø0.530 m
Ø0.6550 m
Ø0.870 m
Ø1100 m

9. Garanti og support

For warranty information, please refer to the warranty card included with your product or contact your local ComMax distributor.

For technical support, installation assistance, or troubleshooting beyond the scope of this manual, please contact ComMax customer service or visit the official ComMax webwebsted for supportressourcer.

Relaterede dokumenter - DR-4UM

Preview COMMAX DP-2K, DP-201R, DP-20H/20HR Intercom-system: Installations- og betjeningsmanual
Installations- og betjeningsmanual til COMMAX DP-2K, DP-201R, DP-20H og DP-20HR audio-intercomsystemer. Indeholder sikkerhedsadvarsler, komponentbeskrivelser, tilslutningsdiagrammer, tekniske specifikationer, kompatibilitetsoplysninger, retningslinjer for bortskaffelse af WEEE og EU-overensstemmelseserklæring.
Preview COMMAX DR-nUM / DR-nUS Dørstation Brugermanual
Brugermanual til COMMAX DR-nUM og DR-nUS dørstationer, der dækker introduktion, sikkerhedsforanstaltninger, overview, driftsmetoder, ledningsføring, styklister og specifikationer.
Preview COMMAX Dørtelefon DR-201D Brugermanual
Brugermanual til COMMAX dørtelefon DR-201D, med detaljerede specifikationer, ledningsføring, installation og betjening.
Preview COMMAX dørtelefon DP-4VHP brugermanual og sikkerhedsvejledning
Omfattende brugermanual til COMMAX DP-4VHP dørtelefonen, der dækker installation, betjening, sikkerhedsforanstaltninger, specifikationer og kontaktoplysninger. Indeholder tydelige instruktioner og advarsler.
Preview COMMAX DP-LA01M, LA01S Dørtelefon Brugermanual
Brugermanual til COMMAX DP-LA01M og DP-LA01S dørtelefoner, der dækker advarsler, overview, betjening, ledningsføring og specifikationer. Indeholder oplysninger om COMMAX DR-2K-panelet.
Preview Katalog Produktów COMMAX: Wideodomofony, Domofony, Interkomy og Akcesoria
Odkryj pełną gamę produktów COMMAX, w tym wideodomofony, domofony, interkomy og akcesoria. Poznaj innowacyjne rozwiązania SmartHome & Security.