SFA 0015UP

Sanibroy 0015up Løftepumpe Sanipro XR Up Brugermanual

Model: 0015UP | Brand: SFA

1. Introduktion

The Sanibroy 0015up Lift Pump Sanipro XR Up is a compact and efficient macerating pump designed for the addition of a complete bathroom where traditional gravity drainage is not feasible. This unit allows for the connection of a WC, washbasin, shower, and bidet, providing a versatile solution for wastewater disposal. Its advanced design ensures quiet operation and features an accessible panel for maintenance without requiring complete unit removal or tank emptying.

2. Sikkerhedsoplysninger

3. Produktet er slutview

The Sanipro XR Up is a compact macerating pump system designed for efficient wastewater management. It features multiple inlets for various sanitary fixtures and a powerful motor for vertical and horizontal discharge.

eksploderede view of Sanibroy Sanipro XR Up lift pump showing top cover, motor, and various inlets/outlets.

Figur 3.1: eksploderede view of the Sanibroy Sanipro XR Up lift pump, illustrating the removable top cover, internal motor assembly, and connection points for various sanitary fixtures. This design facilitates easier access for maintenance.

Front view of the Sanibroy Sanipro XR Up lift pump with 'SANIPRO XR UP' label.

Figur 3.2: Front view of the Sanibroy Sanipro XR Up lift pump, highlighting the 'SANIPRO XR UP' branding and the main discharge outlet. The compact white casing is designed for discreet integration.

Nøglefunktioner:

4. Opsætning og installation

The Sanipro XR Up is designed for installation in a bathroom setting, typically behind a toilet or within a vanity unit. Due to the nature of plumbing and electrical connections, professional installation is strongly recommended.

Installationstrin (Overview):

  1. Placering: Place the unit on a firm, level surface, ensuring adequate space for connections and future maintenance access.
  2. Toilettilslutning: Connect the toilet outlet to the main inlet of the Sanipro XR Up using the provided connector. Ensure a watertight seal.
  3. Yderligere armaturtilslutninger: Connect the washbasin, shower, and bidet waste pipes to the auxiliary inlets on the unit. Use appropriate adapters and ensure all connections are sealed.
  4. Tilslutning af udløbsrør: Connect the discharge pipe from the unit to the main drainage system. The unit can pump wastewater up to 5 meters vertically or 100 meters horizontally. Ensure the discharge pipe has a continuous fall towards the main drain after any vertical lift.
  5. Ventilation: Ensure the unit is properly vented according to local plumbing codes.
  6. Elektrisk tilslutning: Connect the unit to a dedicated, properly grounded electrical outlet (230 Volts, 400 Watts). This connection must be made by a qualified electrician.
  7. Test: After all connections are secure, turn on the water supply and electrical power. Flush the toilet and run water in the sink/shower to test for leaks and proper operation of the pump.
Sanibroy Sanipro XR Up lift pump installed behind a toilet in a modern bathroom setting, connected to a sink and shower.

Figur 4.1: En eksample installation of the Sanibroy Sanipro XR Up lift pump in a bathroom. The unit is discreetly placed behind a toilet, with connections visible for a washbasin and a shower, demonstrating its integration capabilities.

5. Betjeningsvejledning

The Sanipro XR Up operates automatically. When wastewater enters the unit from connected fixtures, a pressure switch activates the motor, which macerates the waste and pumps it through the discharge pipe to the main drainage system.

6. Vedligeholdelse

Regular maintenance ensures the longevity and efficient operation of your Sanipro XR Up unit. The accessible panel simplifies routine checks.

Rutinemæssig vedligeholdelse:

  1. Strømafbrydelse: Always turn off and disconnect the power supply to the unit before performing any maintenance.
  2. Adgangspanel: The Sanipro XR Up features an access panel that allows for inspection and clearing of minor blockages without needing to fully remove the unit or empty the tank. Carefully open this panel as per the detailed instructions in the full product manual (not provided here).
  3. Rensning: Rengør enhedens yderside regelmæssigt med enamp cloth. For internal cleaning, specialized macerator descalers can be used following the product's instructions. Avoid abrasive cleaners.
  4. Inspektion: Regularly inspect all connections for leaks and ensure the discharge pipe is free from obstructions.
Gennemsigtig view of the Sanibroy Sanipro XR Up lift pump showing internal components like the motor, macerator blades, and various pipe connections.

Figur 6.1: Gennemsigtig view of the Sanibroy Sanipro XR Up, revealing its internal components including the motor, macerator blades, and the intricate network of inlet and outlet pipe connections. This illustrates the complexity and precision of the unit's engineering.

7. Fejlfinding

If you encounter issues with your Sanipro XR Up, consult the following troubleshooting guide. For complex problems, contact a qualified technician.

ProblemMulig årsagLøsning
Pumpen starter ikkeNo power supply; Clogged pressure switch; Motor fault.Check power connection and circuit breaker; Disconnect power and inspect for blockages around the pressure switch; Contact service technician.
Pumpen kører kontinuerligtPressure switch fault; Leak in connected fixtures; Blockage preventing proper discharge.Check for leaks in toilet or other fixtures; Disconnect power and inspect for blockages in the unit or discharge pipe; Contact service technician.
Overdreven støj/vibrationForeign object in macerator; Loose mounting; Worn motor bearings.Disconnect power and carefully inspect macerator for foreign objects (refer to maintenance section); Ensure unit is securely mounted; Contact service technician.
Water not dischargingDischarge pipe blockage; Pump impeller jammed; Airlock in system.Check discharge pipe for obstructions; Disconnect power and inspect impeller for foreign objects; Ensure proper venting.

8. Specifikationer

Detailed technical specifications for the Sanibroy 0015up Lift Pump Sanipro XR Up.

9. Garanti og support

For warranty information, technical support, or service inquiries, please contact your authorized SFA dealer or the retailer from whom the product was purchased. It is recommended to retain your proof of purchase for warranty claims.

Always ensure that any service or repair work is carried out by qualified personnel to maintain product integrity and warranty validity.

Relaterede dokumenter - 0015UP

Preview SFA SANIPRO XR Maceratorpumpe: Installations-, drifts- og fejlfindingsvejledning
Omfattende vejledning til SFA SANIPRO XR maceratorpumpen, der dækker installation, anvendelser, elektriske tilslutninger, idriftsættelse, vedligeholdelse, fejlfinding og garanti. Indeholder tekniske specifikationer og flersprogede instruktioner.
Preview SFA Special Sanibroyeur Afkalkningsmiddel - Sikkerhedsdatablad
Sikkerhedsdatablad for SFA Special Sanibroyeur afkalkningsmiddel, der indeholder oplysninger om identifikation, farer, sammensætning, førstehjælp, håndtering, opbevaring og lovgivningsmæssige oplysninger.
Preview SFA Sanidouche/Sanishower/Sanipump Installations- og brugermanual
Omfattende vejledning til installation og brug af SFA Sanidouche, Sanishower og Sanipump spildevandsløfteanlæg. Indeholder sikkerhed, anvendelser, vedligeholdelse, fejlfinding og tekniske specifikationer.
Preview SFA Sanidouche, Sanishower, Sanipump Installations- og brugermanual
Omfattende vejledning til installation, drift, vedligeholdelse og fejlfinding af SFA Sanidouche, Sanishower og Sanipump spildevandsløfteanlæg. Dækker produktfunktioner, sikkerhedsinstruktioner og tekniske specifikationer.
Preview SFA SANICUBIC 1 VX: Installationsmanual og tekniske data
Detaljeret installationsvejledning, tekniske specifikationer og fejlfindingsoplysninger til SFA SANICUBIC 1 VX spildevandsløftestationen. Indeholder diagrammer, stykliste og kontaktoplysninger.
Preview SFA SANIVITE / SANIPUMP 2 spildevandspumpe installations- og brugermanual
Comprehensive installation, operation, maintenance, and troubleshooting guide for the SFA SANIVITE / SANIPUMP 2 wastewater pump, covering safety, applications, electrical connections, and warranty information. Includes detailed textual descriptions of diagrams and multilingual instructions.