This manual provides essential information for the safe and efficient installation, operation, and maintenance of your AERMEC OMNIA UL Series Fan Coil Unit, model UL16C+ZU. This fan convector is designed for both heating and cooling applications, featuring an electronic thermostat for precise temperature and speed control. Please read this manual thoroughly before using the product and retain it for future reference.
The AERMEC OMNIA UL16C+ZU is a versatile unit suitable for floor installation, capable of operating at low temperatures for heating (e.g., 50°C instead of 70°C) and providing effective air conditioning. It comes with a roof cabinet (sheath) in white RAL 9002 and clogs in RAL 7044.
2. Sikkerhedsoplysninger
- Always disconnect the unit from the power supply before performing any maintenance or cleaning.
- Installation and repairs must be carried out by qualified personnel only, in accordance with local regulations and standards.
- Sørg for, at strømforsyningen voltage matches the specifications indicated on the unit's rating label.
- Do not block the air intake or outlet grilles.
- Hold børn og kæledyr væk fra enheden under drift.
- Indsæt ikke genstande i enheden.
- Hvis netledningen er beskadiget, skal den udskiftes af producenten, dennes serviceagent eller lignende kvalificerede personer for at undgå en fare.
3. Produktet er slutview
The AERMEC OMNIA UL16C+ZU fan coil unit is designed for efficient climate control. Key features include:
- UL-srx140m: Suitable for both horizontal and vertical construction.
- C: Version with Thermostat: Equipped with an electronic thermostat for precise control.
- Rengøring af ventilator: Designed for easy fan cleaning access.
- Condensation Tub: Features a tub for condensation collection that requires periodic cleaning.
- Alsidig installation: Hydraulic taps can be installed on either the left or right side.

Figure 1: AERMEC OMNIA UL Series Fan Coil Unit (Model UL16C+ZU)
Dette billede viser forsiden view of the AERMEC OMNIA UL Series Fan Coil Unit, showcasing its compact design and white finish, suitable for floor installation.
4. Opsætning og installation
The AERMEC OMNIA UL16C+ZU is designed for floor-mounted installation. Ensure the installation location provides adequate space for air circulation and maintenance access.
- Udpakning: Carefully remove the unit from its packaging. Inspect for any damage incurred during transit.
- Placering: Place the unit on a stable, level surface. The unit is supplied with a roof cabinet (sheath) and clogs for complete floor installation.
- Hydrauliske forbindelser: The hydraulic taps can be installed on either the left or right side of the unit. Consult a qualified plumber for proper connection to your heating/cooling system. Ensure all connections are secure and leak-free.
- Elektriske forbindelser: Connect the unit to a suitable electrical supply. This unit operates on electric current. All electrical work must be performed by a qualified electrician in accordance with local electrical codes.
- Termostatforbindelse: The unit includes an electronic thermostat. Ensure it is correctly wired and configured according to the specific wiring diagram provided with the unit (not detailed in this general manual).

Figure 2: Installation Diagram for AERMEC OMNIA UL Series
This diagram illustrates typical installation configurations for the AERMEC OMNIA UL Series, showing options for wall and floor mounting, and the general layout of connections.

Figure 3: Dimensions of AERMEC OMNIA UL Series
This image provides detailed dimensional drawings for various OMNIA UL models, including length, height, depth, and weight, crucial for planning installation space.
5. Betjeningsvejledning
Your AERMEC OMNIA UL16C+ZU fan coil unit is equipped with an electronic thermostat for user-friendly control.
- Tænd/sluk: Use the main power switch (if present) or the thermostat control to turn the unit on or off.
- Temperaturjustering: Use the controls on the electronic thermostat to set your desired room temperature. The unit will automatically adjust its operation to maintain this setting.
- Operating Modes (Heating/Cooling): The unit can function in both heating and cooling modes. Select the appropriate mode via the thermostat interface. The unit is efficient for heating at lower water temperatures (e.g., 50°C).
- Blæserhastighedskontrol: The electronic thermostat also allows you to adjust the fan speed. Choose a lower speed for quieter operation or a higher speed for faster temperature changes.
Refer to the specific instructions provided with your electronic thermostat for detailed operation of its features and settings.
6. Vedligeholdelse
Regular maintenance ensures optimal performance and longevity of your fan coil unit. Always disconnect power before maintenance.
- Rengøring af ventilator: Periodically clean the fan blades to prevent dust accumulation, which can reduce efficiency and airflow. Access the fan compartment as per the unit's design (refer to specific diagrams if available).
- Condensation Tub Cleaning: The tub for condensation should be cleaned regularly to prevent blockages and the growth of mold or bacteria. Ensure the drain is clear.
- Rengøring/udskiftning af filter: While not explicitly listed, most fan coil units have air filters. Check your unit for filters and clean or replace them as recommended by AERMEC to maintain air quality and unit efficiency.
- Udvendig rengøring: Tør de udvendige overflader af med en blød, damp klæde. Brug ikke slibende rengøringsmidler eller opløsningsmidler.
7. Fejlfinding
If you encounter issues with your AERMEC OMNIA UL16C+ZU, consider the following basic troubleshooting steps:
- Enheden tænder ikke:
- Check if the unit is properly plugged into a power outlet.
- Kontroller, at afbryderen ikke er udløst.
- Ensure the thermostat is set to an active mode and desired temperature.
- Utilstrækkelig opvarmning/køling:
- Check if the air filters are clean and not obstructed.
- Ensure the air intake and outlet grilles are not blocked.
- Verify the thermostat settings are appropriate for the desired temperature.
- Confirm that the hydraulic system is functioning correctly and water is circulating.
- Usædvanlig støj:
- Check for loose components or debris inside the unit.
- Sørg for, at enheden er vandret og stabil.
If problems persist after performing these checks, contact a qualified service technician for assistance.
8. Specifikationer
| Feature | Detalje |
|---|---|
| Mærke | AERMEC |
| Modelnummer | UL16C+ZU |
| Farve | White Ral9002 Feet Ral7044 |
| Produktdimensioner | 75 x 51.3 x 17.3 cm |
| Varens vægt | 28 kg |
| Materiale | Plast |
| Særlige funktioner | Electronic thermostat for regulating speed and room temperature |
| Elektrisk ventilator design | Gulv Fan |
| Strømkilde | Elektrisk strøm |
| Stil | Moderne |
| Værelsestype | Bathroom (also suitable for other rooms) |
| Anbefalede anvendelser | Cooling, Ventilating, Heating |
| Monteringstype | Gulvmonteret |
| ASIN | B01MTW5F82 |
| Dato først tilgængelig | 16. maj 2017 |
9. Garanti og support
For warranty information and technical support, please refer to the documentation provided with your purchase or contact AERMEC customer service directly. Keep your proof of purchase for warranty claims.
Manufacturer: aermec