1. Introduktion
The Calix P-Series 716GE-I is an Indoor Optical Network Terminal (ONT) designed to provide high-speed fiber optic connectivity for residential and business environments. This device acts as the demarcation point between the fiber optic network and your internal network, offering multiple Ethernet ports for data services and phone ports for voice services.
This manual provides detailed instructions for the setup, operation, maintenance, and troubleshooting of your 716GE-I ONT.
2. Produktet er slutview
2.1 Nøglefunktioner
- Four (4) Gigabit Ethernet (LAN) ports for high-speed data connectivity.
- Two (2) Voice (Phone) ports for traditional telephone services.
- Optical Fiber Port for connection to the fiber optic network.
- Compact indoor design.
- WPS (Wi-Fi Protected Setup) feature (Note: This device is an ONT, not a Wi-Fi router. WPS functionality may refer to a related feature or be a general specification for Calix devices).
- Managed via Calix OS and App control.
2.2 Physical Description: Ports and Indicators

Figur 1: Forside og side view of the Calix 716GE-I ONT, highlighting the indicator lights for Power, CPU, WAN, Phone, and LAN ports.

Figur 2: Top view of the Calix 716GE-I ONT, showing the indicator lights and a caution label for Class 1 Laser Product near the fiber input.

Figur 3: Bag view of the Calix 716GE-I ONT, displaying the four LAN ports, two Phone ports, Reset button, and Power input.

Figur 4: Bagside view of the Calix 716GE-I ONT, providing a clearer look at the port layout and the fiber optic connection area, which is typically covered or managed by a service technician.

Figur 5: Bund view of the Calix 716GE-I ONT, showing the product label with model number, serial number, MAC address, and regulatory compliance information. This information is crucial for support and device registration. For more product details, visit: Calix Produktinformation.
LED-indikatorer:
- MAGT: Indicates the power status of the ONT.
- CPU: Indicates the operational status of the ONT's central processing unit.
- WAN: Indicates the status of the fiber optic connection to the Wide Area Network.
- PHONE (1, 2): Indicates the status of the voice service lines.
- LAN (1, 2, 3, 4): Indicates the status of the Ethernet connections to local devices.
3. Opsætning
3.1 Sikkerhedsforanstaltninger
WARNING: This product contains a Class 1 Laser. Do not look directly into the optical port or fiber optic cable ends when the device is powered on, as this can cause eye damage. Fiber optic connections should only be handled by qualified service technicians.
3.2 Placering
Place the ONT in a central location within your premises, away from direct sunlight, heat sources, and moisture. Ensure adequate ventilation around the device. Avoid placing it near large metal objects or appliances that may cause interference.
3.3 Connecting the ONT
- Fiberoptisk forbindelse: The fiber optic cable (typically a thin, yellow or blue cable) should already be connected to the ONT by your service provider. Do not attempt to connect or disconnect the fiber optic cable yourself unless instructed by a qualified technician.
- Strømtilslutning: Connect the provided power adapter to the "POWER" port on the rear of the ONT and then plug the adapter into a standard electrical outlet. The POWER LED on the front of the ONT should illuminate.
- Ethernet-enheder: Connect your computers, routers, or other network devices to the "LAN 1-4" ports using standard Ethernet cables. The corresponding LAN LED will illuminate when a connection is established.
- Telephone Devices: If you have voice services, connect your analog telephones or fax machines to the "PHONE 1" or "PHONE 2" ports using standard RJ-11 telephone cables. The PHONE LED will illuminate when the service is active.
Allow a few minutes for the ONT to power on and establish a connection with the network. The WAN and CPU LEDs should eventually turn solid, indicating a successful connection.
4. Betjening
4.1 Forståelse af LED-indikatorer
| LED navn | Status | Beskrivelse |
|---|---|---|
| MAGT | Solid grøn | The ONT is powered on and operating normally. |
| Slukket | The ONT is not receiving power. | |
| CPU | Solid grøn | The ONT's CPU is functioning correctly. |
| Blinkende grønt | The ONT is booting up or processing. | |
| Slukket | CPU error or device not powered. | |
| WAN | Solid grøn | The ONT has successfully established a connection to the fiber optic network. |
| Blinkende grønt | The ONT is attempting to establish a connection to the network. | |
| Slukket | No fiber signal detected or connection issue. | |
| PHONE (1, 2) | Solid grøn | Voice service is active and available. |
| Blinkende grønt | Phone line is in use (off-hook). | |
| Slukket | Voice service is not active or phone is on-hook. | |
| LAN (1-4) | Solid grøn | A device is connected to the corresponding LAN port and is active. |
| Blinkende grønt | Data activity is occurring on the corresponding LAN port. | |
| Slukket | No device is connected or the connected device is inactive. |
5. Vedligeholdelse
5.1 Generel pleje
- Keep the ONT in a clean, dust-free environment.
- Do not block the ventilation openings on the device.
- Avoid exposing the ONT to extreme temperatures, humidity, or direct sunlight.
- Do not drop or subject the ONT to strong impacts.
5.2 Rengøring
To clean the exterior of the ONT, use a soft, dry cloth. Do not use liquid cleaners, aerosol cleaners, or solvents, as these may damage the device. Ensure the device is unplugged from the power source before cleaning.
6. Fejlfinding
If you experience issues with your Calix 716GE-I ONT, refer to the following common troubleshooting steps. If the problem persists, contact your internet service provider for assistance.
6.1 No Power (POWER LED Off)
- Ensure the power adapter is securely connected to the ONT's POWER port and the electrical outlet.
- Kontroller, at stikkontakten fungerer ved at tilslutte en anden enhed.
- Prøv en anden stikkontakt.
6.2 No Internet Connection (WAN LED Off or Flashing)
- Check if the fiber optic cable is securely connected to the ONT. Do not attempt to re-seat the fiber cable yourself. Contact your service provider.
- Restart the ONT by unplugging the power adapter, waiting 30 seconds, and then plugging it back in.
- If the WAN LED remains off or continues to flash after restarting, there may be an issue with the fiber signal from your service provider. Contact them for support.
6.3 No LAN Connectivity (LAN LED Off)
- Ensure the Ethernet cable is securely connected between the ONT's LAN port and your device (e.g., computer, router).
- Prøv et andet Ethernet-kabel.
- Connect your device to a different LAN port on the ONT.
- Restart both the ONT and the connected device.
6.4 No Phone Service (PHONE LED Off)
- Ensure your telephone is properly connected to the PHONE 1 or PHONE 2 port.
- Check if the phone line is working by testing with another phone or by calling your number from a mobile phone.
- Restart the ONT.
- Hvis problemet fortsætter, skal du kontakte din tjenesteudbyder.
6.5 Nulstil knap
The ONT features a recessed "RESET" button on the rear panel. Pressing this button with a paperclip or similar pointed object for a short duration (less than 5 seconds) will typically restart the device. Holding it for a longer duration (e.g., 10-15 seconds) may restore factory default settings. Use the factory reset function only if instructed by your service provider, as it will erase all custom configurations.
7. Specifikationer
| Feature | Detalje |
|---|---|
| Modelnavn | Calix 716GE-I |
| Fabrikant | Calix |
| Forbindelsesteknologi | Optisk fiberport |
| Antal havne | 4 (LAN) + 2 (Phone) |
| Frekvensbåndsklasse | Single-Band (refers to optical signal, not Wi-Fi) |
| Speciel funktion | WPS (Wi-Fi Protected Setup) - Note: This feature may be for compatibility with other Calix devices or a general specification. The 716GE-I is an ONT, not a Wi-Fi router. |
| Kompatible enheder | Laptop, Personal Computer, Smartphone, Tablet (via connected router/switch) |
| Operativsystem | Calix OS |
| Kontrolmetode | App (likely referring to service provider management apps) |
| Farve | Sort |
| Varens vægt | 2 pund |
| Pakkedimensioner | 10 x 6 x 3 tommer |
| Dato først tilgængelig | 22. februar 2017 |
8. Garanti og support
8.1 Garantioplysninger
The Calix 716GE-I ONT is typically provided by your internet service provider (ISP) as part of their service. Warranty coverage for this device is generally handled directly by your ISP. Please refer to your service agreement or contact your ISP for specific warranty terms and conditions.
Note: The product label may indicate "LIFETIME [LOGIC]" which refers to the expected operational lifespan of the internal components under normal conditions, not necessarily a consumer warranty.
8.2 Teknisk support
For technical assistance, troubleshooting, or service-related inquiries regarding your Calix 716GE-I ONT, please contact your internet service provider (ISP). Your ISP is responsible for the installation, configuration, and ongoing support of the ONT as it is an integral part of their network infrastructure.
You may also find general product information and resources on the official Calix webwebsted: www.calix.com.