APC SRT5KRMXLT-5KTF

APC Smart-UPS SRT 5000VA Step-Down Transformer User Manual

Model: SRT5KRMXLT-5KTF

1. Introduktion

This manual provides essential information for the safe and efficient operation of your APC Smart-UPS SRT 5000VA RM 208V to 120V 2U Stepdown Transformer. This Uninterruptible Power Supply (UPS) is designed to provide reliable power protection and extended runtime for critical electronic equipment, ensuring business uptime and continuity during power disruptions.

The APC Smart-UPS SRT 5kVA is a double-conversion on-line pure sine wave UPS, suitable for IT professionals and network administrators. It features an embedded Network Management Card for remote monitoring and management, and supports graceful shutdown of physical servers, virtual machines, and HCI clusters via PowerChute Network Shutdown.

2. Sikkerhedsoplysninger

Read and understand all instructions before installing, operating, servicing, or maintaining this equipment. Adhere to all local and national electrical codes.

  • Fare for elektrisk stød: Denne enhed indeholder farlige voltages. Do not open the UPS enclosure. Servicing should only be performed by qualified personnel.
  • Batterisikkerhed: Batteries can present a risk of electrical shock and high short-circuit current. Observe proper precautions when working with batteries.
  • Vægtfare: The UPS is heavy. Use proper lifting techniques and sufficient personnel when moving or installing the unit. Refer to specifications for weight.
  • Ventilation: Sørg for tilstrækkelig luftgennemstrømning omkring UPS'en. Ventilationsåbningerne må ikke blokeres.
  • Miljø: Install the UPS in a controlled environment, free from excessive dust, moisture, and extreme temperatures.

3. Opsætning og installation

The APC Smart-UPS SRT 5000VA is a 5U rackmount unit. Proper installation is crucial for optimal performance and safety.

3.1 Udpakning og inspektion

Carefully unpack the UPS and inspect it for any shipping damage. Report any damage to the carrier and your dealer immediately.

3.2 Fysisk installation

Install the UPS in a standard 19-inch equipment rack. Due to its weight, it is recommended to use a lift or multiple personnel for safe installation.

Front view of the APC Smart-UPS SRT 5000VA rackmount unit

Figur 3.1: Forside view of the APC Smart-UPS SRT 5000VA rackmount unit, showing the front panel and rack ears.

3.3 Elektriske forbindelser

Ensure all connections are secure and comply with local electrical codes. The UPS requires a NEMA L6-30P input connection.

  • Hovedindgang: 208V-240V, 30A via NEMA L6-30P.
  • Udgangsbeholdere:
    • 12x NEMA 5-20R (120V)
    • 2x NEMA L6-20R (208V)
    • 2x NEMA L6-30R (208V)
Bag view of the APC Smart-UPS SRT 5000VA showing input and output receptacles

Figur 3.2: Bagside view of the APC Smart-UPS SRT 5000VA, illustrating the various input and output receptacles for power distribution.

The power cable length is 10 feet.

3.4 Network Management Card Setup

The UPS includes an embedded Network Management Card for network-based monitoring and management. Connect an Ethernet cable to the network port on the rear of the UPS. Refer to the Network Management Card documentation for detailed configuration instructions, including IP address assignment and network settings.

3.5 PowerChute Network Shutdown

Install PowerChute Network Shutdown software on your servers and virtual machines to enable graceful shutdown during extended power outages. This software communicates with the UPS via the Network Management Card.

4. Betjening af UPS'en

Once installed and connected, the UPS operates automatically to provide continuous power protection. The front panel display provides real-time status and configuration options.

4.1 Display på frontpanelet

The LCD display on the front panel provides critical information about the UPS status, input/output voltage, load, battery charge, and runtime. Use the navigation buttons to access different menus and settings.

Close-up of the APC Smart-UPS SRT 5000VA front panel display

Figur 4.1: Nærbillede view of the APC Smart-UPS SRT 5000VA front panel display, showing operational status and runtime information.

4.2 strømtilstande

The Smart-UPS SRT operates in various modes, including Online (double-conversion), Battery, and Bypass. The UPS automatically switches between modes as power conditions change.

4.3 Fjernovervågning og -styring

Utilize the embedded Network Management Card to monitor the UPS remotely via a web browser, SNMP, or network management software. The UPS can also connect to EcoStruxure IT or other third-party centralized management platforms for comprehensive infrastructure monitoring.

5. Vedligeholdelse

Regular maintenance ensures the longevity and reliability of your UPS system.

  • Udskiftning af batteri: The UPS batteries have a finite lifespan. Monitor the battery status via the front panel or network management interface. Replace batteries as recommended by APC.
  • Miljøtjek: Periodically check the installation environment to ensure it remains within recommended temperature and humidity ranges. Keep ventilation openings clear.
  • Firmwareopdateringer: Check the APC website for firmware updates for the UPS and Network Management Card to ensure optimal performance and security.

6. Fejlfinding

This section provides basic troubleshooting steps for common issues. For more complex problems, contact APC technical support.

ProblemMulig årsagLøsning
UPS not turning onNo input power; UPS switch off; discharged batteries.Check input power connection; ensure UPS is switched on; allow batteries to charge.
UPS beeping continuouslyPå batteristrøm; overbelastningstilstand; batterifejl.Check utility power; reduce load; check battery status.
"Overload" alarmConnected equipment exceeds UPS capacity.Disconnect non-essential equipment until load is within limits.

7. Specifikationer

FeatureDetalje
ModelnummerSRT5KRMXLT-5KTF
MærkeAPC
Kapacitet (VA/Watt)5000VA / 4800W
Input bindtage208V-240V
IndgangsforbindelseNEMA L6-30P
Udgang Voltage120V (NEMA 5-20R), 208V (NEMA L6-20R, NEMA L6-30R)
Outputbeholdere12x NEMA 5-20R, 2x NEMA L6-20R, 2x NEMA L6-30R
Formfaktor5U Rackmount
Dimensioner (H x B x D)8.58 tommer x 17.01 tommer x 28.31 tommer (21.79 cm x 43.21 cm x 71.91 cm)
Vægt218 lb (98.9 kg)
FarveSort
MaterialeMetal

8. Garanti og support

For warranty information, please refer to the warranty card included with your product or visit the official APC website. APC offers technical support and resources to assist with product installation, operation, and troubleshooting.

Du kan finde yderligere support og produktoplysninger ved at besøge APC-butik på Amazon eller den officielle APC webwebsted.

Relaterede dokumenter - SRT5KRMXLT-5KTF

Preview Tildeling af IP-adresse til APC-netværksstyringskort uden software
A technical guide detailing how to assign an IP address to an APC Network Management Card (NMC) using command-line tools like ARP and Ping, bypassing the need for proprietary APC software. This guide covers APC SmartUPS models and provides step-by-step instructions for network configuration.
Preview APC Smart-UPS SRT 10000VA 208V Tekniske specifikationer
Detaljerede tekniske specifikationer for APC Smart-UPS SRT 10000VA 208V, inklusive detaljer om output, input, batteri, kommunikation, fysiske, miljømæssige og overholdelsesstandarder. Model SRT10KXLT.
Preview APC Smart-UPS SRT 3000VA 208V Datablad og tekniske specifikationer
Omfattende teknisk datablad for APC Smart-UPS SRT 3000VA 208V, med detaljerede oplysninger om elektriske specifikationer, fysiske egenskaber, driftstid, miljømæssige driftsforhold og produktcertificeringer.
Preview Smart-UPS Firmware Opgraderingsguide v4.3.1 Brugervejledning
Brugervejledning til Schneider Electrics Smart-UPS Firmware Upgrade Wizard v4.3.1, der beskriver systemkrav, understøttede enheder, brugsnoter, fejlfinding og en trinvis gennemgang af opdatering af UPS-firmware.
Preview APC Easy-UPS Online Step-Down/Isolationstransformer SRV6-10KTF & SRV6-10KRTF Brugermanual
Denne manual indeholder vigtige sikkerhedsinstruktioner, udpakningsvejledning, specifikationer, installationsprocedurer, fejlfindingstips og serviceoplysninger for APC Easy-UPS On-Line Step Down/Isolation Transformer-modellerne SRV6-10KTF og SRV6-10KRTF.
Preview APC Smart-UPS Firmware Upgrade Wizard v4.2.0 Teknisk vejledning
En teknisk vejledning, der beskriver processen med at opgradere firmwaren til APC Smart-UPS-enheder ved hjælp af Firmware Upgrade Wizard v4.2.0. Den dækker systemkrav, understøttede enheder, brugsnoter og fejlfinding.