Salus Controls KL08RF (132801)

Salus Controls iT600 KL08RF Wireless Wiring Centre

Model: KL08RF (132801)

Brugermanual

1. Introduktion

The Salus Controls iT600 KL08RF is an 8-zone wireless wiring centre designed to simplify the installation and control of underfloor heating systems. It provides a central point for connecting thermostats, actuators, pumps, and boilers, facilitating efficient and organized heating management. This manual provides essential information for the safe and effective installation, operation, and maintenance of your KL08RF wiring centre.

2. Sikkerhedsoplysninger

ADVARSEL: Fare for elektrisk stød

  • Installation must be carried out by a qualified electrician in accordance with national and local wiring regulations.
  • Always disconnect the main power supply before performing any installation, maintenance, or wiring work.
  • Sørg for, at alle forbindelser er sikre og korrekt isolerede.
  • Udsæt ikke enheden for fugt eller ekstreme temperaturer.
  • Dette produkt er kun designet til indendørs brug.

3. Pakkens indhold

  • Salus Controls KL08RF Wireless Wiring Centre
  • Salus CO10RF USB Coordinator (Wireless Communication Dongle)
  • Monteringsskruer og vægdyvler
  • Brugervejledning (dette dokument)
Salus Controls KL08RF Wiring Centre and USB Coordinator in Retail Packaging

Figur 3.1: Salus Controls KL08RF Wiring Centre and USB Coordinator in Retail Packaging. This image shows the product as it appears when unboxed, including the main wiring centre unit, the separate USB coordinator, and the product's retail packaging.

4. Opsætning og installation

4.1 Mounting the Wiring Centre

Choose a suitable location for mounting the KL08RF wiring centre, preferably near the underfloor heating manifold and away from direct heat sources or moisture. Ensure adequate space for wiring connections.

  1. Mark the drilling points on the wall using the wiring centre as a template.
  2. Bor huller og indsæt vægpropper.
  3. Secure the wiring centre to the wall using the provided screws.
Salus Controls KL08RF Wireless Wiring Centre with Cover Closed

Figur 4.1: Salus Controls KL08RF Wireless Wiring Centre with Cover Closed. This image displays the wiring centre with its translucent cover securely in place, showing its compact and enclosed form factor once installed.

Dimensional Drawing of Salus Controls KL08RF Wiring Centre

Figur 4.2: Dimensional Drawing of Salus Controls KL08RF Wiring Centre. A technical drawing illustrating the precise measurements (length: 362.0 mm, width: 85.0-93.0 mm, height: 69.3 mm) of the KL08RF unit, crucial for planning installation space.

4.2 Ledningsforbindelser

The KL08RF wiring centre provides connections for up to 8 heating zones, a pump, a boiler, and a dew point sensor. Refer to the detailed wiring diagram below for proper connections.

Salus Controls KL08RF Wireless Wiring Centre with USB Dongle

Figur 4.3: Salus Controls KL08RF Wireless Wiring Centre with USB Dongle. This image shows the main unit with its cover open, revealing the internal terminals for power, zones 1-8, pump, boiler, and dew point sensor connections, along with the inserted CO10RF USB coordinator.

Close-up of KL08RF Connections and CO10RF USB Dongle

Figur 4.4: Close-up of KL08RF Connections and CO10RF USB Dongle. A detailed view of the wiring terminals, including the power input (L, N), G1/G2 terminals, zone outputs (1-8), pump, boiler, and dew point sensor connections. The CO10RF USB dongle (Device ID: 001E5E09090A17E9) is clearly visible in its dedicated port.

Typical Wiring Diagram for Salus Controls KL08RF

Figur 4.5: Typical Wiring Diagram for Salus Controls KL08RF. An illustrative diagram showing how to connect main power (L, N), underfloor heating manifold (230V to pump, 1.5mm² cable), optional boiler connection, and a dew point sensor to the KL08RF wiring centre. It also indicates connections for various thermostat types (G1/G2) and zone actuators.

Ledningstrin:

  1. Strømforsyning: Connect the main 230V AC power supply to the L and N terminals marked 'Power'.
  2. Zone Actuators: Connect the thermal actuators for each heating zone to the corresponding numbered terminals (1-8). Each zone typically requires two wires.
  3. Pumpe: Connect the underfloor heating pump to the terminals marked 'Pump'.
  4. Kedel: Connect the boiler control wires to the terminals marked 'Boiler'. This connection typically signals the boiler to fire when heat is required.
  5. Dew Point Sensor (Optional): If using, connect the dew point sensor to the designated terminals. This sensor helps prevent condensation in cooling applications.
  6. Termostatforbindelser: Connect your iT600 series wireless thermostats to the system. The KL08RF communicates wirelessly with these thermostats via the CO10RF USB coordinator.

4.3 Wireless Pairing (iT600 System)

The KL08RF acts as a receiver for wireless signals from iT600 series thermostats. The CO10RF USB coordinator facilitates this communication.

  1. Ensure the CO10RF USB coordinator is securely inserted into the USB port on the KL08RF.
  2. Follow the pairing instructions provided with your specific iT600 thermostats to link them to the KL08RF wiring centre. This typically involves putting both devices into a pairing mode.
  3. Once paired, the thermostats will wirelessly send heating demands to the KL08RF, which will then activate the corresponding zone actuators, pump, and boiler.

5. Operating the KL08RF

5.1 Indikatorlys

The KL08RF features several LED indicators to provide status information:

  • Power LED: Lyser, når enheden modtager strøm.
  • Netværksstatus LED: Indicates the status of the wireless network (e.g., solid for connected, flashing for searching).
  • Pair LED: Used during the pairing process with thermostats.
  • Zone-LED'er (1-8): Each LED illuminates when its corresponding zone is active and calling for heat.
  • Pump LED: Illuminates when the pump output is active.
  • Boiler LED: Illuminates when the boiler output is active.

5.2 Grundlæggende betjening

Once installed and paired, the KL08RF operates automatically based on the demands from the connected iT600 thermostats. When a thermostat calls for heat in a specific zone, the KL08RF will:

  • Activate the actuator for that zone.
  • Activate the heating pump.
  • Signal the boiler to fire (if connected).

The system will continue to operate until the thermostat's setpoint is reached or the heating demand is cancelled.

6. Vedligeholdelse

The Salus Controls KL08RF wiring centre requires minimal maintenance. Follow these guidelines:

  • Kontrollér ledningsforbindelserne med jævne mellemrum for at sikre, at de forbliver fastgjorte.
  • Hold enheden ren og fri for støv. Brug en blød, tør klud til rengøring. Brug ikke slibende rengøringsmidler eller opløsningsmidler.
  • Ensure the ventilation slots (if any) are not obstructed to prevent overheating.

7. Fejlfinding

If you experience issues with your KL08RF wiring centre, refer to the following common problems and solutions:

ProblemMulig årsagLøsning
No power to the unit (Power LED off)No mains power; loose wiring connection; blown fuse/tripped breaker.Check mains power supply. Verify wiring connections. Check household fuse box/circuit breaker.
Thermostat not communicating with KL08RFThermostat not paired; CO10RF USB coordinator not inserted or faulty; wireless interference; out of range.Re-pair the thermostat. Ensure CO10RF is correctly inserted. Relocate devices to reduce interference. Check distance between devices.
Zone not heating (Zone LED off when it should be on)Faulty actuator; wiring issue to actuator; thermostat not calling for heat.Check actuator functionality. Verify wiring to the actuator. Check thermostat settings and battery.
Pump or Boiler not activatingWiring issue to pump/boiler; pump/boiler fault; no zone calling for heat.Verify pump/boiler wiring. Check pump/boiler for independent operation. Ensure at least one zone is calling for heat.

If the problem persists after attempting these solutions, please contact Salus Controls technical support.

8. Specifikationer

  • Modelnummer: 132801
  • Produktnavn: KL08RF Wireless Wiring Centre
  • Mærke: Salus kontrol
  • zoner: 8 (Wireless)
  • Strømforsyning: 230V AC 50Hz
  • Dimensioner (L x B x H): Approximately 362 x 93 x 69.3 mm (50 x 40 x 18 cm as per product data)
  • Vægt: Approximately 9.07 g (as per product data)
  • Meddelelse: Wireless (via CO10RF USB Coordinator)
  • Device ID (CO10RF example): 001E5E09090A17E9
  • Første tilgængelige: 15. januar 2020
  • Manufacturer Discontinued: Ingen

9. Garanti og support

9.1 Garantioplysninger

The Salus Controls KL08RF Wireless Wiring Centre typically comes with a 5 års garanti from the date of purchase. Please retain your proof of purchase for warranty claims. The warranty covers defects in materials and workmanship under normal use. It does not cover damage caused by improper installation, misuse, accidents, or unauthorized modifications.

9.2 Teknisk support

For technical assistance, troubleshooting beyond this manual, or warranty inquiries, please contact Salus Controls customer support. Refer to the official Salus Controls webwebsted for de mest opdaterede kontaktoplysninger og supportressourcer.

Webwebsted: www.salus-controls.com

Relaterede dokumenter - KL08RF (132801)

Preview SALUS KL08NSB 230V 8 Zones Wiring Centre - Installation and User Guide
Comprehensive guide for the SALUS KL08NSB 230V 8 Zones Wiring Centre, covering installation, technical specifications, wiring, and operation for underfloor heating control systems.
Preview SALUS HTRP-RF(50) Wireless Thermostat Installation Guide | Setup & Pairing
Comprehensive guide for installing and configuring the SALUS HTRP-RF(50) programmable wireless thermostat. Learn about offline/online pairing, connecting to iT600 devices, and advanced settings.
Preview SALUS Controls KL08NSB 8-Zone Wiring Centre: Installation and Operation Manual
Comprehensive guide to the SALUS Controls KL08NSB 8-zone wiring centre, covering installation, technical specifications, and operation for underfloor heating systems. Learn how to connect thermostats, actuators, boilers, and pumps.
Preview SALUS KL08NSB 24V Wiring Centre for Underfloor Heating Systems
Comprehensive guide to the SALUS KL08NSB 24V 8-zone wiring centre, designed for underfloor heating systems. Details installation, technical specifications, wiring connections for thermostats and actuators, boiler and pump control, and advanced features like NSB and delay timers.
Preview SALUS CB500X Control Box Extension: Installation and User Guide
This guide provides detailed information on the SALUS CB500X control box extension module, including its features, technical specifications, safety precautions, and step-by-step installation instructions for underfloor heating systems.
Preview SALUS KL08NSB 24V Wiring Centre: Installation, Wiring, and Operation Guide
Detailed guide for the SALUS KL08NSB 24V 8-zone wiring centre. Covers technical specifications, product compliance, safety information, component descriptions, thermostat connections, and step-by-step installation instructions for underfloor heating systems.